Two-bunch seeding of soft X-ray free electron lasers
Authors:
E. Schneidmiller,
I. Zagorodnov
Abstract:
Seeded Free Electron Lasers (FELs) demonstrate a good performance and are successfully used in different user experiments in extreme ultraviolet and soft X-ray regimes. In this paper a simple modification of the seeding scenario is proposed relying on generation of two closely spaced bunches with very different properties: a low-current seeding bunch, and a high-current bunch that amplifies cohere…
▽ More
Seeded Free Electron Lasers (FELs) demonstrate a good performance and are successfully used in different user experiments in extreme ultraviolet and soft X-ray regimes. In this paper a simple modification of the seeding scenario is proposed relying on generation of two closely spaced bunches with very different properties: a low-current seeding bunch, and a high-current bunch that amplifies coherent radiation, produced by the seeding bunch. This approach eliminates different limitations and mitigates some harmful effects in the standard scenario. In particular, one can generate very high harmonic numbers with a moderate laser power in a simple high-gain harmonic generation (HGHG) scheme. Alternatively, in case of moderate harmonic numbers, one can strongly reduce the required laser power thus simplifying design of high repetition rate seeded FELs. An influence of beam dynamics effects (like nonlinearities of the longitudinal phase space of electron beams, coherent synchrotron radiation, longitudinal space charge, geometrical wakefields, microbunching instabilities etc.) on properties of output radiation (spectrum broadening, pedestals, stability) can be to a large extent reduced in the proposed scheme. In this paper we illustrate the operation of the two-bunch seeding scheme in HGHG configuration with realistic start-to-end simulations for the soft X-ray user facility FLASH. We show that nearly Fourier-limited multi-gigawatt pulses can be generated at 4 nm using the present compact design of the undulator system. With several thousand pulses per second this can be a unique source for photon science.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Coherent High-Harmonic Generation with Laser-Plasma Beams
Authors:
S. A. Antipov,
I. Agapov,
R. Brinkmann,
Á. Ferran Pousa,
A. Martinez de la Ossa,
E. A. Schneidmiller,
M. Thévenet
Abstract:
Active energy compression scheme is presently being investigated for future laser-plasma accelerators. This method enables generating laser-plasma accelerator electron beams with a small, $\sim 10^{-5}$, relative slice energy spread. When modulated by a laser pulse, such beams can produce coherent radiation at very high, $\sim 100$-th harmonics of the modulation laser wavelength, which are hard to…
▽ More
Active energy compression scheme is presently being investigated for future laser-plasma accelerators. This method enables generating laser-plasma accelerator electron beams with a small, $\sim 10^{-5}$, relative slice energy spread. When modulated by a laser pulse, such beams can produce coherent radiation at very high, $\sim 100$-th harmonics of the modulation laser wavelength, which are hard to access by conventional techniques. The scheme has a potential of providing additional capabilities for future plasma-based facilities by generating stable, tunable, narrow-band radiation.
△ Less
Submitted 12 June, 2024; v1 submitted 6 June, 2024;
originally announced June 2024.
-
First high peak and average power single-pass THz FEL based on high brightness photoinjector
Authors:
M. Krasilnikov,
Z. Aboulbanine,
G. Adhikari,
N. Aftab,
A. Asoyan,
P. Boonpornprasert,
H. Davtyan,
G. Georgiev,
J. Good,
A. Grebinyk,
M. Gross,
A. Hoffmann,
E. Kongmon,
X. -K. Li,
A. Lueangaramwong,
D. Melkumyan,
S. Mohanty,
R. Niemczyk,
A. Oppelt,
H. Qian,
C. Richard,
F. Stephan,
G. Vashchenko,
T. Weilbach,
X. Zhang
, et al. (9 additional authors not shown)
Abstract:
Advanced experiments using THz pump and X-ray probe pulses at modern free-electron lasers (FELs) like the European X-ray FEL require a frequency-tunable, high-power, narrow-band THz source maintaining the repetition rate and pulse structure of the X-ray pulses. This paper reports the first results from a THz source, that is based on a single-pass high-gain THz FEL operating with a central waveleng…
▽ More
Advanced experiments using THz pump and X-ray probe pulses at modern free-electron lasers (FELs) like the European X-ray FEL require a frequency-tunable, high-power, narrow-band THz source maintaining the repetition rate and pulse structure of the X-ray pulses. This paper reports the first results from a THz source, that is based on a single-pass high-gain THz FEL operating with a central wavelength of 100 micrometers. The THz FEL prototype is currently in operation at the Photo Injector Test facility at DESY in Zeuthen (PITZ) and uses the same type of electron source as the European XFEL photo injector. A self-amplified spontaneous emission (SASE) FEL was envisioned as the main mechanism for generating the THz pulses. Although the THz FEL at PITZ is supposed to use the same mechanism as at X-ray facilities, it cannot be considered as a simple scaling of the radiation wavelength because there is a large difference in the number of electrons per radiation wavelength, which is five orders of magnitude higher for the THz case. The bunching factor arising from the electron beam current profile contributes strongly to the initial spontaneous emission starting the FEL process. Proof-of-principle experiments were done at PITZ using an LCLS-I undulator to generate the first high-power, high-repetition-rate single-pass THz FEL radiation. Electron bunches with a beam energy of ~17 MeV and a bunch charge of up to several nC are used to generate THz pulses with a pulse energy of several tens of microjoules. For example, for an electron beam with a charge of ~2.4 nC, more than 100 microjoules were generated at a central wavelength of 100 micrometers. The narrowband spectrum was also demonstrated by spectral measurements. These proof-of-principle experiments pave the way for a tunable, high-repetition-rate THz source providing pulses with energies in the millijoule range.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Opportunities for Gas-Phase Science at Short-Wavelength Free-Electron Lasers with Undulator-Based Polarization Control
Authors:
Markus Ilchen,
Enrico Allaria,
Primož Rebernik Ribič,
Heinz-Dieter Nuhn,
Alberto Lutman,
Evgeny Schneidmiller,
Markus Tischer,
Mikail Yurkov,
Marco Calvi,
Eduard Prat,
Sven Reiche,
