-
Quantitative phase imaging via a multimode fiber
Authors:
Aleksandra Ivanina,
Maxim Marshall,
Ksenia Abrashitova,
Tristan van Leeuwen,
Lyubov V. Amitonova
Abstract:
Label-free quantitative phase imaging is a vital tool for optical microscopy and metrology applications. A hair-thin multimode fiber stands out as a very attractive platform for minimally invasive imaging. Here we propose and experimentally demonstrate a non-interferometric non-iterative approach for high-speed high-resolution label-free quantitative phase imaging via a multimode fiber, unlocking…
▽ More
Label-free quantitative phase imaging is a vital tool for optical microscopy and metrology applications. A hair-thin multimode fiber stands out as a very attractive platform for minimally invasive imaging. Here we propose and experimentally demonstrate a non-interferometric non-iterative approach for high-speed high-resolution label-free quantitative phase imaging via a multimode fiber, unlocking multiple applications in life science and bioimaging.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
Experimental Validation of Ultrasound Beamforming with End-to-End Deep Learning for Single Plane Wave Imaging
Authors:
Ryan A. L. Schoop,
Gijs Hendriks,
Tristan van Leeuwen,
Chris L. de Korte,
Felix Lucka
Abstract:
Ultrafast ultrasound imaging insonifies a medium with one or a combination of a few plane waves at different beam-steered angles instead of many focused waves. It can achieve much higher frame rates, but often at the cost of reduced image quality. Deep learning approaches have been proposed to mitigate this disadvantage, in particular for single plane wave imaging. Predominantly, image-to-image po…
▽ More
Ultrafast ultrasound imaging insonifies a medium with one or a combination of a few plane waves at different beam-steered angles instead of many focused waves. It can achieve much higher frame rates, but often at the cost of reduced image quality. Deep learning approaches have been proposed to mitigate this disadvantage, in particular for single plane wave imaging. Predominantly, image-to-image post-processing networks or fully learned data-to-image neural networks are used. Both construct their mapping purely data-driven and require expressive networks and large amounts of training data to perform well. In contrast, we consider data-to-image networks which incorporate a conventional image formation techniques as differentiable layers in the network architecture. This allows for end-to-end training with small amounts of training data. In this work, using f-k migration as an image formation layer is evaluated in-depth with experimental data. We acquired a data collection designed for benchmarking data-driven plane wave imaging approaches using a realistic breast mimicking phantom and an ultrasound calibration phantom. The evaluation considers global and local image similarity measures and contrast, resolution and lesion detectability analysis. The results show that the proposed network architecture is capable of improving the image quality of single plane wave images on all evaluation metrics. Furthermore, these image quality improvements can be achieved with surprisingly little amounts of training data.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Time-Resolved Reconstruction of Motion, Force, and Stiffness using Spectro-Dynamic MRI
Authors:
Max H. C. van Riel,
Tristan van Leeuwen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Measuring the dynamics and mechanical properties of muscles and joints is important to understand the (patho)physiology of muscles. However, acquiring dynamic time-resolved MRI data is challenging. We have previously developed Spectro-Dynamic MRI which allows the characterization of dynamical systems at a high spatial and temporal resolution directly from k-space data. This work presents an extend…
▽ More
Measuring the dynamics and mechanical properties of muscles and joints is important to understand the (patho)physiology of muscles. However, acquiring dynamic time-resolved MRI data is challenging. We have previously developed Spectro-Dynamic MRI which allows the characterization of dynamical systems at a high spatial and temporal resolution directly from k-space data. This work presents an extended Spectro-Dynamic MRI framework that reconstructs 1) time-resolved MR images, 2) time-resolved motion fields, 3) dynamical parameters, and 4) an activation force, at a temporal resolution of 11 ms. An iterative algorithm solves a minimization problem containing four terms: a motion model relating the motion to the fully-sampled k-space data, a dynamical model describing the expected type of dynamics, a data consistency term describing the undersampling pattern, and finally a regularization term for the activation force. We acquired MRI data using a dynamic motion phantom programmed to move like an actively driven linear elastic system, from which all dynamic variables could be accurately reconstructed, regardless of the sampling pattern. The proposed method performed better than a two-step approach, where time-resolved images were first reconstructed from the undersampled data without any information about the motion, followed by a motion estimation step.
△ Less
Submitted 11 October, 2023;
originally announced October 2023.
-
Maximum-likelihood estimation in ptychography in the presence of Poisson-Gaussian noise statistics
Authors:
Jacob Seifert,
Yifeng Shao,
Rens van Dam,
Dorian Bouchet,
Tristan van Leeuwen,
Allard P. Mosk
Abstract:
Optical measurements often exhibit mixed Poisson-Gaussian noise statistics, which hampers image quality, particularly under low signal-to-noise ratio (SNR) conditions. Computational imaging falls short in such situations when solely Poissonian noise statistics are assumed. In response to this challenge, we define a loss function that explicitly incorporates this mixed noise nature. By using maximu…
▽ More
Optical measurements often exhibit mixed Poisson-Gaussian noise statistics, which hampers image quality, particularly under low signal-to-noise ratio (SNR) conditions. Computational imaging falls short in such situations when solely Poissonian noise statistics are assumed. In response to this challenge, we define a loss function that explicitly incorporates this mixed noise nature. By using maximum-likelihood estimation, we devise a practical method to account for camera readout noise in gradient-based ptychography optimization. Our results, based on both experimental and numerical data, demonstrate that this approach outperforms the conventional one, enabling enhanced image reconstruction quality under challenging noise conditions through a straightforward methodological adjustment.
△ Less
Submitted 11 October, 2023; v1 submitted 3 August, 2023;
originally announced August 2023.
-
WaRIance: wavefield reconstruction inversion with stochastic variable projection
Authors:
Gabrio Rizzuti,
Tristan van Leeuwen
Abstract:
We propose a variation on wavefield reconstruction inversion for seismic inversion, which takes advantage of randomized linear algebra as a way to overcome the typical limitations of conventional inversion techniques. Consequently, we can aim both to robustness towards convergence stagnation and large-sized 3D applications. The central idea hinges on approximating the optimal slack variables invol…
▽ More
We propose a variation on wavefield reconstruction inversion for seismic inversion, which takes advantage of randomized linear algebra as a way to overcome the typical limitations of conventional inversion techniques. Consequently, we can aim both to robustness towards convergence stagnation and large-sized 3D applications. The central idea hinges on approximating the optimal slack variables involved in wavefield reconstruction inversion via a low-rank stochastic approximation of the wave-equation error covariance. As a result, we obtain a family of inversion methods parameterized by a given model covariance (suited for the problem at hand) and the rank of the related stochastic approximation sketch. The challenges and advantages of our proposal are demonstrated with some numerical experiments.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
A note on extended full waveform inversion
Authors:
Tristan van Leeuwen
Abstract:
Full waveform inversion (FWI) aims at estimating subsurface medium properties from measured seismic data. It is usually cast as a non-linear least-squares problem that incorporates uncertainties in the measurements. In exploration seismology, extended formulations of FWI that allow for uncertaties in the physics have been proposed. Even when the physics is modelled accurately, these extensions hav…
▽ More
Full waveform inversion (FWI) aims at estimating subsurface medium properties from measured seismic data. It is usually cast as a non-linear least-squares problem that incorporates uncertainties in the measurements. In exploration seismology, extended formulations of FWI that allow for uncertaties in the physics have been proposed. Even when the physics is modelled accurately, these extensions have been shown to be beneficial because they reduce the non-lineary of the resulting data-fitting problem. In this note, I derive an alternative (but equivalent) formulation of extended full waveform inversion. This re-formulation takes the form of a conventional FWI formulation that includes a medium-dependent weight on the residuals. I discuss the implications of this re-formulation and illustrate its properties with a simple numerical example.
