SlideShare a Scribd company logo
See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/356194432
Towards a Wide Area Protection Monitoring System (WAPMS)
Poster · October 2021
CITATIONS
0
READS
5
2 authors:
Some of the authors of this publication are also working on these related projects:
Digital Workbook View project
Social Media Learning View project
Edison Geovanny Guama
Los Andes University (Colombia)
5 PUBLICATIONS   13 CITATIONS   
SEE PROFILE
Iván D. Claros
Axon Group
32 PUBLICATIONS   220 CITATIONS   
SEE PROFILE
All content following this page was uploaded by Edison Geovanny Guama on 15 November 2021.
The user has requested enhancement of the downloaded file.
DEPARTAMENTO DE INGENIERÍA ELÉCTRICA Y ELECTRÓNICA 2018-II
This work presents the preliminary results in the research and development of a Wide Area Protection Monitoring System (WAPMS). This system works as
an information network that automatically collects and analyzes the data contained in the protection devices, which is generally in the standardized
COMTRADE format, this format mainly contains oscillographs with current and voltage signals, and the digital states of the protection functions that were
activated in the event. The proposed system is in charge of collecting information through different communication protocols guaranteeing
interoperability, then it is analyzed determining, among other things, the type and location of the fault. With this information, reports can be generated with
the diagnosis of the system for each substation, which provide the operator with a general insight of the behavior of the system when a fault occurs,
allowing better decisions to be made and guaranteeing a more reliable operation of the power systems.
First, the system is in charge of collecting the information contained in the protection devices by means of
different industrial communication protocols (IEC61850, FTP, TFTP, MODBUS, FastSelMessage), later the data
is organized by means of a set of rules defined by the operator and finally it is stored in a database. Additionally,
a notification via E-Mail is sent when a new event is detected through the SMTP protocol. Finally, the information
can be accessed by any external agent (SCADA, control center Operator) through FTP communication protocol.
Second, the data obtained through the tool are independently analyzed and classified according to the type of
information they contain, e.g. invalid event, operation event, failure event, unknown event. From this information,
a report is generated that contains the type, location and duration of the failure. In addition, the pre-fault, fault,
and post-fault phasors of the event are also displayed. This report is also stored in the database and can be
accessed through the FTP communication protocol.
On the other hand, the tool can be installed in the control center in order to read the information collected in the
adjacent substations as indicated in Figure 2.
CONCLUSIONS AND FUTURE WORK
The preliminary results of a system for automated failure analysis for wide area were presented, which generates a
report with a chronological summary about the impact of the event in different substations. Additionally, the system
has different communication protocols, which guarantees a reliable collection of information regardless of the
device manufacturer.
Currently, our team is working on the research and development of a system for the evaluation of the protection
system. In this case, the objective is for the protection engineer or control center operator to be able to determine
more quickly the behavior of the protection system in the event of a failure in general and make the respective
adjustments in case a unexpected behavior is detected.
On the other hand, with the information processed from each monitored substation, predictive analysis could be
carried out and, among other things, possible hidden failures in the protection devices could be determined, this
would allow operators to anticipate failure events through preventive maintenance.
INTRODUCTION
The large-scale deployment of intelligent devices (IEDs) has generated an increase in the volume of data that
must be analyzed and processed by control center operators. This information is intended to guarantee a reliable
and safe operation of the power system. In particular, the information contained in the protection devices must be
collected and analyzed manually after a failure has occurred; Currently, this task is performed by the protection
engineer, however, due to the large amount of data and technical restrictions, it is an inefficient and
time-consuming process [1]. In addition, these files are currently used as non-operational information, that is,
they do not affect the operation of the electrical system or decision-making in the event of a real-time event.
Generally, the protection devices found in the substation belong to different manufacturers, so additionally,
specific software is needed for each brand to access the information. Therefore, operators are more likely to
make mistakes in the operation, which can cause deterioration in the quality of the energy service to the total loss
of the electrical system (Blackout).
On the other hand, one of the most striking solutions to improve the safety of the electrical system is the
automation in the collection and analysis of faults. This type of solution provides the operator with an assistance
tool for decision making in the event of a failure. In principle, the solution integrates information provided by the
protection devices and make it available to any external agent that requires it. The automation process includes
the collection and organization of files, information processing, analysis, generation and visualization of reports
with the result of the analysis.
SOLUTION
In this work, a protection monitoring system for a wide area is proposed, which facilitates decision-making by the
operator and which can be installed in each substation, based on the analysis of Comtrade standardized format
files [2]. In Figure 1 is shown the general architecture of the Automated Fault analysis which is installed in each
substation.
RESULTS
In Figure 3, a simulation scenario is presented where the information generated specifically by the protection devices
REL670 in Betania and 7SA87 in Muiscas is extracted after a failure has occurred. The main view provides the
operator with an SOE type overview with a general summary with the type of event (operation, fault, unknown), the
location in p.u and the type of short circuit fault.
In this case, the AFA-ACS located in control center can read all the reports generated by the AFA-ACS located in
each substation. This configuration allows a global evaluation of the behavior of the system when an event
occurs. In this case, a personalized report organized chronologically type Sequence of Events (SOE) is
generated. Therefore, the operator has the possibility of performing a faster analysis to restore the service in a
more reliable way. Currently, the effectiveness of the tool is being validated in a real project in Colombia with an
energy company.
REFERENCES
[1] M. Kezunovic, “Practical applications of automated fault analysis”, in PowerCon 2000. 2000 international
Conference on Power System Technology. Proccedings (Cat. No. 00EX409), vol. 2, 2000, pp. 537-557,2014.
[2] Ieee standard common format for transient data exchange(comtrade) for power systems,”IEEE Std
C37.111-1999, pp.1–55, 1999.
[3] S. Das, S. Santoso, A. Gaikwad and M. Patel, "Impedance-based fault location in transmission networks:
theory and application," in IEEE Access, vol. 2, pp. 537-557, 2014
[4] T. Kohonen, M. Schroeder, and T. Huang,Self-Organizing Maps, 012001.
REPORT
OSCILLOGRAPHY
MAIN VIEW
Edison Guamá, Iván Claros
{edison.guama,ivan.claros}@axongroup.com.co
Towards a Wide Area Protection Monitoring System (WAPMS)
R&D Department, Axon Group, Colombia
Figure 1. General Scheme of Automated Fault Analysis
Figure 2. General Scheme WAPMS
Figure 3. View of WAPMS
Monitored
substations
The tool has two ways to compute the fault location;
the first one, is through the Takagi modified Method,
this method eliminate any error caused by
non-homogeneus system. In this case just the data of
one end of the transmission line is used. The second
one is through Two-Ended Fault location Method,
which use waveform data captured at both ends of a
transmission line to estimate the fault location, in this
case this method eliminates any impedance error or
system non-homogeneity [3].
On other hand, the faulted phase identification is
realized through a Kohonen algorithm based on Self
Organizing Map for clustering of classes[4].
In addition to the usual time-signal display of the
measured variables record, the tool is designed to
analyze records from each comtrade file to display
phasor diagrams, bar charts (harmonics analysis)
and impedance diagrams (R/X). Additionally, the
tool offers the possibility to display signals from
different comtrade files to do event comparison.
https://axongroup.com.co
FTP
View publication stats
View publication stats

More Related Content

What's hot

An investigation on the application and challenges for wide area monitoring a...
An investigation on the application and challenges for wide area monitoring a...An investigation on the application and challenges for wide area monitoring a...
An investigation on the application and challenges for wide area monitoring a...
journalBEEI
 
MetConsole® LLWAS (Low Level Wind Shear Alert System)
MetConsole® LLWAS (Low Level Wind Shear Alert System)MetConsole® LLWAS (Low Level Wind Shear Alert System)
MetConsole® LLWAS (Low Level Wind Shear Alert System)
Schneider Electric
 
Smart Dam Monitering & Controling
Smart Dam Monitering & ControlingSmart Dam Monitering & Controling
Smart Dam Monitering & Controling
KrishnenduDatta4
 
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
Satyendra Singh
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
IJERD Editor
 
Development of a software solution for solar pv power systems sizing and moni...
Development of a software solution for solar pv power systems sizing and moni...Development of a software solution for solar pv power systems sizing and moni...
Development of a software solution for solar pv power systems sizing and moni...
simeon Matthew
 
Power system transmission issues and effects
Power system transmission issues and effectsPower system transmission issues and effects
Power system transmission issues and effects
Anand Azad
 
Safety System Modularity
Safety System ModularitySafety System Modularity
Safety System Modularity
Fasiul Alam
 
Kz2418571860
Kz2418571860Kz2418571860
Kz2418571860
IJERA Editor
 
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
IEEEGLOBALSOFTSTUDENTPROJECTS
 
Iec61508 guide
Iec61508 guideIec61508 guide
Iec61508 guide
ronnyalex2013
 
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSNIRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
IRJET Journal
 
Energy conservation in wireless sensor networks
Energy conservation in wireless sensor networksEnergy conservation in wireless sensor networks
Energy conservation in wireless sensor networks
ahmad abdelhafeez
 

What's hot (13)

An investigation on the application and challenges for wide area monitoring a...
An investigation on the application and challenges for wide area monitoring a...An investigation on the application and challenges for wide area monitoring a...
An investigation on the application and challenges for wide area monitoring a...
 
MetConsole® LLWAS (Low Level Wind Shear Alert System)
MetConsole® LLWAS (Low Level Wind Shear Alert System)MetConsole® LLWAS (Low Level Wind Shear Alert System)
MetConsole® LLWAS (Low Level Wind Shear Alert System)
 
Smart Dam Monitering & Controling
Smart Dam Monitering & ControlingSmart Dam Monitering & Controling
Smart Dam Monitering & Controling
 
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
Voltage Stability Assessment using Phasor Measurement Units in Power Network ...
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
Development of a software solution for solar pv power systems sizing and moni...
Development of a software solution for solar pv power systems sizing and moni...Development of a software solution for solar pv power systems sizing and moni...
Development of a software solution for solar pv power systems sizing and moni...
 
Power system transmission issues and effects
Power system transmission issues and effectsPower system transmission issues and effects
Power system transmission issues and effects
 
Safety System Modularity
Safety System ModularitySafety System Modularity
Safety System Modularity
 
Kz2418571860
Kz2418571860Kz2418571860
Kz2418571860
 
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
IEEE 2014 JAVA PARALLEL DISTRIBUTED PROJECTS On false-data-injection-attacks-...
 
Iec61508 guide
Iec61508 guideIec61508 guide
Iec61508 guide
 
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSNIRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
IRJET- A Comprehensive Study of Energy Efficient Algorithms in WSN
 
Energy conservation in wireless sensor networks
Energy conservation in wireless sensor networksEnergy conservation in wireless sensor networks
Energy conservation in wireless sensor networks
 

Similar to Afa wea

IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
IRJET Journal
 
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
Sheikh R Manihar Ahmed
 
Power system automation
Power system automationPower system automation
Power system automation
Abbas Ali
 
ATS @Station
ATS @StationATS @Station
ATS @Station
Hoang Le Van
 
Guideline for the certification of wind turbine service technicians 2015 july
Guideline for the certification of wind turbine service technicians  2015 julyGuideline for the certification of wind turbine service technicians  2015 july
Guideline for the certification of wind turbine service technicians 2015 july
Michael Mattocks
 
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
Michael Mattocks
 
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
ITIIIndustries
 
Practical analysis of the cybersecurity of European smart grids
Practical analysis of the cybersecurity of European smart gridsPractical analysis of the cybersecurity of European smart grids
Practical analysis of the cybersecurity of European smart grids
Sergey Gordeychik
 
intelligent-management-of-electrical-systems-in-industries.docx
intelligent-management-of-electrical-systems-in-industries.docxintelligent-management-of-electrical-systems-in-industries.docx
intelligent-management-of-electrical-systems-in-industries.docx
KondiVinay
 
Control and indicating equipment communicating via the peripheral component i...
Control and indicating equipment communicating via the peripheral component i...Control and indicating equipment communicating via the peripheral component i...
Control and indicating equipment communicating via the peripheral component i...
journalBEEI
 
