26
\$\begingroup\$

I'm planning on using an LM1117 to regulate 5 V to 3.3 V. Looking at (any of the several) data sheets for the LM1117, they recommend 10 µF tantalum capacitors between input and ground and between output and ground.

I understand the need for the capacitors, but it's not clear to me why these should specifically be tantalum. I have a bunch of electrolytic 10 µF capacitors sitting around here, whereas if it does for some reason need to be tantalum, I'll have to order those.

Why are they so specific about using tantalum capacitors?

\$\endgroup\$
9
  • \$\begingroup\$ Could it be that tantalums typically have a higher ESR than electrolytic? \$\endgroup\$
    – Majenko
    Commented Aug 18, 2011 at 10:12
  • \$\begingroup\$ Matt, having read a little more about it, ESR certainly seems likely to be the reason. ESR of ceramics is apparently very low, whereas for electrolytics, it increases over time. If this is indeed the reason, electrolytics should be fine for now - I'm trying something out, not making 10,000 of them. Still, I'd like to know for sure. \$\endgroup\$
    – Jon Bright
    Commented Aug 18, 2011 at 10:28
  • 4
    \$\begingroup\$ Tantalums have a low ESR! \$\endgroup\$ Commented Aug 18, 2011 at 11:42
  • 4
    \$\begingroup\$ @MattYoung Actually yes, it is. Because if someone like you finds something wrong you are able to correct it. It's called "peer review", and it's basically what all the scientific papers go through. In this case the peers are scattered all over the internet. \$\endgroup\$
    – Majenko
    Commented Jul 19, 2014 at 13:57
  • 6
    \$\begingroup\$ @MattYoung And how long do you think that edit would last? Wikipedia isn't the free-for-all you seem to think it is. \$\endgroup\$
    – Majenko
    Commented Jul 19, 2014 at 14:09

3 Answers 3

35
\$\begingroup\$

Tantalum capacitors are completely unnecessary in this application.

  • The only reason for choosing tantalum might be lifetime, and this can be designed for with aluminium wet electrolytic caps. It is assumed from here on that lifetime has been properly designed for and is not an issue.

  • Using a tantalum capacitor as the input capacitor invites capacitor death at any time if the input power rail can have voltage spikes on it from any source. A spike more than a small fraction above a tantalum capacitor's rated value risks it's total destruction in a high energy circuit, such as this one is.

  • The input capacitor is a typical reservoir capacitor, its value is relatively non critical. Tantalum serves no technical purpose here. If ultra low impedance is desired then use of a smaller parallel ceramic is indicated.

  • The output capacitor is NOT a filter capacitor in any traditional sense. Its principal role is to provide loop stability for the regulator. (An eg 10 ohm resistor could be placed in series with the capacitor without impeding its functionality. No normal filter cap would tolerate this without impaired functionality).

  • The characteristics of aluminum wet electrolytic capacitors of the correct capacitance and voltage rating are well suited to the output capacitor's role. There is no reason to not use them there. This 7 cent capacitor pricing / general data / datasheet would be an acceptable choice in many applications. (Longer lifetime applications may indicate 1 2000 hour/105C part).


The LM1117 datasheet provides clear guidance on the essential and desirable characteristics of the input and output capacitors. Any capacitor which meets these specifications is suitable. Tantalum is an OK choice but is not the best choice. There are various factors and cost is one. Tantalum offers OK cost per capability at capacitances from about 10 uF up. The output capacitor is "safe" against spikes in most cases. The input capacitor is at risk from "bad behavior" from other parts of the system. Spikes above rated value will produce a (literally) flaming melt down. (Smoke, flame, noise, bad smell and explosion all optional -
I have seen one tantalum cap do all of these in turn :-))

Input capacitor

The input capacitor is not overly critical when the regulator is fed from an already well decoupled system bus. Under the diagram on the front page they note "Required if the regulator is located far from the power supply filter" - to which you could add "or another well decoupled portion of the supply". ie capacitors used for decoupling in general may make another one here redundant. The output capacitor is more crucial.

Output capacitor

Many modern low drop out high performance regulators are unconditionally unstable as supplied. To provide loop stability they require an output capacitor which has both capacitance and ESR in selected ranges. Meeting these conditions is essential for stability under all load conditions.

