LEEx-B: Low Energy Experimental Bench Development at IPHC-CNRS Strasbourg
Authors:
E. Bouquerel,
T. Adama,
C. Maazouzi,
E. Traykov,
P. Graehling,
C. Mathieu
Abstract:
As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform and providing beams up to 25 keV. A beam profiler and an Allison-type emittance-meter allow the qualification of the setup and also the characterization of the…
▽ More
As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform and providing beams up to 25 keV. A beam profiler and an Allison-type emittance-meter allow the qualification of the setup and also the characterization of the beam. During the commissioning process, the electronics, and the control system were upgraded in order to push the limits towards low beam currents measured by the emittance-meter.
△ Less
Submitted 2 July, 2024;
originally announced July 2024.
-
Challenges in low losses and large acceptance ion beam transport
Authors:
F Osswald,
E Traykov,
T Durand,
M Heine,
J Michaud,
J C Thomas
Abstract:
A prototype of ion beam transport module has been developed at the Institut Pluridisciplinaire Hubert Curien (IPHC) and used as a test bed to investigate key issues related to the efficient transport of ion beams. This includes the reduction of the beam losses, the increase of the acceptance, and the definition of the instrumentation necessary to evaluate the performances. An experiment was perfor…
▽ More
A prototype of ion beam transport module has been developed at the Institut Pluridisciplinaire Hubert Curien (IPHC) and used as a test bed to investigate key issues related to the efficient transport of ion beams. This includes the reduction of the beam losses, the increase of the acceptance, and the definition of the instrumentation necessary to evaluate the performances. An experiment was performed on a full-scale beam line and following a standard beam analysis, steering, and focusing procedure. After a review of the developments carried out for some demanding facilities and for the design of the quadrupoles implemented in the transport module, the paper highlights the challenge of measuring the preservation of transverse phase-space distributions with large acceptance conditions, i.e. with the highest ratio of beam filling to quadrupole aperture. Then, the tolerance to the errors and mitigation of the risks are discussed, in particular by considering the electric stability of the transport module, beam trips, behavior of the tail and the halo, and misalignment errors.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
High-resolution laser system for the S3-Low Energy Branch
Authors:
Jekabs Romans,
Anjali Ajayakumar,
Martial Authier,
Frederic Boumard,
Lucia Caceres,
Jean-Francois Cam,
Arno Claessens,
Samuel Damoy,
Pierre Delahaye,
Philippe Desrues,
Wenling Dong,
Antoine Drouart,
Patricia Duchesne,
Rafael Ferrer,
Xavier Flechard,
Serge Franchoo,
Patrice Gangnant,
Sarina Geldhof,
Ruben P. de Groote,
Nathalie Lecesne,
Renan Leroy,
Julien Lory,
Franck Lutton,
Vladimir Manea,
Yvan Merrer
, et al. (17 additional authors not shown)
Abstract:
In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S$^3$-Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S$^3$. The measured isotope-shift and hyperfine structure…
▽ More
In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S$^3$-Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S$^3$. The measured isotope-shift and hyperfine structure data are presented for stable isotopes of these elements. The erbium isotopes were studied using the $4f^{12}6s^2$ $^3H_6 \rightarrow 4f^{12}(^3 H)6s6p$ $J = 5$ atomic transition (415 nm) and the tin isotopes were studied by the $5s^25p^2 (^3P_0) \rightarrow 5s^25p6s (^3P_1)$ atomic transition (286.4 nm), and are used as a benchmark of the laser setup. Additionally, the tin isotopes were studied by the $5s^25p6s (^3P_1) \rightarrow 5s^25p6p (^3P_2)$ atomic transition (811.6 nm), for which new isotope-shift data was obtained and the corresponding field-shift $F_{812}$ and mass-shift $M_{812}$ factors are presented.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
Green beam lines, a challenging concept
Authors:
F. Osswald,
E. Traykov,
T. Durand,
M. Heine,
J. Michaud,
J. C. Thomas
Abstract:
Due to increasing environmental and economic constraints, optimization of ion beam transport and equipment design becomes essential. The future should be equipped with planet-friendly facilities, that is, solutions that reduce environmental impact and improve economic competitiveness. The tendency to increase the intensity of the current and the power of the beams obliges us and brings us to new c…
▽ More
Due to increasing environmental and economic constraints, optimization of ion beam transport and equipment design becomes essential. The future should be equipped with planet-friendly facilities, that is, solutions that reduce environmental impact and improve economic competitiveness. The tendency to increase the intensity of the current and the power of the beams obliges us and brings us to new challenges. Installations tend to have larger dimensions with increased areas, volumes, weights and costs. A new ion beam transport prototype was developed and used as a test bed to identify key issues to reduce beam losses and preserve transverse phase-space distributions with large acceptance conditions.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Transverse emittance measurement in 2D and 4D performed on a Low Energy Beam Transport line: benchmarking and data analysis
Authors:
F Osswald,
T Durand,
M Heine,
J Michaud,
F Poirier,
J C Thomas,
E Traykov
Abstract:
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the two emittance meters. We compare the results from three series of measurements and present the advantages and drawbacks of the two systems. Coupling between phas…
▽ More
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the two emittance meters. We compare the results from three series of measurements and present the advantages and drawbacks of the two systems. Coupling between phase-space planes, correlations and mitigation of deleterious effects are discussed. The influence of background noise and aberrations of trace-space figures on emittance measurements and RMS calculations is highlighted, especially for low density beams and halos. A new data analysis method using noise reduction, filtering, and reconstruction of the emittance figure is described. Finally, some basic concepts of phase-space theory and application to beam transport are recalled.
