Timeline for Triac misfires because of noise from inductive loads
Current License: CC BY-SA 3.0
6 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
Apr 13 at 4:46 | comment | added | Jaimin | Triac have dimming light and in same board i m using hum free fan and using 4 relay for 5 step fan , Whenever , Triac dimming light on below 100 % , that time i do the step down or up fan , triac dimming light flashes for franction of second , is there any solution for that ? | |
Apr 12 at 12:30 | comment | added | Jaimin | I have the same issue , I m using BTA41-600B , is there any component should replace this to solve the problem , as considered snubber less triac @gutisg | |
Feb 17, 2018 at 12:11 | comment | added | Ujjwal Syal | So I ran the experiment. The snubber neighter works across triac, nor across line and neutral. Any ideas? | |
Feb 14, 2018 at 10:35 | comment | added | Ujjwal Syal | I did some reading and I think this will work. But as per my reading, what I understood was that if I put snubber across triac then the triac stays protected but chances are that the LED light will allow the snubber charge to drain and will give flash. If I put snubber across the load, then the LED won't flash but triac stays at risk due to transient noises. So what I was thinking was, what If i put a snubber across line and neutral, close to the triacs and their outputs??? That should solve for both cases, right? | |
Feb 13, 2018 at 18:42 | review | First posts | |||
Feb 13, 2018 at 19:00 | |||||
Feb 13, 2018 at 18:41 | history | answered | gutisg | CC BY-SA 3.0 |