Output capacitance required for stability: Stability requires the output output load capacitor to be >= 10 uF when the Cadj pin does not have an added capacitor to ground and >= 20 uF when Cadj has an added bypass capacitor. Higher capacitances are also stable. This requirement could be met by an aluminum wet electrolytic cap or a ceramic cap. As wet electrolytics are generally wide tolerance (up to +100%/-50% if not other wise specified) a 47 uF aluminum wet electrolytic would provide adequate capacitance here even when Cadj was bypassed. BUT it may or may not meet the ESR spec.

Output capacitor ESR required for stability:

ESR is a "Goldilocks requirement" :-) - not too much and not too little.
Required ESR is stated as

    0.3 ohm <= ESR <= 22 ohm.

This is an extremely wide and unusual requirement. Even quite modest ripple currents in this capacitor would induce far larger than acceptable voltage variations. It's clear that they do not expect high ripple currents and that the capacitor's role is primarily related to loop stability than to noise control per se. Note that "old school" regulators such as eg LM340 / LM7805 often specified no output capacitor or perhaps a 0.1 uF. For example the LM340 datasheet here says "**Although no output capacitor is needed for stability, it does help transient response. (If needed, use 0.1 µF, ceramic disc)".

A tantalum capacitor is not required to meet this specification.
A wet aluminum capacitor will meet this spec with ease. Here are some typical new maximum ESRs for new aluminum wet electrolytic capacitors. The first group are capacitors that might be used in practice in this application at the low end of the capacitance range. The 10 uF, 10V is about half the allowed ESr - perhaps a bit close for comfort across lifetime. The second group are what would be used with Cadj bypassed and could be used anyway - ESRs are far away from limits in both directions. The third group are capacitors chosen to approach the lower limit (and they will get higher resistance = better with age). The 100 uF 63V pushes the lower limit - but there would be no need to use a 63V part here, and it will get higher (= better) with age. .

  • 10uF, 10V - 10 ohm
    10 uF, 25V - 5.3 ohm

  • 47uF, 10V - 2.2 ohm
    47 uF, 16V - 1.6 ohm 47 uF, 25 V, 1.2 ohm

  • 470 uF, 10V - 024ohm
    220uF, 25V - 0.23 ohm
    100 uF, 63V - 0.3 ohm


They say in the LM1117 datasheet

  • 1.3 Output Capacitor

The output capacitor is critical in maintaining regulator stability, and must meet the required conditions for both minimum amount of capacitance and ESR (Equivalent Series Resistance).

The minimum output capacitance required by the LM1117 is 10µF, if a tantalum capacitor is used. Any increase of the output capacitance will merely improve the loop stability and transient response.

The ESR of the output capacitor should range between 0.3Ω - 22Ω. In the case of the adjustable regulator, when the CADJ is used, a larger output capacitance (22µf tantalum) is required

ESR is crucial


ADDED - notes

SBCasked:

I've read this so many times - "maintain regulator stability".
What would be an example of an unstable regulator?
Would the output oscillate with high ripple or be undefined or what exactly would happen?

Regulator instability, in my experience, (and as you'd expect) results in the regulator oscillating, with large level and often high frequency signal at the output and a DC voltage measured with a non-RMS meter that appears to be stable DC at an incorrect value.

The following is comment on what you may see in typical circumstances - actual results vary widely but this is a guide.
Look at the output with an oscilloscope and you may see an eg 100 kHz semi sine wave of 100's of mV to some Volts of amplitude on a nominal 5VDC output.

Depending on feedback parameters you might get low frequency oscillation, slow enough to see as variations on a "DC" meter and you might get more like MHz signals.
I'd expect:
(a) very slow changes to be more liable to be high amplitude (as it suggests that the system is chasing its tail in such a way that it is almost in regulation and that corrective feedback is not bringing it rapidly into line, and
(b) MHz level oscillation to be more liable to be lower than usual amplitude as it suggests that slew rate of the gain path is a major factor in response speed. BUT anything can happen.

Also, how exactly does the ESR come into play here?
A naive passerby like myself would expect lower series resistance to be better.