△ Less
Submitted 9 November, 2022;
originally announced November 2022.
-
Design and Commissioning of the first two CYRCé Extension Beamlines
Authors:
E. Bouquerel,
E. Traykov,
C. Maazouzi,
M. Rousseau,
M. Pellicioli,
J. Andrea,
T. Adam,
P. Graehling,
C. Mathieu,
G. Heitz,
M. Krauth,
D. Oster,
T. Foehrenbacher,
C. Ruescas,
J. Schuler,
U. Goerlach,
C. Haas
Abstract:
CYRCé is a TR24 cyclotron installed at the Institut Pluridisciplinaire Hubert Curien (IPHC) of Strasbourg operating at energies of 16-25 MeV and at intensities up to 400 $μ$A. The accelerator is used to produce and provide radioelements for PET and for SPECT. In 2015, IPHC started to develop a platform with the aim of performing radiobiological experiments. The PRECy platform foresees to contain t…
▽ More
CYRCé is a TR24 cyclotron installed at the Institut Pluridisciplinaire Hubert Curien (IPHC) of Strasbourg operating at energies of 16-25 MeV and at intensities up to 400 $μ$A. The accelerator is used to produce and provide radioelements for PET and for SPECT. In 2015, IPHC started to develop a platform with the aim of performing radiobiological experiments. The PRECy platform foresees to contain three-to-five experimental stations linked to beamlines expanded from the second exit port of the cyclotron. This extension allows devoting one of the beamlines for detector studies within the framework of the CMS project. The design, the development and the commissioning of the first two beamlines are discussed in this paper.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
New exotic beams from the SPIRAL 1 upgrade
Authors:
P. Delahaye,
M. Dubois,
L. Maunoury,
J. Angot,
O. Bajeat,
B. Blank,
J. C. Cam,
P. Chauveau,
R. Frigot,
B. Jacquot,
P. Jardin,
P. Lecomte,
S. Hormigos,
O. Kamalou,
V. Kuchi,
B. Osmond,
B. M. Retailleau,
A. Savalle,
T. Stora,
V. Toivanen,
J. C. Thomas,
E. Traykov,
P. Ujic,
R. Vondrasek
Abstract:
Since 2001, the SPIRAL 1 facility has been one of the pioneering facilities in ISOL techniques for reaccelerating radioactive ion beams: the fragmentation of the heavy ion beams of GANIL on graphite targets and subsequent ionization in the Nanogan ECR ion source has permitted to deliver beams of gaseous elements (He, N, O, F, Ne, Ar, Kr) to numerous experiments. Thanks to the CIME cyclotron, energ…
▽ More
Since 2001, the SPIRAL 1 facility has been one of the pioneering facilities in ISOL techniques for reaccelerating radioactive ion beams: the fragmentation of the heavy ion beams of GANIL on graphite targets and subsequent ionization in the Nanogan ECR ion source has permitted to deliver beams of gaseous elements (He, N, O, F, Ne, Ar, Kr) to numerous experiments. Thanks to the CIME cyclotron, energies up to 20 AMeV could be obtained. In 2014, the facility was stopped to undertake a major upgrade, with the aim to extend the production capabilities of SPIRAL 1 to a number of new elements. This upgrade, which is presently under commissioning, consists in the integration of an ECR booster in the SPIRAL 1 beam line to charge breed the beam of different 1+ sources. A FEBIAD source (the so-called VADIS from ISOLDE) was chosen to be the future workhorse for producing many metallic ion beams. The charge breeder is an upgraded version of the Phoenix booster which was previously tested in ISOLDE. The performances of the aforementioned ingredients of the upgrade (targets, 1+ source and charge breeder) have been and are still being optimized in the frame of different European projects (EMILIE, ENSAR and ENSAR2). The upgraded SPIRAL 1 facility will provide soon its first new beams for physics and further beam development are undertaken to prepare for the next AGATA campaign. The results obtained during the on-line commissioning period permit to evaluate intensities for new beams from the upgraded facility.
△ Less
Submitted 6 March, 2019;
originally announced March 2019.
-
Aspects of Cooling at the TRI$μ$P Facility
Authors:
L. Willmann,
G. P. Berg,
U. Dammalapati,
S. De,
P. Dendooven,
O. Dermois,
K. Jungmann,
A. Mol,
C. J. G. Onderwater,
A. Rogachevskiy,
M. Sohani,
E. Traykov,
H. W. Wilschut
Abstract:
The Tri$μ$P facility at KVI is dedicated to provide short lived radioactive isotopes at low kinetic energies to users. It comprised different cooling schemes for a variety of energy ranges, from GeV down to the neV scale. The isotopes are produced using beam of the AGOR cyclotron at KVI. They are separated from the primary beam by a magnetic separator. A crucial part of such a facility is the ab…
▽ More
The Tri$μ$P facility at KVI is dedicated to provide short lived radioactive isotopes at low kinetic energies to users. It comprised different cooling schemes for a variety of energy ranges, from GeV down to the neV scale. The isotopes are produced using beam of the AGOR cyclotron at KVI. They are separated from the primary beam by a magnetic separator. A crucial part of such a facility is the ability to stop and extract isotopes into a low energy beamline which guides them to the experiment. In particular we are investigating stopping in matter and buffer gases. After the extraction the isotopes can be stored in neutral atoms or ion traps for experiments. Our research includes precision studies of nuclear $β$-decay through $β$-$ν$ momentum correlations as well as searches for permanent electric dipole moments in heavy atomic systems like radium. Such experiments offer a large potential for discovering new physics.
△ Less
Submitted 3 February, 2006;