Skip to main content

Showing 1–28 of 28 results for author: Vlachos, P

  1. arXiv:2407.04583  [pdf, other

    physics.data-an physics.flu-dyn

    Unbalanced optimal transport for stochastic particle tracking

    Authors: Kairui Hao, Atharva Hans, Pavlos Vlachos, Ilias Bilionis

    Abstract: Non-invasive flow measurement techniques, such as particle tracking velocimetry, resolve 3D velocity fields by pairing tracer particle positions in successive time steps. These trajectories are crucial for evaluating physical quantities like vorticity, shear stress, pressure, and coherent structures. Traditional approaches deterministically reconstruct particle positions and extract particle track… ▽ More

    Submitted 5 July, 2024; originally announced July 2024.

    MSC Class: 68T01 ACM Class: J.2.7

  2. arXiv:2101.07358  [pdf

    physics.flu-dyn physics.app-ph physics.plasm-ph

    Shock generated vorticity in spark discharges

    Authors: Bhavini Singh, Lalit K. Rajendran, Pavlos P. Vlachos, Sally P. M. Bane

    Abstract: Spark discharges induce a complex flow field consisting of a shock wave at early times (~ 1 $μ$ s), a pair of vortex rings, and a hot gas kernel. The vortex rings entrain ambient gas into the hot gas kernel and control its cooling and expansion. In this work, we investigate the shock wave's contribution in producing the vortex ring vorticity. We analyze high-speed (700 kHz) schlieren images of the… ▽ More

    Submitted 19 March, 2021; v1 submitted 18 January, 2021; originally announced January 2021.

    Comments: Submitted to the Journal of Physics D

  3. arXiv:2012.11682  [pdf

    physics.flu-dyn physics.data-an physics.ins-det

    Meta-Uncertainty for Particle Image Velocimetry

    Authors: Lalit K. Rajendran, Sayantan Bhattacharya, Sally P. M. Bane, Pavlos P. Vlachos

    Abstract: Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measur… ▽ More

    Submitted 21 December, 2020; originally announced December 2020.

    Comments: submitted to Measurement Science and Technology

  4. arXiv:2010.08446  [pdf

    physics.flu-dyn physics.plasm-ph

    Filamentary Surface Plasma Discharge Flow Length and Time Scales

    Authors: Lalit K. Rajendran, Bhavini Singh, Pavlos P. Vlachos, Sally P. M. Bane

    Abstract: Nanosecond Surface Dielectric Barrier Discharge (ns-SDBDs) are a class of plasma actuators that utilize a high-voltage pulse of nanosecond duration between two surface-mounted electrodes to create an electrical breakdown of air, along with rapid heating. These actuators usually produce multiple filaments when operated at high pulse frequencies, and the rapid heating leads to the formation of shock… ▽ More

    Submitted 16 October, 2020; originally announced October 2020.

    Comments: Submitted to Journal of Physics D: Applied Physics

  5. arXiv:2007.11065  [pdf

    physics.flu-dyn physics.app-ph physics.plasm-ph

    Vortex rings drive entrainment and cooling in flow induced by a spark discharge

    Authors: Bhavini Singh, Lalit K. Rajendran, Jiacheng Zhang, Pavlos P. Vlachos, Sally P. M. Bane

    Abstract: Spark plasma discharges induce vortex rings and a hot gas kernel. We develop a model to describe the late stage of the spark induced flow and the role of the vortex rings in the entrainment of cold ambient gas and the cooling of the hot gas kernel. The model is tested in a plasma-induced flow, using density and velocity measurements obtained from simultaneous stereoscopic particle image velocimetr… ▽ More

    Submitted 21 July, 2020; originally announced July 2020.