△ Less
Submitted 31 March, 2019;
originally announced April 2019.
-
Simultaneous measurement of localized diffusion and flow using optical coherence tomography
Authors:
Nicolás Weiss,
Ton G. van Leeuwen,
Jeroen Kalkman
Abstract:
We report on the simultaneous and localized measurements of the diffusion coefficient and flow velocity based on the normalized autocorrelation function using optical coherence tomography (OCT). Our results on a flowing solution of polystyrene spheres show that the flow velocity and the diffusion coefficient can be reliably estimated in a regime determined by the sample diffusivity, the local flow…
▽ More
We report on the simultaneous and localized measurements of the diffusion coefficient and flow velocity based on the normalized autocorrelation function using optical coherence tomography (OCT). Our results on a flowing solution of polystyrene spheres show that the flow velocity and the diffusion coefficient can be reliably estimated in a regime determined by the sample diffusivity, the local flow velocity, and the Gaussian beam waist. We experimentally show that a smaller beam waist results in an improvement of the velocity sensitivity at cost of the precision and accuracy of the estimation of the diffusion coefficient. Further, we show that the decay of the OCT autocorrelation due to flow depends only on the Gaussian beam waist irrespective of the sample position with respect to the focus position.
△ Less
Submitted 16 November, 2014;
originally announced November 2014.
-
Magic wavelengths for the $2 \ ^3S \to 2 \ ^1S$ transition in helium
Authors:
Remy Notermans,
Robert Rengelink,
Ton van Leeuwen,
Wim Vassen
Abstract:
We have calculated ac polarizabilities of the $2 \ ^3S$ and $2 \ ^1S$ states of both $^4$He and $^3$He in the range 318 nm to 2.5 $μ$m and determined the magic wavelengths at which these polarizabilities are equal for either isotope. The calculations, only based on available ab initio tables of level energies and Einstein A coefficients, do not require advanced theoretical techniques. The polariza…
▽ More
We have calculated ac polarizabilities of the $2 \ ^3S$ and $2 \ ^1S$ states of both $^4$He and $^3$He in the range 318 nm to 2.5 $μ$m and determined the magic wavelengths at which these polarizabilities are equal for either isotope. The calculations, only based on available ab initio tables of level energies and Einstein A coefficients, do not require advanced theoretical techniques. The polarizability contribution of the continuum is calculated using a simple extrapolation beyond the ionization limit, yet the results agree to better than 1% with such advanced techniques. Several promising magic wavelengths are identified around 320 nm with sufficient accuracy to design an appropriate laser system. The extension of the calculations to $^3$He is complicated due to the additional hyperfine structure, but we show that the magic wavelength candidates around 320 nm are predominantly shifted by the isotope shift.
△ Less
Submitted 13 November, 2014; v1 submitted 13 October, 2014;
originally announced October 2014.
-
The 'nanobig rods' class of gold nanorods: optimized dimensions for improved in vivo therapeutic and imaging efficacy
Authors:
Constantin Ungureanu,
Gerben A. Koning,
Ton G. van Leeuwen,
Srirang Manohar
Abstract:
Currently, gold nanorods can be synthesized in a wide range of sizes. However, for intended biological applications gold nanorods with approximate dimensions 50 nm x 15 nm are used. We investigate by computer simulation the effect of particle dimensions on the optical and thermal properties in the context of the specific applications of photoacoustic imaging. In addition we discuss the influence o…
▽ More
Currently, gold nanorods can be synthesized in a wide range of sizes. However, for intended biological applications gold nanorods with approximate dimensions 50 nm x 15 nm are used. We investigate by computer simulation the effect of particle dimensions on the optical and thermal properties in the context of the specific applications of photoacoustic imaging. In addition we discuss the influence of particle size in overcoming the following biophysical barriers when administrated in vivo: extravasation, avoidance of uptake by organs of the reticuloendothelial system, penetration through the interstitium, binding capability and uptake by the target cells. Although more complex biological influences can be introduced in future analysis, the present work illustrates that larger gold nanorods, designated by us as "nanobig rods", may perform relatively better at meeting the requirements for successful in vivo applications compared to their smaller counterparts which are conventionally used.
△ Less
Submitted 3 April, 2013; v1 submitted 29 March, 2013;
originally announced March 2013.
-
An optimized ultrasound detector for photoacoustic breast tomography
Authors:
Wenfeng Xia,
Daniele Piras,
Johan Van Hespen,
Spiridon Van Veldhoven,
Christian Prins,
Ton Van Leeuwen,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the expected photoacoustic frequency bandwidth (a few MHz to tens of kHz) is inversely propo…
▽ More
Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the expected photoacoustic frequency bandwidth (a few MHz to tens of kHz) is inversely proportional to the dimensions of light absorbing structures (0.5 to 10+ mm), proper choices of materials and their geometries, and proper considerations in design have to be made for optimal photoacoustic detectors. In this study, we design and evaluate a specialized ultrasound detector for photoacoustic mammography. Based on the required detector sensitivity and its frequency response, a selection of active material and matching layers and their geometries is made leading to a functional detector models. By iteration between simulation of detector performances, fabrication and experimental characterization of functional models an optimized implementation is made and evaluated. The experimental results of the designed first and second functional detectors matched with the simulations. In subsequent bare piezoelectric samples the effect of lateral resonances was addressed and their influence minimized by sub-dicing the samples. Consequently, using simulations, the final optimized detector could be designed, with a center frequency of 1 MHz and a -6 dB bandwidth of ~80%. The minimum detectable pressure was measured to be 0.5 Pa, which will facilitate deeper imaging compared to the currrent systems. The detector should be capable of detecting vascularized tumors with resolution of 1-2 mm. Further improvements by proper electrical grounding and shielding and implementation of this design into an arrayed detector will pave the way for clinical applications of photoacoustic mammography.
△ Less
Submitted 13 February, 2013; v1 submitted 11 December, 2012;
originally announced December 2012.
-
Speed-of-sound compensated photoacoustic tomography for accurate imaging
Authors:
Jithin Jose,
Rene G. H. Willemink,
Wiendelt Steenbergen,
Cornelis H. Slump,
Ton G. van Leeuwen,
Srirang Manohar
Abstract:
In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed under this assumption. We present experimental and image reconstruction methods with which 2-D SOS distributions can be accurately acquired and reconstructed, and…
▽ More
In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed under this assumption. We present experimental and image reconstruction methods with which 2-D SOS distributions can be accurately acquired and reconstructed, and with which the SOS map can be used subsequently to reconstruct highly accurate PA tomograms. We begin with a 2-D iterative reconstruction approach in an ultrasound transmission tomography (UTT) setting, which uses ray refracted paths instead of straight ray paths to recover accurate SOS images of the subject. Subsequently, we use the SOS distribution in a new 2-D iterative approach, where refraction of rays originating from PA sources are accounted for in accurately retrieving the distribution of these sources. Both the SOS reconstruction and SOS-compensated PA reconstruction methods utilize the Eikonal equation to model acoustic wavefront propagation, which is solved using a high accuracy fast marching method (HAFMM). We validate the new reconstruction algorithms using numerical phantoms. For experiments we use the PER-PACT method which can be used to simultaneously acquire SOS and PA data from subjects. We test the reconstruction algorithms using experimental data acquired with the PER-PACT setup from challenging physical phantoms. The results show that it is important to take SOS inhomogeneities into account. The iterative reconstruction algorithms, that model acoustic refractive effects, yield artifact-free highly accurate images. Our approach of using the hybrid measurement method and the new reconstruction algorithms, is successful in substantially improving the quality of PA images with a minimization of blurring and artefacts.
△ Less
Submitted 30 October, 2012; v1 submitted 6 June, 2012;
originally announced June 2012.
-
On the correlation between bibliometric indicators and peer review: Reply to Opthof and Leydesdorff
Authors:
Ludo Waltman,
Nees Jan van Eck,
Thed N. van Leeuwen,
Martijn S. Visser,
Anthony F. J. van Raan
Abstract:
Opthof and Leydesdorff [arXiv:1102.2569] reanalyze data reported by Van Raan [arXiv:physics/0511206] and conclude that there is no significant correlation between on the one hand average citation scores measured using the CPP/FCSm indicator and on the other hand the quality judgment of peers. We point out that Opthof and Leydesdorff draw their conclusions based on a very limited amount of data. We…
▽ More
Opthof and Leydesdorff [arXiv:1102.2569] reanalyze data reported by Van Raan [arXiv:physics/0511206] and conclude that there is no significant correlation between on the one hand average citation scores measured using the CPP/FCSm indicator and on the other hand the quality judgment of peers. We point out that Opthof and Leydesdorff draw their conclusions based on a very limited amount of data. We also criticize the statistical methodology used by Opthof and Leydesdorff. Using a larger amount of data and a more appropriate statistical methodology, we do find a significant correlation between the CPP/FCSm indicator and peer judgment.
△ Less
Submitted 26 May, 2011;
originally announced May 2011.
-
Severe Language Effect in University Rankings: Particularly Germany and France are wronged in citation-based rankings
Authors:
Anthony F. J. van Raan,
Thed N. van Leeuwen,
Martijn S. Visser
Abstract:
We applied a set of standard bibliometric indicators to monitor the scientific state-of-arte of 500 universities worldwide and constructed a ranking on the basis of these indicators (Leiden Ranking 2010). We find a dramatic and hitherto largely underestimated language effect in the bibliometric, citation-based measurement of research performance when comparing the ranking based on all Web of Scien…
▽ More
We applied a set of standard bibliometric indicators to monitor the scientific state-of-arte of 500 universities worldwide and constructed a ranking on the basis of these indicators (Leiden Ranking 2010). We find a dramatic and hitherto largely underestimated language effect in the bibliometric, citation-based measurement of research performance when comparing the ranking based on all Web of Science (WoS) covered publications and on only English WoS covered publications, particularly for Germany and France.
△ Less
Submitted 23 December, 2010;
originally announced December 2010.
-
Towards a new crown indicator: An empirical analysis
Authors:
Ludo Waltman,
Nees Jan van Eck,
Thed N. van Leeuwen,
Martijn S. Visser,
Anthony F. J. van Raan
Abstract:
We present an empirical comparison between two normalization mechanisms for citation-based indicators of research performance. These mechanisms aim to normalize citation counts for the field and the year in which a publication was published. One mechanism is applied in the current so-called crown indicator of our institute. The other mechanism is applied in the new crown indicator that our institu…
▽ More
We present an empirical comparison between two normalization mechanisms for citation-based indicators of research performance. These mechanisms aim to normalize citation counts for the field and the year in which a publication was published. One mechanism is applied in the current so-called crown indicator of our institute. The other mechanism is applied in the new crown indicator that our institute is planning to adopt. We find that at high aggregation levels, such as at the level of large research institutions or at the level of countries, the differences between the two mechanisms are very small. At lower aggregation levels, such as at the level of research groups or at the level of journals, the differences between the two mechanisms are somewhat larger. We pay special attention to the way in which recent publications are handled. These publications typically have very low citation counts and should therefore be handled with special care.
△ Less
Submitted 7 September, 2010; v1 submitted 9 April, 2010;
originally announced April 2010.
