[Balance of required dose and image quality in digital radiography]
- PMID: 18259724
- DOI: 10.1007/s00117-008-1617-x
[Balance of required dose and image quality in digital radiography]
Abstract
Projection radiography is in an advanced stage of progressive transition from conventional screen-film imaging to digital image acquisition modalities. The radiographic technique, including examination parameters such as tube voltage, tube current and filtration has frequently been adopted from screen-film technology. Digital systems, however, are characterized by their flexibility as the dose can be reduced at the expense of image quality and vice versa. The imaging parameters need to be individually optimized according to the best performance of a system. The traditional means of dose adjustment, such as positioning and collimation, are as valid for digital techniques as they were for conventional techniques. Digital techniques increasingly offer options for dose reduction. At the same time there is a risk to accidentally substantially increase patient dose due to the lack of visual control. Therefore, the implementation of dose indicators and dose monitoring is mandatory for digital radiography. The use of image quality classes according to the dose requirements of given clinical indications are a further step towards modern radiation protection.
Similar articles
-
[Modern techniques for dose reduction in computed tomography imaging].Praxis (Bern 1994). 2013 Jul 3;102(14):865-8. doi: 10.1024/1661-8157/a001352. Praxis (Bern 1994). 2013. PMID: 23823685 Review. German.
-
Beware the mask.J Am Coll Radiol. 2013 Feb;10(2):149-52. doi: 10.1016/j.jacr.2012.10.012. J Am Coll Radiol. 2013. PMID: 23374695 Review. No abstract available.
-
Update on the biological effects of ionizing radiation, relative dose factors and radiation hygiene.Aust Dent J. 2012 Mar;57 Suppl 1:2-8. doi: 10.1111/j.1834-7819.2011.01665.x. Aust Dent J. 2012. PMID: 22376091 Review.
-
Digital radiography: the balance between image quality and required radiation dose.Eur J Radiol. 2009 Nov;72(2):202-8. doi: 10.1016/j.ejrad.2009.05.060. Epub 2009 Jul 22. Eur J Radiol. 2009. PMID: 19628349 Review.
-
Effect of x-ray tube potential on image quality and patient dose for lumbar spine computed radiography examinations.Australas Phys Eng Sci Med. 2005 Dec;28(4):216-22. doi: 10.1007/BF03178721. Australas Phys Eng Sci Med. 2005. PMID: 16506618
Cited by
-
[Dose reduction and adequate image quality in digital radiography: a contradiction?].Radiologe. 2012 Oct;52(10):898-904. doi: 10.1007/s00117-012-2337-9. Radiologe. 2012. PMID: 22986575 German.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources