Relay modules are available for directly connecting high power loads to the MX-System, such as asynchronous motors, lighting, or electric heating. Each of these modules bring multiple functions together in one housing unit and continuously monitors the current. If a fuse is tripped, it can simply be replaced via the flap on the side of the housing. You can find all information on control cabinet-free automation with our MX-System here: https://bit.ly/3Rr6Z50 #beckhoff #automation #mxsystem #engineering #technology
Beckhoff Automation sub-Saharan Africa’s Post
More Relevant Posts
-
Discover the power of valve terminals! 🚀 Combining individual valves into valve terminals offers numerous benefits including reduced cabling, faster actuation, and minimal installation space. Plus, with fieldbus communication, they easily integrate into any system and can be remotely controlled. 💡 Simplify your setup and boost efficiency with our valve terminals, browse them here ➡️ https://lnkd.in/eWJH5P7v #Automation #Engineering #Efficiency #ValveTerminals
To view or add a comment, sign in
-
Global Material Handling & Intralogistics Manager, Solving Automation challenges in Warehouse & Distribution Logistics
Flexible automation by eliminating the cabinet and putting all automation on the equipment. Learn more about Beckhoff's MX-System for cabinet-free automation. #poweredbyMHI #intralogistics #Beckhoff #EtherCAT
The system modules for our MX-System distribute power and allow the system to connect to fieldbuses. The portfolio consists of modules for supplying and forwarding data and voltage, power units, switches, and modules that provide an uninterruptible power supply. You can find out everything you need to know about control cabinet-free automation with our MX-System here: https://bit.ly/3Rr6Z50 #beckhoff #automation #mxsystem #engineering #technology
The MX-System series | Episode 4: The system modules
To view or add a comment, sign in
-
Power Conversion Perfected: Unleash the Potential of Your Electrical Systems with our Frequency Transformer! #FrequencyTransformer #PowerConversion #Efficiency #Reliability #Innovation #ElectricalEngineering #IndustrialAutomation #RenewableEnergy #Telecommunications #Manufacturing #CuttingEdgeTechnology #EngineeringSolutions
To view or add a comment, sign in
-
-
Do you know about our Tandem AFCI residential breaker? Feed two circuits with the same one-inch device! Use half of the space and half the time! And it has unique features that enable a better and safer installation. Watch Dave’s video to learn more!
Welcome back to the 180°! In this edition, we are excited to discuss the relaunch of the Tandem Combination Arc Fault Circuit Breaker by Siemens. This innovative solution is designed to support the new construction and renovation residential markets by decreasing total labor time. With its advanced troubleshooting features, installers can leave job sites with complete confidence in their work. Check out our latest post to learn more about this game-changing technology and how it puts the customer first. Don't forget to use the hashtags #tandem, #innovation, #customerfirst, and #siemens to join the conversation. Thanks for tuning in!
To view or add a comment, sign in
-
3 Steps to Selecting the Right AC Drive STEP 1 - Select The Right AC Drive A. Determine motor voltage, horsepower and full-load amperage B. Select your control mode Choose the control mode that fits your application and Variable torque applications such as fans and pumps work fine with V/Hz control mode as do most general purpose constant torque applications such as conveyors that aren’t going much slower than base speed. Applications that require 100% or close to 100% torque through their speed range should use sensorless vector or FOC modes. Torque control mode is used when the motor torque will be controlled as opposed to speed. STEP 2 - Select the Proper Rating A. Determine motor full load amperage (FLA) Motor FLA is located on the nameplate of the motor. B. Determine overload requirements Many applications experience temporary overload conditions due to starting requirements or impact loading. Most AC drives are designed to operate at 150% overload for 60 seconds. If the application requires an overload greater than 150% or longer than 60 seconds, the AC drive must be oversized. C. Installation altitude AC drives rely upon the cooling properties of air for cooling. As the altitude increases, the air becomes less dense. This decrease in air density decreases the cooling properties of the air. D. Determine max enclosure internal temp AC drives generate a significant amount of heat and will cause the internal temperature of an enclosure to exceed the rating of the AC drive. Enclosure ventilation and/or cooling may be required. Ambient temperature measurements should be required. STEP 3 - Options, Options, and more Options A. Input fuses Input fuses protect the AC drive from excessive input current due to line surges, short circuits, and ground faults. They are recommended for all installations and may be required for UL-listed installations. Input fuse kits and replacement fuses are available for AC drives. B. Input line reactor Input line reactors protect the AC drive from transient overvoltage conditions, typically caused by utility capacitor switching. The input line reactor also reduces the harmonics associated with AC drives. Input line reactors are recommended for all installations. C.Input EMI filter Input EMI filters reduce electromagnetic interference or noise on the input side of the inverter. D. Output line reactor Output line reactors protect the motor insulation against drive short circuits and IGBT reflective wave damage. Output line reactors also “smooth” the motor current waveform, allowing the motor to run cooler. The line reactor can be used for either input or output applications. Output line reactors are recommended for operating “noninverter-duty” motors and when the length of wiring between the AC drive and motor is longer than the recommended max length of a given motor model. Inverter-duty rated motors support longer lead length than do non-inverter duty motors. E. Dynamic braking #Driveselection
To view or add a comment, sign in
-
The flow rates in each individual cooling circuit have a major influence on the temperature control. Huracan Flow Control helps you to measure this in each cooling circuit and is not only giving alarm signals, but also processes all data from the measurements. Huracan Flow Control is characterized by its contactless measuring principle and its intuitive control, which is based on the latest industry standards, ready for Industry 4.0. www.rtc-tec.com www.rtc-tec.com/huracan/ www.rtc-couplings.com/en/ #engineering #automation #digitization #huracan #injectionmoulding #moldmaker #moulding #rtccouplings #rtctec #opportunities #technology #userexperience #Industry4
To view or add a comment, sign in
-
-
Senior Electrical Engineer at Hallam-ICS | Improving MEP installation and upgrades through thoughtful design | Professional Engineering Consulting
This was a lot of fun to put together, and to share some of the really informative work that's already out there. Have you been having issues with VFD-controlled motors? Ghost trips? Motor failures? Read on, or send me a message! #vfd #inspiredengineering
In this blog, Jeff Babineaux, PE talks about demystifying VFD cable requirements, standards, benefits, and drawbacks. Learn how VFD cables solve problems and why they are essential. #vfd #variablefrequencydrive #engineering Akribis Systems Inc. USA HVH Industrial Solutions #NFPA #NEC #IEEE https://hubs.li/Q02vTykk0
To view or add a comment, sign in
-
Delighted to present a simple electrical diagram representation of a motor starter integrating a selector switch and a relay, with the concepts of normally open (NO) and normally closed (NC) contacts, in use to control the two motors individually and simultaneously. This streamlined approach in the electrical diagram enhances efficiency and reliability. This can be further automated using a timer-relay, which plays an pivotal role in the automation world in industries and energy stations. Proud to contribute to cutting-edge solutions in the field. #ElectricalEngineering #electricaldesign #motorstarter #automation
To view or add a comment, sign in
-
The integration of power electronic systems has increased disproportionately. In order to achieve the global, climate policy goals, in this dynamic industry it is necessary to increasingly use frequency converter-controlled drive systems, that are particularly energy-efficient and flexible. We have an extensive portfolio of #reactors and #filters ensuring that drive technology works reliably, trouble-free and efficiently in the context of Industry 4.0. With the help of our proprietary calculation software #taid, we develop ideal components for the EMC-compliant design of a frequency converter-controlled drive system. 👉 https://bit.ly/475QrX6 #drivetechnology #emifilters #chokes #industry40 #industrie40
Failure-free and efficient drive systems | BLOCK
block.eu
To view or add a comment, sign in