Sensor Fault Detection in IoT System Using Machine Learning
Sensor Fault Detection in IoT System Using Machine LearningSensor Fault Detection in IoT System Using Machine Learning
Sensor Fault Detection in IoT System Using Machine Learning
IRJET Journal
 
IJSRED-V2I2P15
IJSRED-V2I2P15IJSRED-V2I2P15
IJSRED-V2I2P15
IJSRED
 
IRJET-5G Mobile Technology
IRJET-5G Mobile TechnologyIRJET-5G Mobile Technology
IRJET-5G Mobile Technology
IRJET Journal
 
Easily Accessibility Of Power Plant Data & Reporting.pptx
Easily Accessibility Of Power Plant Data & Reporting.pptxEasily Accessibility Of Power Plant Data & Reporting.pptx
Easily Accessibility Of Power Plant Data & Reporting.pptx
NayanSinhParmar
 
IRJET- Secure Scheme For Cloud-Based Multimedia Content Storage
IRJET-  	  Secure Scheme For Cloud-Based Multimedia Content StorageIRJET-  	  Secure Scheme For Cloud-Based Multimedia Content Storage
IRJET- Secure Scheme For Cloud-Based Multimedia Content Storage
IRJET Journal
 
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
IRJET Journal
 
Annunciator for Hazard Prevention & Temperature Control
Annunciator for Hazard Prevention & Temperature ControlAnnunciator for Hazard Prevention & Temperature Control
Annunciator for Hazard Prevention & Temperature Control
IOSR Journals
 
Dr Dev Kambhampati | Electric Utilities Situational Awareness
Dr Dev Kambhampati | Electric Utilities Situational AwarenessDr Dev Kambhampati | Electric Utilities Situational Awareness
Dr Dev Kambhampati | Electric Utilities Situational Awareness
Dr Dev Kambhampati
 
NIST Guide- Situational Awareness for Electric Utilities
NIST Guide- Situational Awareness for Electric UtilitiesNIST Guide- Situational Awareness for Electric Utilities
NIST Guide- Situational Awareness for Electric Utilities
Dr Dev Kambhampati
 
Fuel Station Monitoring and Automation based on WSN
Fuel Station Monitoring and Automation based on WSN Fuel Station Monitoring and Automation based on WSN
Fuel Station Monitoring and Automation based on WSN
IJECEIAES
 

Similar to Afa wea (20)

IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
IRJET- Oil Tank Prototype based on Wireless Communication-Controller System u...
 
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
 
Power system automation
Power system automationPower system automation
Power system automation
 
ATS @Station
ATS @StationATS @Station
ATS @Station
 
Guideline for the certification of wind turbine service technicians 2015 july
Guideline for the certification of wind turbine service technicians  2015 julyGuideline for the certification of wind turbine service technicians  2015 july
Guideline for the certification of wind turbine service technicians 2015 july
 
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
Guideline for the Chartered Certification WTSR of Wind Turbine Service Techni...
 
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
Complex Measurement Systems in Medicine: from Synchronized Monotask Measuring...
 
Practical analysis of the cybersecurity of European smart grids
Practical analysis of the cybersecurity of European smart gridsPractical analysis of the cybersecurity of European smart grids
Practical analysis of the cybersecurity of European smart grids
 
intelligent-management-of-electrical-systems-in-industries.docx
intelligent-management-of-electrical-systems-in-industries.docxintelligent-management-of-electrical-systems-in-industries.docx
intelligent-management-of-electrical-systems-in-industries.docx
 
Control and indicating equipment communicating via the peripheral component i...
Control and indicating equipment communicating via the peripheral component i...Control and indicating equipment communicating via the peripheral component i...
Control and indicating equipment communicating via the peripheral component i...
 