Thomas Schmidt,
Gianluca Aldo Geloni,
Suren Karabekyan,
Jiawei Yan,
Svitozar Serkez,
Zhangfeng Gao,
Bangjie Deng,
Chao Feng,
Haixiao Deng,
Wolfram Helml,
Lars Funke,
Mats Larsson,
Vitali,
Zhaunerchyk
, et al. (22 additional authors not shown)
Abstract:
Free-electron lasers (FELs) are the world's most brilliant light sources with rapidly evolving technological capabilities in terms of ultrabright and ultrashort pulses over a large range of accessible photon energies. Their revolutionary and innovative developments have opened new fields of science regarding nonlinear light-matter interaction, the investigation of ultrafast processes from specific…
▽ More
Free-electron lasers (FELs) are the world's most brilliant light sources with rapidly evolving technological capabilities in terms of ultrabright and ultrashort pulses over a large range of accessible photon energies. Their revolutionary and innovative developments have opened new fields of science regarding nonlinear light-matter interaction, the investigation of ultrafast processes from specific observer sites, and approaches to imaging matter with atomic resolution. A core aspect of FEL science is the study of isolated and prototypical systems in the gas phase with the possibility of addressing well-defined electronic transitions or particular atomic sites in molecules. Notably for polarization-controlled short-wavelength FELs, the gas phase offers new avenues for investigations of nonlinear and ultrafast phenomena in spin orientated systems, for decoding the function of the chiral building blocks of life as well as steering reactions and particle emission dynamics in otherwise inaccessible ways. This roadmap comprises descriptions of technological capabilities of facilities worldwide, innovative diagnostics and instrumentation, as well as recent scientific highlights, novel methodology and mathematical modeling. The experimental and theoretical landscape of using polarization controllable FELs for dichroic light-matter interaction in the gas phase will be discussed and comprehensively outlined to stimulate and strengthen global collaborative efforts of all disciplines.
△ Less
Submitted 19 November, 2023;
originally announced November 2023.
-
Two-color operation of a soft x-ray FEL with alternation of undulator tunes
Authors:
E. A. Schneidmiller,
I. J. Bermudez Macias,
M. Beye,
M. Braune,
M. -K. Czwalinna,
S. Duesterer,
B. Faatz,
R. Ivanov,
F. Jastrow,
M. Kuhlmann,
J. Roensch-Schulenburg,
S. Schreiber,
A. Sorokin,
K. Tiedtke,
M. V. Yurkov,
J. Zemella
Abstract:
FLASH is the first soft X-ray FEL user facility, routinely providing brilliant photon beams for users since 2005. The second undulator branch of this facility, FLASH2, is gap-tunable which allows to test and use advanced lasing concepts. In particular, we developed a two-color operation mode based on the alternatingly tuned undulator segments (every other segment is tuned to the second wavelength)…
▽ More
FLASH is the first soft X-ray FEL user facility, routinely providing brilliant photon beams for users since 2005. The second undulator branch of this facility, FLASH2, is gap-tunable which allows to test and use advanced lasing concepts. In particular, we developed a two-color operation mode based on the alternatingly tuned undulator segments (every other segment is tuned to the second wavelength). This scheme is advantageous in comparison with a subsequent generation of two colors in two consecutive sections of the undulator line. First, source positions of the two FEL beams are close to each other which makes it easier to focus them on a sample. Second, the amplification is more efficient in this configuration since the segments with respectively "wrong" wavelength still act as bunchers. We studied operation of this scheme in the regime of small and large separation of tunes (up to a factor of two). We developed new methods for online intensity measurements of the two colors simultaneously that require a combination of two detectors. We also demonstrated our capabilities to measure spectral and temporal properties of two pulses with different wavelengths.
△ Less
Submitted 14 November, 2022;
originally announced November 2022.
-
First measurement of energy diffusion in an electron beam due to quantum fluctuations in the undulator radiation
Authors:
Sergey Tomin,
Evgeny Schneidmiller,
Winfried Decking
Abstract:
We present measurements of slice energy spread growth due to quantum fluctuations of the undulator radiation at the European X-Ray Free-Electron Laser. The method uses a recently installed diagnostic wakefield structure, which enables measurements of the longitudinal phase space after the hard X-ray undulator. The effect of quantum diffusion in the undulator is measured for the first time, and the…
▽ More
We present measurements of slice energy spread growth due to quantum fluctuations of the undulator radiation at the European X-Ray Free-Electron Laser. The method uses a recently installed diagnostic wakefield structure, which enables measurements of the longitudinal phase space after the hard X-ray undulator. The effect of quantum diffusion in the undulator is measured for the first time, and the results are in good agreement with theoretical predictions.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
Application of a modified chirp-taper scheme for generation of attosecond pulses in XUV and soft X-ray FELs
Authors:
E. A. Schneidmiller
Abstract:
Typically, in Self-Amplified Spontaneous Emission Free Electron Laser (SASE FEL) based short-pulse schemes, pulse duration is limited by FEL coherence time. For hard X-ray FELs, coherence time is in a few hundred attosecond range while for XUV and soft X-ray FELs it is in the femtosecond regime. In this paper the modification of so-called chirp-taper scheme is developed that allows to overcome the…
▽ More
Typically, in Self-Amplified Spontaneous Emission Free Electron Laser (SASE FEL) based short-pulse schemes, pulse duration is limited by FEL coherence time. For hard X-ray FELs, coherence time is in a few hundred attosecond range while for XUV and soft X-ray FELs it is in the femtosecond regime. In this paper the modification of so-called chirp-taper scheme is developed that allows to overcome the coherence time barrier. Numerical simulations for XUV and soft X-ray FEL user facility FLASH demonstrate that one can generate a few hundred attosecond long pulses in the wavelength range 2 - 10 nm with peak power reaching hundreds of megawatts. With several thousand pulses per second this can be a unique source for attosecond science.
△ Less
Submitted 22 October, 2021;
originally announced October 2021.
-
Observation of harmonic lasing in the Angstrom regime at European XFEL
Authors:
E. A. Schneidmiller,
F. Brinker,
W. Decking,
L. Froehlich,
M. Guetg,
D. Noelle,
M. Scholz,
M. V. Yurkov,
I. Zagorodnov,
G. Geloni,
N. Gerasimova,
J. Gruenert,
J. Laksman,
J. Liu,
S. Karabekyan,
N. Kujala,
Th. Maltezopoulos,
I. Petrov,
L. Samoylova,
S. Serkez,
H. Sinn,
F. Wolff-Fabris
Abstract:
Harmonic lasing provides an opportunity to extend the photon energy range of existing and planned X-ray FEL user facilities. Contrary to nonlinear harmonic generation, harmonic lasing can generate a much more intense, stable, and narrow-band FEL beam. Another interesting application is Harmonic Lasing Self-Seeding (HLSS) that allows to improve the longitudinal coherence and spectral power of a Sel…
▽ More
Harmonic lasing provides an opportunity to extend the photon energy range of existing and planned X-ray FEL user facilities. Contrary to nonlinear harmonic generation, harmonic lasing can generate a much more intense, stable, and narrow-band FEL beam. Another interesting application is Harmonic Lasing Self-Seeding (HLSS) that allows to improve the longitudinal coherence and spectral power of a Self-Amplified Spontaneous Emission (SASE) FEL. This concept was tested at FLASH in the range of 4.5 - 15 nm and at PAL XFEL at 1 nm. In this paper we present recent results from the European XFEL where we successfully demonstrated harmonic lasing at 5.9 Angstrom and 2.8 Angstrom. In the latter case we obtained both 3rd and 5th harmonic lasing and, for the first time, operated a harmonic lasing cascade (5th-3rd-1st harmonics of the undulator). These results pave the way for reaching very high photon energies, up to 100 keV.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.
-
First operation of a harmonic lasing self-seeded free electron laser
Authors:
E. A. Schneidmiller,
B. Faatz,
M. Kuhlmann,
J. Roensch-Schulenburg,
S. Schreiber,
M. Tischer,
M. V. Yurkov
Abstract:
Harmonic lasing is a perspective mode of operation of X-ray FEL user facilities that allows to provide brilliant beams of higher energy photons for user experiments. Another useful application of harmonic lasing is so called Harmonic Lasing Self-Seeded Free Electron Laser (HLSS FEL) that allows to improve spectral brightness of these facilities. In the past, harmonic lasing has been demonstrated i…
▽ More
Harmonic lasing is a perspective mode of operation of X-ray FEL user facilities that allows to provide brilliant beams of higher energy photons for user experiments. Another useful application of harmonic lasing is so called Harmonic Lasing Self-Seeded Free Electron Laser (HLSS FEL) that allows to improve spectral brightness of these facilities. In the past, harmonic lasing has been demonstrated in the FEL oscillators in infrared and visible wavelength ranges, but not in high-gain FELs and not at short wavelengths. In this paper we report on the first evidence of the harmonic lasing and the first operation of the HLSS FEL at the soft X-ray FEL user facility FLASH in the wavelength range between 4.5 nm and 15 nm. Spectral brightness was improved in comparison with Self-Amplified Spontaneous emission (SASE) FEL by a factor of six in the exponential gain regime. A better performance of HLSS FEL with respect to SASE FEL in the post-saturation regime with a tapered undulator was observed as well. The first demonstration of harmonic lasing in a high-gain FEL and at short wavelengths paves the way for a variety of applications of this new operation mode in X-ray FELs.
△ Less
Submitted 14 December, 2016; v1 submitted 12 December, 2016;
originally announced December 2016.
-
SIMEX: Simulation of Experiments at Advanced Light Sources
Authors:
C Fortmann-Grote,
A A Andreev,
R Briggs,
M Bussmann,
A Buzmakov,
M Garten,
A Grund,
A Hübl,
S Hauff,
A Joy,
Z Jurek,
N D Loh,
T Rüter,
L Samoylova,
R Santra,
E A Schneidmiller,
A Sharma,
M Wing,
S Yakubov,
C H Yoon,
M V Yurkov,
B Ziaja,
A P Mancuso
Abstract:
Realistic simulations of experiments at large scale photon facilities, such as optical laser laboratories, synchrotrons, and free electron lasers, are of vital importance for the successful preparation, execution, and analysis of these experiments investigating ever more complex physical systems, e.g. biomolecules, complex materials, and ultra-short lived states of highly excited matter. Tradition…
▽ More
Realistic simulations of experiments at large scale photon facilities, such as optical laser laboratories, synchrotrons, and free electron lasers, are of vital importance for the successful preparation, execution, and analysis of these experiments investigating ever more complex physical systems, e.g. biomolecules, complex materials, and ultra-short lived states of highly excited matter. Traditional photon science modelling takes into account only isolated aspects of an experiment, such as the beam propagation, the photon-matter interaction, or the scattering process, making idealized assumptions about the remaining parts, e.g.\ the source spectrum, temporal structure and coherence properties of the photon beam, or the detector response. In SIMEX, we have implemented a platform for complete start-to-end simulations, following the radiation from the source, through the beam transport optics to the sample or target under investigation, its interaction with and scattering from the sample, and its registration in a photon detector, including a realistic model of the detector response to the radiation. Data analysis tools can be hooked up to the modelling pipeline easily. This allows researchers and facility operators to simulate their experiments and instruments in real life scenarios, identify promising and unattainable regions of the parameter space and ultimately make better use of valuable beamtime.
This work is licensed under the Creative Commons Attribution 3.0 Unported License: http://creativecommons.org/licenses/by/3.0/.
△ Less
Submitted 17 November, 2016; v1 submitted 19 October, 2016;
originally announced October 2016.
-
Coherence properties of the radiation from FLASH
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
FLASH is the first free electron laser user facility operating in the vacuum ultraviolet and soft x-ray wavelength range. Many user experiments require knowledge of the spatial and temporal coherence properties of the radiation. In this paper we present an analysis of the coherence properties of the radiation for the fundamental and for the higher odd frequency harmonics. We show that temporal and…
▽ More
FLASH is the first free electron laser user facility operating in the vacuum ultraviolet and soft x-ray wavelength range. Many user experiments require knowledge of the spatial and temporal coherence properties of the radiation. In this paper we present an analysis of the coherence properties of the radiation for the fundamental and for the higher odd frequency harmonics. We show that temporal and spatial coherence reach maximum close to the FEL saturation but may degrade significantly in the post-saturation regime. We also find that the pointing stability of short FEL pulses is limited due to the fact that non-azimuthal FEL eigenmodes are not sufficiently suppressed. We discuss possible ways for improving the degree of transverse coherence and the pointing stability.
△ Less
Submitted 16 February, 2015;
originally announced February 2015.
-
Statistical properties of the radiation from SASE FEL operating in a post-saturation regime with and without undulator tapering
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We describe statistical and coherence properties of the radiation from x-ray free electron lasers (XFEL) operating in the post-saturation regime. We consider practical case of the SASE3 FEL at the European XFEL. We perform comparison of the main characteristics of the X-ray FEL operating in the post-saturation regime with and without undulator tapering: efficiency, coherence time and degree of tra…
▽ More
We describe statistical and coherence properties of the radiation from x-ray free electron lasers (XFEL) operating in the post-saturation regime. We consider practical case of the SASE3 FEL at the European XFEL. We perform comparison of the main characteristics of the X-ray FEL operating in the post-saturation regime with and without undulator tapering: efficiency, coherence time and degree of transverse coherence.
△ Less
Submitted 5 January, 2015;
originally announced January 2015.
-
Optimization of a high efficiency FEL amplifier
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
The problem of an efficiency increase of an FEL amplifier is now of great practical importance. Technique of undulator tapering in the post-saturation regime is used at the existing x-ray FELs LCLS and SACLA, and is planned for use at the European XFEL, Swiss FEL, and PAL XFEL. There are also discussions on the future of high peak and average power FELs for scientific and industrial applications.…
▽ More
The problem of an efficiency increase of an FEL amplifier is now of great practical importance. Technique of undulator tapering in the post-saturation regime is used at the existing x-ray FELs LCLS and SACLA, and is planned for use at the European XFEL, Swiss FEL, and PAL XFEL. There are also discussions on the future of high peak and average power FELs for scientific and industrial applications. In this paper we perform detailed analysis of the tapering strategies for high power seeded FEL amplifiers. Application of similarity techniques allows us to derive universal law of the undulator tapering.
△ Less
Submitted 22 October, 2014;
originally announced October 2014.
-
Prospects for CW and LP operation of the European XFEL in hard X-ray regime
Authors:
R. Brinkmann,
E. A. Schneidmiller,
J. Sekutowicz,
M. V. Yurkov
Abstract:
The European XFEL will operate nominally at 17.5 GeV in SP (short pulse) mode with 0.65 ms long bunch train and 10 Hz repetition rate. A possible upgrade of the linac to CW (continuous wave) or LP (long pulse) modes with a corresponding reduction of electron beam energy is under discussion since many years. Recent successes in the dedicated R&D program allow to forecast a technical feasibility of…
▽ More
The European XFEL will operate nominally at 17.5 GeV in SP (short pulse) mode with 0.65 ms long bunch train and 10 Hz repetition rate. A possible upgrade of the linac to CW (continuous wave) or LP (long pulse) modes with a corresponding reduction of electron beam energy is under discussion since many years. Recent successes in the dedicated R&D program allow to forecast a technical feasibility of such an upgrade in the foreseeable future. One of the challenges is to provide sub-Angstrom FEL operation in CW and LP modes. In this paper we perform a preliminary analysis of a possible operation of the European XFEL in the hard X-ray regime in CW and LP modes with the energies of 7 GeV and 10 GeV, respectively. We consider lasing in the baseline XFEL undulator as well as in a new undulator with a reduced period. We show that, with reasonable requirements on electron beam quality, lasing on the fundamental will be possible in sub-Angstrom regime. As an option for generation of brilliant photon beams at short wavelengths we also consider harmonic lasing that has recently attracted a significant attention.
△ Less
Submitted 3 March, 2014;
originally announced March 2014.
-
Obtaining high degree of circular polarization at X-ray FELs via a reverse undulator taper
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Baseline design of a typical X-ray FEL undulator assumes a planar configuration which results in a linear polarization of the FEL radiation. However, many experiments at X-ray FEL user facilities would profit from using a circularly polarized radiation. As a cheap upgrade one can consider an installation of a short helical (or cross-planar) afterburner, but then one should have an efficient method…
▽ More
Baseline design of a typical X-ray FEL undulator assumes a planar configuration which results in a linear polarization of the FEL radiation. However, many experiments at X-ray FEL user facilities would profit from using a circularly polarized radiation. As a cheap upgrade one can consider an installation of a short helical (or cross-planar) afterburner, but then one should have an efficient method to suppress powerful linearly polarized background from the main undulator. In this paper we propose a new method for such a suppression: an application of the reverse taper in the main undulator. We discover that in a certain range of the taper strength, the density modulation (bunching) at saturation is practically the same as in the case of non-tapered undulator while the power of linearly polarized radiation is suppressed by orders of magnitude. Then strongly modulated electron beam radiates at full power in the afterburner. Considering SASE3 undulator of the European XFEL as a practical example, we demonstrate that soft X-ray radiation pulses with peak power in excess of 100 GW and an ultimately high degree of circular polarization can be produced. The proposed method is rather universal, i.e. it can be used at SASE FELs and seeded (self-seeded) FELs, with any wavelength of interest, in a wide range of electron beam parameters, and with any repetition rate. It can be used at different X-ray FEL facilities, in particular at LCLS after installation of the helical afterburner in the near future.