The intuitive and the logical do not always match.
A regulator is essentially a feedback controlled power amplifier.
If the feedback is negative overall the system is stable and the output is DC.
If the net loop feedback is positive you get oscillation.
The overall feedback is described by a transfer function involving the components involved. You can look at stability from the point of view of eg Nyquist stability criteria or (related) no poles on right half plane and all poles inside unit circle or ... agh!. It's adequate to say that the feedback from output to input does not reinforce oscillation and that a resistance that is too large or too small may lead to an overall reinforcement when considered as part of the overall system.
Simple, useful.
Only slightly more complex - good
Sueful - stack exchange

Useful

Lots of related pictures

And one final note, did you refer to the ripple voltage on the cap being large (even for small currents) as an inherent issue due to the small size? (i.e. Vc = integral of current over capacitance?)

They say " ... 0.3 ohm <= ESR <= 22 ohm ..."
If you has an ESR of 10 Ohms say, then every mA of ripple current will cause 10 mV of voltage variation across the capacitor. 10 mA of ripple current = 100 mV of voltage variation and you'd be very unhappy with your regulator. The active regulator can work to reduce this ripple, but it is nice to not have your filter capacitor adding to the problem you want it to fix.


Added 2023: Aluminium electrolytic capacitor lifetime

Nick asked:

12000 hours sounds like a lot, but it's less than 18 months continuous use. 1000 hours of the 7 cent part suggested is well under two months. Tantalum cap lifetime can be decades. So this could be a consideration.

Aluminium electrolytic capacitor lifetimes double for every 10 degrees C (or K :-) ) reduction in operating temperature. The reason for using eg 105C rated parts is usually not so that they can be operated at near 100C, but so that they have much longer lifetimes at lower temperatures.
eg a 12,000 hours 105 C rated capacitor operated at a temperature of 55 C will have a rated lifetime of 12,000 x 2^((105-55)/10)) =~380,000 hours or about 40+ years.
Odds are that's overkill.
Even a 2000 hour cap gives 7 years. Or 14 years at 45 C.

The citd 7 cent part was probably rated at 1000 hours and 85 C. At say 45C that gives 1000 x 2^((85-45)/10) = 16000 hours or about 2 years.
Less than would usually be desirable.
At 25C it gives 8 years.
This is of course very approximate and a factor of two either way may be possible.


Variation of ceramic capacitor capacitance with temperature and voltage.

A point worth noting. Using a ceramic capacitor in place of the tantalum may be safer. BUT note that ceramic capacitor capacitance variation with temperature varies very substantially with type.

See excellent Analog - Temperature and Voltage Variation of Ceramic Capacitors, and

Digikey - Effects of Temperature Change on MLCCs and

Taiyo Yuden

\$\endgroup\$
8
  • 1
    \$\begingroup\$ Thank you for the extremely detailed and helpful answer. I'm still a little puzzled about why they specifically call out tantalum so much, but your answer makes clear that I can overlook this. \$\endgroup\$
    – Jon Bright
    Commented Aug 18, 2011 at 12:21
  • 1
    \$\begingroup\$ I've read this so many times - "maintain regular stability". What would be an example of an unstable regulator? Would the output oscillate with high ripple or be undefined? What exactly would happen? Also, how exactly does the ESR come into play here? A naive passerby like myself would expect lower series resistance to be better. And one final note, did you refer to the ripple voltage on the cap being large (even for small currents) as an inherent issue due to the small size? (i.e. Vc = integral of current over capacitance?) \$\endgroup\$
    – sherrellbc
    Commented Jul 19, 2014 at 14:53
  • \$\begingroup\$ Most capacitors don't behave like a single cap in series with a single resistor, but rather as a huge network of interconnected resistors and capacitors. If a 100uF cap behaved as a series-parallel combination containing a series combination of an ideal 0.1uf cap and a 0.001 ohm ESR in parallel, and a series combination of an ideal 99.9uF cap and a 100ohm resistor, how would a data sheet be expected to report the ESR of such a cap? \$\endgroup\$
    – supercat
    Commented Jul 19, 2014 at 17:52
  • 2
    \$\begingroup\$ @sherrellbc - Regulator instability, in my experience, (and as you'd expect) results in the regulator oscillating, with large level and often high frequency signal at the output and a DC voltage measured with a non-RMS meter that appears to be stable DC at an incorrect value. The following is what you may see in typical circumstances - actual results vary widely but this is a guide. Look at the output with an oscilloscope and you may see an eg 100 kHz semi sine wave of 100's of mV to some Volts of amplitude on a nominal 5VDC output. ... \$\endgroup\$
    – Russell McMahon
    Commented Jul 20, 2014 at 0:23
  • \$\begingroup\$ ... Depending on feedback parameters you might get low frequency oscillation, slow enough to see as variations on a "DC" meter and you might get more like MHz signals. I'd expect: (a) very slow changes to be more liable to be high amplitude (as it suggests that the system is chasing its tail in such a way that it is almost in regulation and that corrective feedback is not bringing it rapidly into line, and (b) MHz level oscillation to be more liable to be lower than usual amplitude as it suggests that slew rate of the gain path is a major factor in response speed. BUT anything can happen. \$\endgroup\$
    – Russell McMahon
    Commented Jul 20, 2014 at 0:28
9
\$\begingroup\$

I found an interesting reference in TI's LM3940 datasheet (A 5V to 3.3V LDO).

Tantalums were specified because Electrolytic can have their ESR increase up to 30x on very low temps.
It is possible to connect a small tantalum in parallel to a large electrolytic if cost is an issue.

ESR LIMITS: The ESR of the output capacitor will cause loop instability if it is too high or too low. The acceptable range of ESR plotted versus load current is shown in Figure 19. It is essential that the output capacitor meet these requirements, or oscillations can result.
Figure 19. ESR Limits
It is important to note that for most capacitors, ESR is specified only at room temperature. However, the designer must ensure that the ESR will stay inside the limits shown over the entire operating temperature range for the design. For aluminum electrolytic capacitors, ESR will increase by about 30X as the temperature is reduced from 25°C to −40°C. This type of capacitor is not well-suited for low temperature operation. Solid tantalum capacitors have a more stable ESR over temperature, but are more expensive than aluminum electrolytics. A cost-effective approach sometimes used is to parallel an aluminum electrolytic with a solid Tantalum, with the total capacitance split about 75/25% with the Aluminum being the larger value. If two capacitors are paralleled, the effective ESR is the parallel of the two individual values. The “flatter” ESR of the Tantalum will keep the effective ESR from rising as quickly at low temperatures.

\$\endgroup\$
1
2
\$\begingroup\$

Electolytics have poor high frequency performance compared to tantalums. With the price of tantalum these days I would recommend using one of your electrolytics with a small ceramic capacitor in parallel - say 100nF. It depends on what you are powering but it's not usually all that critical unless ripple and transient response are especially critical for you.

\$\endgroup\$
3
  • \$\begingroup\$ people get in a mindset backwater on occasion - aluminium* electrolytic bad - tantalum good - must use tantalum .. . I'd be pleased to hear anyone critique my reply on technical grounds. If I've missed something or made a significantly incorrect technical assertion then by all means say. But, I don't believe so. * - I've now spelt aluminium "correctly" as I see you are in UK :-). Flame shields up. \$\endgroup\$
    – Russell McMahon
    Commented Aug 18, 2011 at 12:33
  • 1
    \$\begingroup\$ @Russell McMahon - Huh? (1) I posted my answer before you so I wasn't criticising. (2) We seem to agree anyway! (3) Aluminum capacitors are much much worse than aluminium :) \$\endgroup\$
    – MikeJ-UK
    Commented Aug 18, 2011 at 12:44
  • \$\begingroup\$ mea culpa :-( - I mixed up the comment maker with the questioner - comment was meant to go on the end of my post after Jon's comment :-). I wasn't criticising you - sorry if it seemed that way. I meant to comment on Jon's query why they would spec tantalum given the apparent lack of need for it. Sorry again. \$\endgroup\$
    – Russell McMahon
    Commented Aug 18, 2011 at 13:18

Not the answer you're looking for? Browse other questions tagged or ask your own question.