Sensor Fault Detection in IoT System Using Machine Learning
Sensor Fault Detection in IoT System Using Machine LearningSensor Fault Detection in IoT System Using Machine Learning
Sensor Fault Detection in IoT System Using Machine Learning
 
IJSRED-V2I2P15
IJSRED-V2I2P15IJSRED-V2I2P15
IJSRED-V2I2P15
 
IRJET-5G Mobile Technology
IRJET-5G Mobile TechnologyIRJET-5G Mobile Technology
IRJET-5G Mobile Technology
 
Easily Accessibility Of Power Plant Data & Reporting.pptx
Easily Accessibility Of Power Plant Data & Reporting.pptxEasily Accessibility Of Power Plant Data & Reporting.pptx
Easily Accessibility Of Power Plant Data & Reporting.pptx
 
IRJET- Secure Scheme For Cloud-Based Multimedia Content Storage
IRJET-  	  Secure Scheme For Cloud-Based Multimedia Content StorageIRJET-  	  Secure Scheme For Cloud-Based Multimedia Content Storage
IRJET- Secure Scheme For Cloud-Based Multimedia Content Storage
 
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
Smart Substation with Automatic Monitoring, Smart Controlling and Overload Pr...
 
Annunciator for Hazard Prevention & Temperature Control
Annunciator for Hazard Prevention & Temperature ControlAnnunciator for Hazard Prevention & Temperature Control
Annunciator for Hazard Prevention & Temperature Control
 
Dr Dev Kambhampati | Electric Utilities Situational Awareness
Dr Dev Kambhampati | Electric Utilities Situational AwarenessDr Dev Kambhampati | Electric Utilities Situational Awareness
Dr Dev Kambhampati | Electric Utilities Situational Awareness
 
NIST Guide- Situational Awareness for Electric Utilities
NIST Guide- Situational Awareness for Electric UtilitiesNIST Guide- Situational Awareness for Electric Utilities
NIST Guide- Situational Awareness for Electric Utilities
 
Fuel Station Monitoring and Automation based on WSN
Fuel Station Monitoring and Automation based on WSN Fuel Station Monitoring and Automation based on WSN
Fuel Station Monitoring and Automation based on WSN
 

Recently uploaded

PMSM-Motor-Control : A research about FOC
PMSM-Motor-Control : A research about FOCPMSM-Motor-Control : A research about FOC
PMSM-Motor-Control : A research about FOC
itssurajthakur06
 
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model SafeBangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
bookhotbebes1
 
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdf
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdfPrinciples of Electronic Communication System 4th Edition by Louis Frenzel.pdf
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdf
AeronKimAbel
 
Development of Chatbot Using AI/ML Technologies
Development of  Chatbot Using AI/ML TechnologiesDevelopment of  Chatbot Using AI/ML Technologies
Development of Chatbot Using AI/ML Technologies
maisnampibarel
 
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
VICTOR MAESTRE RAMIREZ
 
RF SPUTTERING.pptx engineering physics..
RF SPUTTERING.pptx engineering physics..RF SPUTTERING.pptx engineering physics..
RF SPUTTERING.pptx engineering physics..
abiwaiting2005
 
Foundation Settlement, effect, causes and solution
Foundation Settlement, effect, causes and solutionFoundation Settlement, effect, causes and solution
Foundation Settlement, effect, causes and solution
Akoladeadebola
 
Introduction to neural network (Module 1).pptx
Introduction to neural network (Module 1).pptxIntroduction to neural network (Module 1).pptx
Introduction to neural network (Module 1).pptx
archanac21
 
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
uayma
 
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
byyi0h
 
Net Zero Case Study: SRK House and SRK Empire
Net Zero Case Study: SRK House and SRK EmpireNet Zero Case Study: SRK House and SRK Empire
Net Zero Case Study: SRK House and SRK Empire
Global Network for Zero
 
Criterion 7 NAAC EED with detailed .pptx
Criterion 7 NAAC EED with detailed .pptxCriterion 7 NAAC EED with detailed .pptx
Criterion 7 NAAC EED with detailed .pptx
MaulikPandya25
 
How to Manage Internal Notes in Odoo 17 POS
How to Manage Internal Notes in Odoo 17 POSHow to Manage Internal Notes in Odoo 17 POS
How to Manage Internal Notes in Odoo 17 POS
Celine George
 
Best Practices for Password Rotation and Tools to Streamline the Process
Best Practices for Password Rotation and Tools to Streamline the ProcessBest Practices for Password Rotation and Tools to Streamline the Process
Best Practices for Password Rotation and Tools to Streamline the Process
Bert Blevins
 