△ Less
Submitted 15 August, 2013;
originally announced August 2013.
-
A possible upgrade of FLASH for harmonic lasing down to 1.3 nm
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We propose the 3rd harmonic lasing in a new FLASH undulator as a way to produce intense, narrow-band, and stable SASE radiation down to 1.3 nm with the present accelerator energy of 1.25 GeV. To provide optimal conditions for harmonic lasing, we suggest to suppress the fundamental with the help of a special set of phase shifters. We rely on the standard technology of gap-tunable planar hybrid undu…
▽ More
We propose the 3rd harmonic lasing in a new FLASH undulator as a way to produce intense, narrow-band, and stable SASE radiation down to 1.3 nm with the present accelerator energy of 1.25 GeV. To provide optimal conditions for harmonic lasing, we suggest to suppress the fundamental with the help of a special set of phase shifters. We rely on the standard technology of gap-tunable planar hybrid undulators, and choose the period of 2.3 cm and the minimum gap of 0.9 cm; total length of the undulator system is 34.5 m. With the help of numerical simulations we demonstrate that the 3rd harmonic lasing at 1.3 nm provides peak power at a gigawatt level and the narrow intrinsic bandwidth, 0.1% (FWHM). Pulse duration can be controlled in the range of a few tens of femtoseconds, and the peak brilliance reaches the value of 10^31 photons/(s mrad^2 mm^2 0.1%BW). With the given undulator design, a standard option of lasing at the fundamental wavelength to saturation is possible through the entire water window and at longer wavelengths. In this paper we briefly consider additional options such as polarization control, bandwidth reduction, self-seeding, X-ray pulse compression, and two-color operation. We also discuss possible technical issues and backup solutions.
△ Less
Submitted 17 October, 2012;
originally announced October 2012.
-
Harmonic lasing in X-ray FELs
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Harmonic lasing in a free electron laser with a planar undulator (under the condition that the fundamental frequency is suppressed) might be a cheap and efficient way of extension of wavelength ranges of existing and planned X-ray FEL facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam which is easier to handle due…
▽ More
Harmonic lasing in a free electron laser with a planar undulator (under the condition that the fundamental frequency is suppressed) might be a cheap and efficient way of extension of wavelength ranges of existing and planned X-ray FEL facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam which is easier to handle due to the suppressed fundamental frequency. In this paper we perform a parametrization of the solution of the eigenvalue equation for lasing at odd harmonics, and present an explicit expression for FEL gain length, taking into account all essential effects. We propose and discuss methods for suppression of the fundamental harmonic. We also suggest a combined use of harmonic lasing and lasing at the retuned fundamental wavelength in order to reduce bandwidth and to increase brilliance of X-ray beam at saturation. Considering 3rd harmonic lasing as a practical example, we come to the conclusion that it is much more robust than usually thought, and can be widely used in the existing or planned X-ray FEL facilities. In particular, LCLS after a minor modification can lase to saturation at the 3rd harmonic up to the photon energy of 25-30 keV providing multi-gigawatt power level and narrow bandwidth. As for the European XFEL, harmonic lasing would allow to extend operating range (ultimately up to 100 keV), to reduce FEL bandwidth and to increase brilliance, to enable two-color operation for pump-probe experiments, and to provide more flexible operation at different electron energies. Finally, in this paper we discover that in a part of the parameter space, corresponding to the operating range of soft X-ray beamlines of X-ray FEL facilities (like SASE3 beamline of the European XFEL), harmonics can grow faster than the fundamental wavelength.
△ Less
Submitted 11 May, 2012;
originally announced May 2012.
-
Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser
Authors:
C. Behrens,
N. Gerasimova,
Ch. Gerth,
B. Schmidt,
E. A. Schneidmiller,
S. Serkez,
S. Wesch,
M. V. Yurkov
Abstract:
The successful operation of X-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse dur…
▽ More
The successful operation of X-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft X-ray pulse durations and electron bunch lengths at FLASH. The soft X-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft X-ray pulses with durations below 50 fs (FWHM) after the implementation of the new uniform electron bunch compression scheme used at FLASH.
△ Less
Submitted 6 March, 2012; v1 submitted 20 January, 2012;
originally announced January 2012.
-
Potential of the FLASH FEL technology for the construction of a kW-scale light source for the next generation lithography
Authors:
E. A. Schneidmiller,
V. F. Vogel,
H. Weise,
M. V. Yurkov
Abstract:
The driving engine of the Free Electron Laser in Hamburg (FLASH) is an L-band superconducting accelerator. It is designed to operate in burst mode with 800 microsecond pulse duration at a repetition rate of 10 Hz. The maximum accelerated beam current during the macropulse is 9 mA. Our analysis shows that the FLASH technology has great potential since it is possible to construct a FLASH like free e…
▽ More
The driving engine of the Free Electron Laser in Hamburg (FLASH) is an L-band superconducting accelerator. It is designed to operate in burst mode with 800 microsecond pulse duration at a repetition rate of 10 Hz. The maximum accelerated beam current during the macropulse is 9 mA. Our analysis shows that the FLASH technology has great potential since it is possible to construct a FLASH like free electron laser operating at the wavelength of 13.5 and 6.8 nanometer with an average power up to 2.6 kW. Such a source meets the physical requirements for the light source for the next generation lithography.
△ Less
Submitted 30 August, 2011;
originally announced August 2011.
-
Generation of attosecond soft x-ray pulses in a longitudinal space charge amplifier
Authors:
M. Dohlus,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
A longitudinal space charge amplifier (LSCA), operating in soft x-ray regime, was recently proposed. Such an amplifier consists of a few amplification cascades (focusing channel and chicane) and a short radiator undulator in the end. Broadband nature of LSCA supports generation of few-cycle pulses as well as wavelength compression. In this paper we consider an application of these properties of LS…
▽ More
A longitudinal space charge amplifier (LSCA), operating in soft x-ray regime, was recently proposed. Such an amplifier consists of a few amplification cascades (focusing channel and chicane) and a short radiator undulator in the end. Broadband nature of LSCA supports generation of few-cycle pulses as well as wavelength compression. In this paper we consider an application of these properties of LSCA for generation of attosecond x-ray pulses. It is shown that a compact and cheap addition to the soft x-ray free electron laser facility FLASH would allow to generate 60 attosecond (FWHM) long x-ray pulses with the peak power at 100 MW level and a contrast above 98%.
△ Less
Submitted 9 March, 2011;
originally announced March 2011.
-
Using the longitudinal space charge instability for generation of VUV and X-ray radiation
Authors:
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Longitudinal space charge (LSC) driven microbunching instability in electron beam formation systems of X-ray FELs is a recently discovered effect hampering beam instrumentation and FEL operation. The instability was observed in different facilities in infrared and visible wavelength ranges. In this paper we propose to use such an instability for generation of VUV and X-ray radiation. A typical lon…
▽ More
Longitudinal space charge (LSC) driven microbunching instability in electron beam formation systems of X-ray FELs is a recently discovered effect hampering beam instrumentation and FEL operation. The instability was observed in different facilities in infrared and visible wavelength ranges. In this paper we propose to use such an instability for generation of VUV and X-ray radiation. A typical longitudinal space charge amplifier (LSCA) consists of few amplification cascades (drift space plus chicane) with a short undulator behind the last cascade. If the amplifier starts up from the shot noise, the amplified density modulation has a wide band, on the order of unity. The bandwidth of the radiation within the central cone is given by inverse number of undulator periods. A wavelength compression could be an attractive option for LSCA since the process is broadband, and a high compression stability is not required. LSCA can be used as a cheap addition to the existing or planned short-wavelength FELs. In particular, it can produce the second color for a pump-probe experiment. It is also possible to generate attosecond pulses in the VUV and X-ray regimes. Some user experiments can profit from a relatively large bandwidth of the radiation, and this is easy to obtain in LSCA scheme. Finally, since the amplification mechanism is broadband and robust, LSCA can be an interesting alternative to self-amplified spontaneous emission free electron laser (SASE FEL) in the case of using laser-plasma accelerators as drivers of light sources.
△ Less
Submitted 30 March, 2010;
originally announced March 2010.
-
Possible operation of the European XFEL with ultra-low emittance beams
Authors:
R. Brinkmann,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Recent successful lasing of the Linac Coherent Light Source (LCLS) in the hard x-ray regime and the experimental demonstration of a possibility to produce low-charge bunches with ultra-small normalized emittance have lead to the discussions on optimistic scenarios of operation of the European XFEL. In this paper we consider new options that make use of low-emittance beams, a relatively high beam…
▽ More
Recent successful lasing of the Linac Coherent Light Source (LCLS) in the hard x-ray regime and the experimental demonstration of a possibility to produce low-charge bunches with ultra-small normalized emittance have lead to the discussions on optimistic scenarios of operation of the European XFEL. In this paper we consider new options that make use of low-emittance beams, a relatively high beam energy, tunable-gap undulators, and a multi-bunch capability of this facility. We study the possibility of operation of a spontaneous radiator (combining two of them, U1 and U2, in one beamline) in the SASE mode in the designed photon energy range 20-90 keV and show that it becomes possible with ultra-low emittance electron beams similar to those generated in LCLS. As an additional attractive option we consider the generation of powerful soft x-ray and VUV radiation by the same electron bunch for pump-probe experiments, making use of recently invented compact afterburner scheme. We also propose a betatron switcher as a simple, cheap, and robust solution for multi-color operation of SASE1 and SASE2 undulators, allowing to generate 2 to 5 x-ray beams of different independent colors from each of these undulators for simultaneous multi-user operation. We describe a scheme for pump-probe experiments, based on a production of two different colors by two closely spaced electron bunches (produced in photoinjector) with the help of a very fast betatron switcher. Finally, we discuss how without significant modifications of the layout the European XFEL can become a unique facility that continuously covers with powerful, coherent radiation a part of the electromagnetic spectrum from far infrared to gamma-rays.
△ Less
Submitted 21 January, 2010;
originally announced January 2010.
-
Statistical and coherence properties of radiation from X-ray free electron lasers
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We describe statistical and coherence properties of the radiation from x-ray free electron lasers (XFEL). It is shown that the X-ray FEL radiation before saturation is described with gaussian statistics. Particularly important is the case of the optimized X-ray FEL, studied in detail. Applying similarity techniques to the results of numerical simulations allowed us to find universal scaling rela…
▽ More
We describe statistical and coherence properties of the radiation from x-ray free electron lasers (XFEL). It is shown that the X-ray FEL radiation before saturation is described with gaussian statistics. Particularly important is the case of the optimized X-ray FEL, studied in detail. Applying similarity techniques to the results of numerical simulations allowed us to find universal scaling relations for the main characteristics of an X-ray FEL operating in the saturation regime: efficiency, coherence time and degree of transverse coherence. We find that with an appropriate normalization of these quantities, they are functions of only the ratio of the geometrical emittance of the electron beam to the radiation wavelength. Statistical and coherence properties of the higher harmonics of the radiation are highlighted as well.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Method for the determination of the three-dimensional structure of ultrashort relativistic electron bunches
Authors:
Gianluca Geloni,
Petr Ilinski,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
We describe a novel technique to characterize ultrashort electron bunches in X-ray Free-Electron Lasers. Namely, we propose to use coherent Optical Transition Radiation to measure three-dimensional (3D) electron density distributions. Our method relies on the combination of two known diagnostics setups, an Optical Replica Synthesizer (ORS) and an Optical Transition Radiation (OTR) imager. Electr…
▽ More
We describe a novel technique to characterize ultrashort electron bunches in X-ray Free-Electron Lasers. Namely, we propose to use coherent Optical Transition Radiation to measure three-dimensional (3D) electron density distributions. Our method relies on the combination of two known diagnostics setups, an Optical Replica Synthesizer (ORS) and an Optical Transition Radiation (OTR) imager. Electron bunches are modulated at optical wavelengths in the ORS setup. When these electron bunches pass through a metal foil target, coherent radiation pulses of tens MW power are generated. It is thereafter possible to exploit advantages of coherent imaging techniques, such as direct imaging, diffractive imaging, Fourier holography and their combinations. The proposed method opens up the possibility of real-time, wavelength-limited, single-shot 3D imaging of an ultrashort electron bunch.