    Comments: Submitted to Physical Review Fluids

    Journal ref: Phys. Rev. Fluids 5, 114501 (2020)

  6. arXiv:2004.01217  [pdf

    physics.flu-dyn physics.ins-det

    Weighted Least Squares (WLS) Density Integration for Background Oriented Schlieren (BOS)

    Authors: Lalit Rajendran, Jiacheng Zhang, Sally Bane, Pavlos Vlachos

    Abstract: We propose an improved density integration methodology for Background Oriented Schlieren (BOS) measurements that overcomes the noise sensitivity of the commonly used Poisson solver. The method employs a weighted least-squares (WLS) optimization of the 2D integration of the density gradient field by solving an over-determined system of equations. Weights are assigned to the grid points based on den… ▽ More

    Submitted 2 April, 2020; originally announced April 2020.

    Comments: submitted to Experiments in Fluids

  7. arXiv:2003.11672  [pdf

    physics.med-ph

    Direct estimation of global longitudinal strain from echocardiograms using a logarithm-scaled Fourier magnitude correlation

    Authors: Brett A. Meyers, Melissa C. Brindise, Vivek Jani, Shelby Kutty, Pavlos P. Vlachos

    Abstract: We present a new method for measuring global longitudinal strain and global longitudinal strain rate from 2D echocardiograms using a logarithmic-transform correlation (LTC) method. In contrast to traditional echocardiography strain analysis, our approach does not require cardiac chamber segmentation and regularization. The algorithm was benchmarked against two conventional strain analysis methods… ▽ More

    Submitted 24 May, 2021; v1 submitted 25 March, 2020; originally announced March 2020.

    Comments: 22 pages, 3 figures

  8. To Seal or Not To Seal

    Authors: Javad Eshraghi, Sunghwan Jung, Pavlos P. Vlachos

    Abstract: When an object impacts the free surface of a liquid, it ejects a splash curtain upwards and creates an air cavity below the free surface. As the object descends into the liquid, the air cavity eventually closes under the action of hydrostatic pressure (deep seal). In contrast, the surface curtain may splash outwards or dome over and close, creating a surface seal. In this paper we experimentally i… ▽ More

    Submitted 12 December, 2019; originally announced December 2019.

    Journal ref: Phys. Rev. Fluids 5, 104001 (2020)

  9. arXiv:1912.00130  [pdf

    physics.flu-dyn physics.comp-ph

    Uncertainty-based pressure field reconstruction from PIV/PTV flow measurements with generalized least-squares

    Authors: Jiacheng Zhang, Sayantan Bhattacharya, Pavlos P. Vlachos

    Abstract: A novel uncertainty-based pressure reconstruction method is proposed to evaluate the instantaneous pressure fields from velocity fields measured using particle image velocimetry (PIV) or particle tracking velocimetry (PTV). First, the pressure gradient fields are calculated from velocity fields, while the local and instantaneous pressure gradient uncertainty is estimated from the velocity uncertai… ▽ More

    Submitted 29 November, 2019; originally announced December 2019.

  10. arXiv:1911.12495  [pdf

    physics.flu-dyn eess.IV

    Volumetric Particle Tracking Velocimetry (PTV) Uncertainty Quantification

    Authors: Sayantan Bhattacharya, Pavlos P. Vlachos

    Abstract: We introduce the first comprehensive approach to determine the uncertainty in volumetric Particle Tracking Velocimetry (PTV) measurements. Volumetric PTV is a state-of-the-art non-invasive flow measurement technique, which measures the velocity field by recording successive snapshots of the tracer particle motion using a multi-camera set-up. The measurement chain involves reconstructing the three-… ▽ More

    Submitted 27 November, 2019; originally announced November 2019.

  11. arXiv:1910.11942  [pdf

    physics.med-ph q-bio.QM

    A Wavelet Approach for the Estimation of Left Ventricular Early Filling Wave Propagation Velocity from Color-M-Mode Echocardiograms

    Authors: Sreyashi Chakraborty, Hiroyuki Iwano, Michael E. Hall, Pavlos P. Vlachos

    Abstract: Objective: This work evaluates a new approach for calculating the left-ventricular (LV) early filling propagation velocity (VP) from color M-Mode (CMM) echocardiograms using wavelet analysis. Unlike current approaches, the method requires no assumptions, user inputs, or heuristic conventions. Background: Current methods for measuring VP using CMM echocardiography do not account for the spatiotempo… ▽ More

    Submitted 25 October, 2019; originally announced October 2019.

  12. arXiv:1910.09379  [pdf

    physics.flu-dyn physics.ao-ph physics.data-an physics.ins-det

    Uncertainty amplification due to density/refractive-index gradients in volumetric PTV and BOS experiments

    Authors: Lalit K. Rajendran, Sally P. M. Bane, Pavlos P. Vlachos

    Abstract: We theoretically analyze the effect of density/refractive-index gradients on the measurement precision of Volumetric Particle Tracking Velocimetry (V-PTV) and Background Oriented Schlieren (BOS) experiments by deriving the Cramer-Rao lower bound (CRLB) for the 2D centroid estimation process. A model is derived for the diffraction limited image of a particle or dot viewed through a medium containin… ▽ More

    Submitted 21 October, 2019; originally announced October 2019.

    Comments: Submitted to Experiments in Fluids

  13. arXiv:1909.09126  [pdf

    physics.flu-dyn physics.app-ph physics.plasm-ph

    Two Regime Cooling in Flow Induced by a Spark Discharge

    Authors: Bhavini Singh, Lalit Rajendran, Pavlos P Vlachos, Sally Bane

    Abstract: The cooling process associated with the flow induced by a spark plasma discharge generated between a pair of electrodes is measured using stereoscopic particle image velocimetry (S-PIV) and background oriented schlieren (BOS). Density measurements show that the hot gas kernel initially cools fast by convective cooling, followed by a slower cooling process. The cooling rates during the fast regime… ▽ More

    Submitted 19 September, 2019; originally announced September 2019.

    Journal ref: Phys. Rev. Fluids 5, 014501 (2020)

  14. arXiv:1909.06643  [pdf

    physics.flu-dyn physics.data-an physics.ins-det

    Uncertainty Quantification in density estimation from Background Oriented Schlieren (BOS) measurements

    Authors: Lalit K. Rajendran, Jiacheng Zhang, Sayantan Bhattacharya, Sally P . M. Bane, Pavlos P. Vlachos

    Abstract: We present an uncertainty quantification methodology for density estimation from Background Oriented Schlieren (BOS) measurements, in order to provide local, instantaneous, a-posteriori uncertainty bounds on each density measurement in the field of view. Displacement uncertainty quantification algorithms from cross-correlation based Particle Image Velocimetry (PIV) are used to estimate the uncerta… ▽ More

    Submitted 14 September, 2019; originally announced September 2019.

    Comments: Submitted to Measurement Science and Technology

  15. arXiv:1904.13201  [pdf

    physics.flu-dyn physics.comp-ph

    4D-Flow MRI Pressure Estimation Using Velocity Measurement-Error based Weighted Least-Squares

    Authors: Jiacheng Zhang, Melissa C. Brindise, Sean Rothenberger, Susanne Schnell, Michael Markl, David Saloner, Vitaliy L. Rayz, Pavlos P. Vlachos

    Abstract: This work introduces a 4D-flow magnetic resonance imaging (MRI) pressure reconstruction method which employs weighted least-squares (WLS) for pressure integration. Pressure gradients are calculated from the velocity fields, and velocity errors are estimated from the velocity divergence for incompressible flow. Pressure gradient errors are estimated by propagating the velocity errors through Navier… ▽ More

    Submitted 30 April, 2019; originally announced April 2019.

  16. Flow field evolution and entrainment in a free surface plunging jet

    Authors: Syed Harris Hassan, Tianqi Guo, Pavlos P. Vlachos

    Abstract: We investigate ambient fluid entrainment and near-field flow characteristics of a free surface plunging jet for five Reynolds numbers ranging from 3000 to 10000 using time-resolved stereo particle image velocimetry (SPIV). We present time-averaged velocities, RMS velocity fluctuations, mean entrainment and unsteady flow features and compare them with previous studies on free jets. We find that plu… ▽ More

    Submitted 5 March, 2019; originally announced March 2019.

    Journal ref: Phys. Rev. Fluids 4, 104603 (2019)

  17. arXiv:1903.01303  [pdf

    physics.flu-dyn

    Patient-Specific Cerebral Aneurysm Hemodynamics: Comparison of in vitro Volumetric Particle Velocimetry, Computational Fluid Dynamics (CFD), and in vivo 4D Flow MRI

    Authors: Melissa C. Brindise, Sean Rothenberger, Benjamin Dickerhoff, Susanne Schnell, Michael Markl, David Saloner, Vitaliy L. Rayz, Pavlos P. Vlachos

    Abstract: Typical approaches to patient-specific hemodynamic studies of cerebral aneurysms use image based computational fluid dynamics (CFD) and seek to statistically correlate parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) to risk of growth and rupture. However, such studies have reported contradictory results, emphasizing the need for in-depth comparisons of volumetric exper… ▽ More

    Submitted 4 March, 2019; originally announced March 2019.

  18. Dot-Tracking Methodology for Background Oriented Schlieren (BOS)

    Authors: Lalit K. Rajendran, Sally P. M. Bane, Pavlos P. Vlachos

    Abstract: We propose a dot-tracking methodology for processing Background Oriented Schlieren (BOS) images. The method significantly improves the accuracy, precision and spatial resolution compared to conventional cross-correlation algorithms. Our methodology utilizes the prior information about the dot pattern such as the location, size and number of dots to provide near 100% yield even for high dot densiti… ▽ More

    Submitted 27 December, 2018; originally announced December 2018.

    Comments: 14 pages, 7 figures. Submitted to Experiments in Fluids

  19. arXiv:1812.10580  [pdf

    physics.med-ph physics.flu-dyn

    Color-Doppler Echocardiography Flow Field Velocity Reconstruction Using a Streamfunction -Vorticity Formulation

    Authors: Brett A Meyers, Craig J Goergen, Patrick Segers, Pavlos P Vlachos

    Abstract: We introduce a new method, (Doppler Velocity Reconstruction or DoVeR), for reconstructing two-component velocity fields from color Doppler scans. DoVeR employs the streamfunction-vorticity equation, which satisfies mass conservation while accurately approximating the flow rate of rotation. We validated DoVeR using artificial color Doppler images generated from computational fluid dynamics models o… ▽ More

    Submitted 21 October, 2020; v1 submitted 26 December, 2018; originally announced December 2018.

    Comments: 32 Pages, 6 Figures

  20. arXiv:1812.05902  [pdf

    eess.IV physics.flu-dyn physics.optics

    PIV/BOS Synthetic Image Generation in Variable Density Environments for Error Analysis and Experiment Design

    Authors: Lalit K. Rajendran, Sally P. M. Bane, Pavlos P. Vlachos

    Abstract: We present an image generation methodology based on ray tracing that can be used to render realistic images of Particle Image Velocimetry (PIV) and Background Oriented Schlieren (BOS) experiments in the presence of density/refractive index gradients. This methodology enables the simulation of aero-thermodynamics experiments for experiment design, error, and uncertainty analysis. Images are generat… ▽ More

    Submitted 12 December, 2018; originally announced December 2018.

    Comments: 11 pages, 4 figures. Submitted to Measurement Science and Technology

  21. arXiv:1804.10854  [pdf

    physics.flu-dyn physics.data-an

    Particle Image Velocimetry (PIV) Uncertainty Quantification Using Moment of Correlation (MC) Plane

    Authors: Sayantan Bhattacharya, John J. Charonko, Pavlos P. Vlachos

    Abstract: We present a new uncertainty estimation method for Particle Image Velocimetry (PIV), that uses the correlation plane as a model for the probability density function (PDF) of displacements and calculates the second order moment of the correlation (MC). The cross-correlation between particle image patterns is the summation of all particle matches convolved with the apparent particle image diameter.… ▽ More

    Submitted 28 April, 2018; originally announced April 2018.