-
Towards a new crown indicator: Some theoretical considerations
Authors:
Ludo Waltman,
Nees Jan van Eck,
Thed N. van Leeuwen,
Martijn S. Visser,
Anthony F. J. van Raan
Abstract:
The crown indicator is a well-known bibliometric indicator of research performance developed by our institute. The indicator aims to normalize citation counts for differences among fields. We critically examine the theoretical basis of the normalization mechanism applied in the crown indicator. We also make a comparison with an alternative normalization mechanism. The alternative mechanism turns o…
▽ More
The crown indicator is a well-known bibliometric indicator of research performance developed by our institute. The indicator aims to normalize citation counts for differences among fields. We critically examine the theoretical basis of the normalization mechanism applied in the crown indicator. We also make a comparison with an alternative normalization mechanism. The alternative mechanism turns out to have more satisfactory properties than the mechanism applied in the crown indicator. In particular, the alternative mechanism has a so-called consistency property. The mechanism applied in the crown indicator lacks this important property. As a consequence of our findings, we are currently moving towards a new crown indicator, which relies on the alternative normalization mechanism.
△ Less
Submitted 16 August, 2010; v1 submitted 10 March, 2010;
originally announced March 2010.
-
Rivals for the crown: Reply to Opthof and Leydesdorff
Authors:
Anthony F. J. van Raan,
Thed N. van Leeuwen,
Martijn S. Visser,
Nees Jan van Eck,
Ludo Waltman
Abstract:
We reply to the criticism of Opthof and Leydesdorff [arXiv:1002.2769] on the way in which our institute applies journal and field normalizations to citation counts. We point out why we believe most of the criticism is unjustified, but we also indicate where we think Opthof and Leydesdorff raise a valid point.
We reply to the criticism of Opthof and Leydesdorff [arXiv:1002.2769] on the way in which our institute applies journal and field normalizations to citation counts. We point out why we believe most of the criticism is unjustified, but we also indicate where we think Opthof and Leydesdorff raise a valid point.
△ Less
Submitted 10 March, 2010;
originally announced March 2010.
-
Is scientific literature subject to a sell-by-date? A general methodology to analyze the durability of scientific documents
Authors:
Rodrigo Costas,
Thed N. van Leeuwen,
Anthony F. J. van Raan
Abstract:
The study of the citation histories and ageing of documents are topics that have been addressed from several perspectives, especially in the analysis of documents with delayed recognition or sleeping beauties. However, there is no general methodology that can be extensively applied for different time periods and/or research fields. In this paper a new methodology for the general analysis of the…
▽ More
The study of the citation histories and ageing of documents are topics that have been addressed from several perspectives, especially in the analysis of documents with delayed recognition or sleeping beauties. However, there is no general methodology that can be extensively applied for different time periods and/or research fields. In this paper a new methodology for the general analysis of the ageing and durability of scientific papers is presented. This methodology classifies documents into three general types: Delayed documents, which receive the main part of their citations later than normal documents; Flash in the pans, which receive citations immediately after their publication but they are not cited in the long term; and Normal documents, documents with a typical distribution of citations over time. These three types of durability have been analyzed considering the whole population of documents in the Web of Science with at least 5 external citations (i.e. not considering self-citations). Several patterns related to the three types of durability have been found and the potential for further research of the developed methodology is discussed.
△ Less
Submitted 9 July, 2009;
originally announced July 2009.
-
Scaling rules in the science system: influence of field-specific citation characteristics on the impact of individual researchers
Authors:
Rodrigo Costas,
Maria Bordons,
Thed N. van Leeuwen,
Anthony F. J. van Raan
Abstract:
The representation of science as a citation-density landscape and the study of scaling rules with the field-specific citation-density as a main topological property was previously analysed at the level of research groups. Here the focus is on the individual researcher. In this new analysis, the size-dependence of several main bibliometric indicators for a large set of individual researchers is e…
▽ More
The representation of science as a citation-density landscape and the study of scaling rules with the field-specific citation-density as a main topological property was previously analysed at the level of research groups. Here the focus is on the individual researcher. In this new analysis, the size-dependence of several main bibliometric indicators for a large set of individual researchers is explored. Similar results as those previously observed for research groups are here described for individual researchers, reinforcing the idea of prevalent scaling rules in the representation of science as a citation-density landscape. Differences among thematic areas with different citation densities are discussed.
△ Less
Submitted 7 March, 2008;
originally announced March 2008.