DATA MINING - CHARACTERISTICS and APPLICATION
DATA MINING - CHARACTERISTICS and APPLICATIONDATA MINING - CHARACTERISTICS and APPLICATION
DATA MINING - CHARACTERISTICS and APPLICATION
MD.ANISUR RAHMAN
 
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-IDUNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
GOWSIKRAJA PALANISAMY
 
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulationCS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
amrashbhanuabdul
 
Raw Mix Design for Clinker Manufacturing .pdf
Raw Mix Design for Clinker Manufacturing .pdfRaw Mix Design for Clinker Manufacturing .pdf
Raw Mix Design for Clinker Manufacturing .pdf
srinivasaraonerella1
 
DESIGN OF BEARINGS ANJANEYULU bridge bearing
DESIGN OF BEARINGS ANJANEYULU bridge bearingDESIGN OF BEARINGS ANJANEYULU bridge bearing
DESIGN OF BEARINGS ANJANEYULU bridge bearing
GokulKannan194051
 
Unblocking The Main Thread - Solving ANRs and Frozen Frames
Unblocking The Main Thread - Solving ANRs and Frozen FramesUnblocking The Main Thread - Solving ANRs and Frozen Frames
Unblocking The Main Thread - Solving ANRs and Frozen Frames
Sinan KOZAK
 

Recently uploaded (20)

PMSM-Motor-Control : A research about FOC
PMSM-Motor-Control : A research about FOCPMSM-Motor-Control : A research about FOC
PMSM-Motor-Control : A research about FOC
 
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model SafeBangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
Bangalore @ℂall @Girls ꧁❤ 0000000000 ❤꧂@ℂall @Girls Service Vip Top Model Safe
 
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdf
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdfPrinciples of Electronic Communication System 4th Edition by Louis Frenzel.pdf
Principles of Electronic Communication System 4th Edition by Louis Frenzel.pdf
 
Development of Chatbot Using AI/ML Technologies
Development of  Chatbot Using AI/ML TechnologiesDevelopment of  Chatbot Using AI/ML Technologies
Development of Chatbot Using AI/ML Technologies
 
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
Advances in Detect and Avoid for Unmanned Aircraft Systems and Advanced Air M...
 
RF SPUTTERING.pptx engineering physics..
RF SPUTTERING.pptx engineering physics..RF SPUTTERING.pptx engineering physics..
RF SPUTTERING.pptx engineering physics..
 
Foundation Settlement, effect, causes and solution
Foundation Settlement, effect, causes and solutionFoundation Settlement, effect, causes and solution
Foundation Settlement, effect, causes and solution
 
Introduction to neural network (Module 1).pptx
Introduction to neural network (Module 1).pptxIntroduction to neural network (Module 1).pptx
Introduction to neural network (Module 1).pptx
 
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
一比一原版(cuw文凭证书)美国威斯康星康考迪亚大学毕业证如何办理
 
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
一比一原版(UQ毕业证书)昆士兰大学毕业证如何办理
 
Net Zero Case Study: SRK House and SRK Empire
Net Zero Case Study: SRK House and SRK EmpireNet Zero Case Study: SRK House and SRK Empire
Net Zero Case Study: SRK House and SRK Empire
 
Criterion 7 NAAC EED with detailed .pptx
Criterion 7 NAAC EED with detailed .pptxCriterion 7 NAAC EED with detailed .pptx
Criterion 7 NAAC EED with detailed .pptx
 
How to Manage Internal Notes in Odoo 17 POS
How to Manage Internal Notes in Odoo 17 POSHow to Manage Internal Notes in Odoo 17 POS
How to Manage Internal Notes in Odoo 17 POS
 
Best Practices for Password Rotation and Tools to Streamline the Process
Best Practices for Password Rotation and Tools to Streamline the ProcessBest Practices for Password Rotation and Tools to Streamline the Process
Best Practices for Password Rotation and Tools to Streamline the Process
 