△ Less
Submitted 11 May, 2009;
originally announced May 2009.
-
Theory of edge radiation
Authors:
Gianluca Geloni,
Vitali Kocharyan,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and c…
▽ More
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and other issues becoming important at high electron energy and long radiation wavelength. Based on this work we also study the impact of Edge Radiation on XFEL setups and we discuss recent results.
△ Less
Submitted 13 August, 2008;
originally announced August 2008.
-
Transverse coherence properties of X-ray beams in third-generation synchrotron radiation sources
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
This article describes a complete theory of spatial coherence for undulator radiation sources. Current estimations of coherence properties often assume that undulator sources are quasi-homogeneous, like thermal sources, and rely on the application of the van Cittert-Zernike theorem for calculating the degree of transverse coherence. Such assumption is not adequate when treating third generation…
▽ More
This article describes a complete theory of spatial coherence for undulator radiation sources. Current estimations of coherence properties often assume that undulator sources are quasi-homogeneous, like thermal sources, and rely on the application of the van Cittert-Zernike theorem for calculating the degree of transverse coherence. Such assumption is not adequate when treating third generation light sources, because the vertical(geometrical) emittance of the electron beam is comparable or even much smaller than the radiation wavelength in a very wide spectral interval that spans over four orders of magnitude (from 0.1 Angstrom up to 10^3 Angstrom). Sometimes, the so-called Gaussian-Schell model, that is widely used in statistical optics in the description of partially-coherent sources, is applied as an alternative to the quasi-homogeneous model. However, as we will demonstrate, this model fails to properly describe coherent properties of X-ray beams from non-homogeneous undulator sources. As a result, a more rigorous analysis is required. We propose a technique, based on statistical optics and Fourier optics, to explicitly calculate the cross-spectral density of an undulator source in the most general case, at any position after the undulator. Our theory, that makes consistent use of dimensionless analysis, allows relatively easy treatment and physical understanding of many asymptotes of the parameter space, together with their region of applicability. Particular emphasis is given to the asymptotic situation when the horizontal emittance is much larger than the radiation wavelength, and the vertical emittance is arbitrary. This case is practically relevant for third generation synchrotron radiation sources.
△ Less
Submitted 29 January, 2008;
originally announced January 2008.
-
A simple method for timing an XFEL source to high-power lasers
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
We propose a technique, to be used for time-resolved pump-probe experiments, for timing an x-ray free electron laser (XFEL) to a high-power conventional laser with femtosecond accuracy. Our method takes advantage of the same electron bunch to produce both an XFEL pulse and an ultrashort optical pulse with the help of an optical radiator downstream of the x-ray undulator. Since both pulses are pr…
▽ More
We propose a technique, to be used for time-resolved pump-probe experiments, for timing an x-ray free electron laser (XFEL) to a high-power conventional laser with femtosecond accuracy. Our method takes advantage of the same electron bunch to produce both an XFEL pulse and an ultrashort optical pulse with the help of an optical radiator downstream of the x-ray undulator. Since both pulses are produced by the same electron bunch, they are perfectly synchronized. Application of cross-correlation techniques will allow to determine relative jitter between the optical pulse (and, thus, the XFEL pulse) and a pulse from an external pump-laser with femtosecond resolution. Technical realization of the proposed timing scheme uses an optical replica synthesizer (ORS) setup to be installed after the final bunch-compression stage of the XFEL. The electron bunch is modulated in the ORS setup by an external optical laser. Subsequently, it travels through the main undulator, and produces the XFEL pulse. Finally, a powerful optical pulse of coherent edge radiation is generated as the bunch passes through a long straight section and a separation magnet downstream of the main undulator. Our study shows that at a moderate (about 10%) density modulation of the electron bunch at the location of the optical radiator allows production of high power x-ray and optical pulses. Relative synchronization of these pulses is preserved by using the same mechanical support for both x-ray and optical elements transporting radiation down to the experimental area, where single-shot cross-correlation between optical pulse and pump-laser pulse is performed. We illustrate the potential of the proposed timing technique with numerical examples referring to the European XFEL facility.
△ Less
Submitted 20 December, 2007; v1 submitted 11 December, 2007;
originally announced December 2007.
-
Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron…
▽ More
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of current-enhanced SASE schemes (ESASE) recently proposed for LCLS, that fall well-within our approximations. Numerical estimations presented in this paper indicate that impedance-induced energy spread is sufficient to seriously degrade the FEL performance. Our conclusion is in contrast with results in literature, where wake calculations for the LCLS case are given in free-space, as if the presence of the undulator were negligible.
△ Less
Submitted 15 June, 2007;
originally announced June 2007.
-
Theory of Nonlinear Harmonic Generation in Free-Electron Lasers with Helical Wigglers
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
Coherent Harmonic Generation (CHG), and in particular Nonlinear Harmonic Generation (NHG), is of importance for both short wavelength Free-Electron Lasers (FELs), in relation with the achievement of shorter wavelengths with a fixed electron-beam energy, and high-average power FEL resonators, in relation with destructive effects of higher harmonics radiation on mirrors. In this paper we present a…
▽ More
Coherent Harmonic Generation (CHG), and in particular Nonlinear Harmonic Generation (NHG), is of importance for both short wavelength Free-Electron Lasers (FELs), in relation with the achievement of shorter wavelengths with a fixed electron-beam energy, and high-average power FEL resonators, in relation with destructive effects of higher harmonics radiation on mirrors. In this paper we present a treatment of NHG from helical wigglers with particular emphasis on the second harmonic. Our study is based on an exact analytical solution of Maxwell's equations, derived with the help of a Green's function method. In particular, we demonstrate that nonlinear harmonic generation (NHG) from helical wigglers vanishes on axis. Our conclusion is in open contrast with results in literature, that include a kinematical mistake in the description of the electron motion.