  22. arXiv:1603.03460  [pdf

    physics.flu-dyn

    Confocal laser scanning microscopy image correlation for nanoparticle flow velocimetry

    Authors: Brian Jun, Matthew Giarra, Haisheng Yang, Russell Main, Pavlos Vlachos

    Abstract: We present a new particle image correlation technique for resolving nanoparticle flow velocity using confocal laser scanning microscopy (CLSM). The two primary issues that complicate nanoparticle scanning laser image correlation (SLIC) based velocimetry are (1) the use of diffusion dominated nanoparticles as flow tracers, which introduce a random decorrelating error into the velocity estimate, and… ▽ More

    Submitted 10 March, 2016; originally announced March 2016.

    Comments: 30 pages, 13 figures, 2 tables, submitted to Measurement Science and Technology - Special Issue Article (PIV 2015)

  23. arXiv:1603.03343  [pdf

    physics.flu-dyn

    Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: an in vitro study

    Authors: Melissa C. Brindise, Claudio Chiastra, Francesco Burzotta, Francesco Migliavacca, Pavlos P. Vlachos

    Abstract: Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions w… ▽ More

    Submitted 10 March, 2016; originally announced March 2016.

    Comments: 33 pages, 8 figures, 3 tables

  24. arXiv:1405.3125  [pdf

    physics.flu-dyn

    Time-resolved particle image velocimetry measurements with wall shear stress and uncertainty quantification for the FDA benchmark nozzle model

    Authors: Jaime S. Raben, Prasanna Hariharan, Ronald Robinson, Richard Malinauskas, Pavlos P. Vlachos

    Abstract: We present validation of benchmark experimental data for computational fluid dynamics (CFD) analyses of medical devices using advanced Particle Image Velocimetry (PIV) processing and post-processing techniques. This work is an extension of a previous FDA-sponsored multi-laboratory study, which used a medical device mimicking geometry referred to as the FDA benchmark nozzle model. Time-resolved PIV… ▽ More

    Submitted 13 May, 2014; originally announced May 2014.

  25. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    Authors: Zhenyu Xue, John J. Charonko, Pavlos P. Vlachos

    Abstract: In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the c… ▽ More

    Submitted 12 May, 2014; originally announced May 2014.

  26. arXiv:1309.3180  [pdf, other

    physics.flu-dyn

    Demonstration of Experimental Three Dimensional Finite Time Lyapunov Exponents with Inertial Particles

    Authors: Samuel G. Raben, Shane D. Ross, Pavlos P. Vlachos

    Abstract: This work provides an experimental method for simultaneously measuring finite time Lyapunov exponent fields for multiple particle groups, including non-flow tracers, in three-dimensional multiphase flows. From sequences of particle images, e.g., from experimental fluid imaging techniques, we can directly compute the flow map and coherent structures, with out performing the computationally costly n… ▽ More

    Submitted 4 October, 2013; v1 submitted 12 September, 2013; originally announced September 2013.

  27. arXiv:1309.2969  [pdf, other

    physics.flu-dyn

    Lift and wakes of flying snakes

    Authors: Anush Krishnan, John J. Socha, Pavlos P. Vlachos, L. A. Barba

    Abstract: Flying snakes use a unique method of aerial locomotion: they jump from tree branches, flatten their bodies and undulate through the air to produce a glide. The shape of their body cross-section during the glide plays an important role in generating lift. This paper presents a computational investigation of the aerodynamics of the cross-sectional shape. Two-dimensional simulations of incompressible… ▽ More

    Submitted 7 February, 2014; v1 submitted 11 September, 2013; originally announced September 2013.

    Comments: 19 pages, 16 figures

    Journal ref: Phys. Fluids, Vol. 26, 031901 (2014)

  28. arXiv:1210.3650  [pdf, other

    physics.flu-dyn

    Straight-line and turning locomotion of Paramecia

    Authors: Saikat Jana, Matthew Giarra, Pavlos Vlachos, Sunghwan Jung

    Abstract: In this fluid dynamics video we investigate the flow field around straight-line swimming and right and left turning Paramecia using micro- particle image velocimetry (μPIV). A Paramecium controls its ciliary beating to produce different fluid velocities on either side of its body. This phenomenon is visualized by applying μPIV to images in which Paramecia swim in a dilute suspension of 1 μm polyst… ▽ More

    Submitted 12 October, 2012; originally announced October 2012.

    Comments: 1 page; 2 videos