DATA MINING - CHARACTERISTICS and APPLICATION
DATA MINING - CHARACTERISTICS and APPLICATIONDATA MINING - CHARACTERISTICS and APPLICATION
DATA MINING - CHARACTERISTICS and APPLICATION
 
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-IDUNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
UNIT I INCEPTION OF INFORMATION DESIGN 20CDE09-ID
 
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulationCS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
CS8651- Unit 2 - JS.internet programming paper anna university -2017 regulation
 
Raw Mix Design for Clinker Manufacturing .pdf
Raw Mix Design for Clinker Manufacturing .pdfRaw Mix Design for Clinker Manufacturing .pdf
Raw Mix Design for Clinker Manufacturing .pdf
 
DESIGN OF BEARINGS ANJANEYULU bridge bearing
DESIGN OF BEARINGS ANJANEYULU bridge bearingDESIGN OF BEARINGS ANJANEYULU bridge bearing
DESIGN OF BEARINGS ANJANEYULU bridge bearing
 
Unblocking The Main Thread - Solving ANRs and Frozen Frames
Unblocking The Main Thread - Solving ANRs and Frozen FramesUnblocking The Main Thread - Solving ANRs and Frozen Frames
Unblocking The Main Thread - Solving ANRs and Frozen Frames
 

Afa wea

  • 1. See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/356194432 Towards a Wide Area Protection Monitoring System (WAPMS) Poster · October 2021 CITATIONS 0 READS 5 2 authors: Some of the authors of this publication are also working on these related projects: Digital Workbook View project Social Media Learning View project Edison Geovanny Guama Los Andes University (Colombia) 5 PUBLICATIONS   13 CITATIONS    SEE PROFILE Iván D. Claros Axon Group 32 PUBLICATIONS   220 CITATIONS    SEE PROFILE All content following this page was uploaded by Edison Geovanny Guama on 15 November 2021. The user has requested enhancement of the downloaded file.
  • 2. DEPARTAMENTO DE INGENIERÍA ELÉCTRICA Y ELECTRÓNICA 2018-II This work presents the preliminary results in the research and development of a Wide Area Protection Monitoring System (WAPMS). This system works as an information network that automatically collects and analyzes the data contained in the protection devices, which is generally in the standardized COMTRADE format, this format mainly contains oscillographs with current and voltage signals, and the digital states of the protection functions that were activated in the event. The proposed system is in charge of collecting information through different communication protocols guaranteeing interoperability, then it is analyzed determining, among other things, the type and location of the fault. With this information, reports can be generated with the diagnosis of the system for each substation, which provide the operator with a general insight of the behavior of the system when a fault occurs, allowing better decisions to be made and guaranteeing a more reliable operation of the power systems. First, the system is in charge of collecting the information contained in the protection devices by means of different industrial communication protocols (IEC61850, FTP, TFTP, MODBUS, FastSelMessage), later the data is organized by means of a set of rules defined by the operator and finally it is stored in a database. Additionally, a notification via E-Mail is sent when a new event is detected through the SMTP protocol. Finally, the information can be accessed by any external agent (SCADA, control center Operator) through FTP communication protocol. Second, the data obtained through the tool are independently analyzed and classified according to the type of information they contain, e.g. invalid event, operation event, failure event, unknown event. From this information, a report is generated that contains the type, location and duration of the failure. In addition, the pre-fault, fault, and post-fault phasors of the event are also displayed. This report is also stored in the database and can be accessed through the FTP communication protocol. On the other hand, the tool can be installed in the control center in order to read the information collected in the adjacent substations as indicated in Figure 2. CONCLUSIONS AND FUTURE WORK The preliminary results of a system for automated failure analysis for wide area were presented, which generates a report with a chronological summary about the impact of the event in different substations. Additionally, the system has different communication protocols, which guarantees a reliable collection of information regardless of the device manufacturer. Currently, our team is working on the research and development of a system for the evaluation of the protection system. In this case, the objective is for the protection engineer or control center operator to be able to determine more quickly the behavior of the protection system in the event of a failure in general and make the respective adjustments in case a unexpected behavior is detected. On the other hand, with the information processed from each monitored substation, predictive analysis could be carried out and, among other things, possible hidden failures in the protection devices could be determined, this would allow operators to anticipate failure events through preventive maintenance. INTRODUCTION The large-scale deployment of intelligent devices (IEDs) has generated an increase in the volume of data that must be analyzed and processed by control center operators. This information is intended to guarantee a reliable and safe operation of the power system. In particular, the information contained in the protection devices must be collected and analyzed manually after a failure has occurred; Currently, this task is performed by the protection engineer, however, due to the large amount of data and technical restrictions, it is an inefficient and time-consuming process [1]. In addition, these files are currently used as non-operational information, that is, they do not affect the operation of the electrical system or decision-making in the event of a real-time event. Generally, the protection devices found in the substation belong to different manufacturers, so additionally, specific software is needed for each brand to access the information. Therefore, operators are more likely to make mistakes in the operation, which can cause deterioration in the quality of the energy service to the total loss of the electrical system (Blackout). On the other hand, one of the most striking solutions to improve the safety of the electrical system is the automation in the collection and analysis of faults. This type of solution provides the operator with an assistance tool for decision making in the event of a failure. In principle, the solution integrates information provided by the protection devices and make it available to any external agent that requires it. The automation process includes the collection and organization of files, information processing, analysis, generation and visualization of reports with the result of the analysis. SOLUTION In this work, a protection monitoring system for a wide area is proposed, which facilitates decision-making by the operator and which can be installed in each substation, based on the analysis of Comtrade standardized format files [2]. In Figure 1 is shown the general architecture of the Automated Fault analysis which is installed in each substation. RESULTS In Figure 3, a simulation scenario is presented where the information generated specifically by the protection devices REL670 in Betania and 7SA87 in Muiscas is extracted after a failure has occurred. The main view provides the operator with an SOE type overview with a general summary with the type of event (operation, fault, unknown), the location in p.u and the type of short circuit fault. In this case, the AFA-ACS located in control center can read all the reports generated by the AFA-ACS located in each substation. This configuration allows a global evaluation of the behavior of the system when an event occurs. In this case, a personalized report organized chronologically type Sequence of Events (SOE) is generated. Therefore, the operator has the possibility of performing a faster analysis to restore the service in a more reliable way. Currently, the effectiveness of the tool is being validated in a real project in Colombia with an energy company. REFERENCES [1] M. Kezunovic, “Practical applications of automated fault analysis”, in PowerCon 2000. 2000 international Conference on Power System Technology. Proccedings (Cat. No. 00EX409), vol. 2, 2000, pp. 537-557,2014. [2] Ieee standard common format for transient data exchange(comtrade) for power systems,”IEEE Std C37.111-1999, pp.1–55, 1999. [3] S. Das, S. Santoso, A. Gaikwad and M. Patel, "Impedance-based fault location in transmission networks: theory and application," in IEEE Access, vol. 2, pp. 537-557, 2014 [4] T. Kohonen, M. Schroeder, and T. Huang,Self-Organizing Maps, 012001. REPORT OSCILLOGRAPHY MAIN VIEW Edison Guamá, Iván Claros {edison.guama,ivan.claros}@axongroup.com.co Towards a Wide Area Protection Monitoring System (WAPMS) R&D Department, Axon Group, Colombia Figure 1. General Scheme of Automated Fault Analysis Figure 2. General Scheme WAPMS Figure 3. View of WAPMS Monitored substations The tool has two ways to compute the fault location; the first one, is through the Takagi modified Method, this method eliminate any error caused by non-homogeneus system. In this case just the data of one end of the transmission line is used. The second one is through Two-Ended Fault location Method, which use waveform data captured at both ends of a transmission line to estimate the fault location, in this case this method eliminates any impedance error or system non-homogeneity [3]. On other hand, the faulted phase identification is realized through a Kohonen algorithm based on Self Organizing Map for clustering of classes[4]. In addition to the usual time-signal display of the measured variables record, the tool is designed to analyze records from each comtrade file to display phasor diagrams, bar charts (harmonics analysis) and impedance diagrams (R/X). Additionally, the tool offers the possibility to display signals from different comtrade files to do event comparison. https://axongroup.com.co FTP View publication stats View publication stats