△ Less
Submitted 2 May, 2007;
originally announced May 2007.
-
Undulator Radiation in a Waveguide
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
We propose an analytical approach to characterize undulator radiation near resonance, when the presence of the vacuum-pipe considerably affects radiation properties. This is the case of the far-infrared undulator beamline at the Free-electron LASer (FEL) in Hamburg (FLASH), that will be capable of delivering pulses in the TeraHertz (THz) range. This undulator will allow pump-probe experiments wh…
▽ More
We propose an analytical approach to characterize undulator radiation near resonance, when the presence of the vacuum-pipe considerably affects radiation properties. This is the case of the far-infrared undulator beamline at the Free-electron LASer (FEL) in Hamburg (FLASH), that will be capable of delivering pulses in the TeraHertz (THz) range. This undulator will allow pump-probe experiments where THz pulses are naturally synchronized to the VUV pulse from the FEL, as well as the development of novel electron-beam diagnostics techniques. Since the THz radiation diffraction-size exceeds the vacuum-chamber dimensions, characterization of infrared radiation must be performed accounting for the presence of a waveguide. We developed a theory of undulator radiation in a waveguide based on paraxial and resonance approximation. We solved the field equation with a tensor Green's function technique, and extracted figure of merits describing in a simple way the influence of the vacuum-pipe on the radiation pulse as a function of the problem parameters. Our theory, that makes consistent use of dimensionless analysis, allows treatment and physical understanding of many asymptotes of the parameter space, together with their region of applicability.
△ Less
Submitted 5 March, 2007;
originally announced March 2007.
-
Longitudinal Wake Field for an Electron Beam Accelerated through a Ultra-High Field Gradient
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
Electron accelerators with higher and higher longitudinal field gradients are desirable, as they allow for the production of high energy beams by means of compact and cheap setups. The new laser-plasma acceleration technique appears to constitute the more promising breakthrough in this direction, delivering unprecedent field gradients up to TV/m. In this article we give a quantitative descriptio…
▽ More
Electron accelerators with higher and higher longitudinal field gradients are desirable, as they allow for the production of high energy beams by means of compact and cheap setups. The new laser-plasma acceleration technique appears to constitute the more promising breakthrough in this direction, delivering unprecedent field gradients up to TV/m. In this article we give a quantitative description of the impact of longitudinal wake fields on the electron beam. Our paper is based on the solution of Maxwell's equations for the longitudinal field. Our conclusions are valid when the acceleration distance is much smaller than the the overtaking length, that is the length that electrons travel as a light signal from the tail of the bunch overtakes the head of the bunch. This condition is well verified for laser-plasma devices. We calculate a closed expression for the impedance and the wake function that may be evaluated numerically. It is shown that the rate of energy loss in the bunch due to radiative interaction is equal to the energy emitted through coherent radiation in the far-zone. Furthermore, an expression is found for the asymptotic limit of a large distance of the electron beam from the accelerator compared with the overtaking length. Such expression allows us to calculate analytical solutions for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of Table-Top Free-Electron Lasers in the Vacuum Ultra-Violet (TT-VUV FEL) and X-ray range (TT-XFEL), respectively based on 100 MeV and 1 GeV laser-plasma accelerator drivers. Numerical estimations presented in this paper indicate that the effects of the time-dependent energy change induced by the longitudinal wake pose a serious threat to the operation of these devices.
△ Less
Submitted 8 December, 2006;
originally announced December 2006.
-
Coherence properties of the radiation from X-ray free electron laser
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We present a comprehensive analysis of coherence properties of the radiation from X-ray free electron laser (XFEL). We consider practically important case when XFEL is optimized for maximum gain. Such an optimization allows to reduce significantly parameter space. Application of similarity techniques to the results of numerical simulations allows to present all output characteristics of the opti…
▽ More
We present a comprehensive analysis of coherence properties of the radiation from X-ray free electron laser (XFEL). We consider practically important case when XFEL is optimized for maximum gain. Such an optimization allows to reduce significantly parameter space. Application of similarity techniques to the results of numerical simulations allows to present all output characteristics of the optimized XFEL as functions of the only parameter, ratio of the emittance to the radiation wavelength, $ \hatε = 2πε/λ$. Our studies show that optimum performance of the XFEL in terms of transverse coherence is achieved at the value of the parameter $\hatε$ of about unity. At smaller values of $\hatε$ the degree of transverse coherence is reduced due to strong influence of poor longitudinal coherence on a transverse one. At large values of the emittance the degree of transverse coherence degrades due to poor mode selection. Comparative analysis of existing XFEL projects, European XFEL, LCLS, and SCSS is presented as well.
△ Less
Submitted 7 September, 2006;
originally announced September 2006.
-
Fourier Optics treatment of Classical Relativistic Electrodynamics
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
In this paper we couple Synchrotron Radiation (SR) theory with a branch of physical optics, namely laser beam optics. We show that the theory of laser beams is successful in characterizing radiation fields associated with any SR source. Both radiation beam generated by an ultra-relativistic electron in a magnetic device and laser beam are solutions of the wave equation based on paraxial approxim…
▽ More
In this paper we couple Synchrotron Radiation (SR) theory with a branch of physical optics, namely laser beam optics. We show that the theory of laser beams is successful in characterizing radiation fields associated with any SR source. Both radiation beam generated by an ultra-relativistic electron in a magnetic device and laser beam are solutions of the wave equation based on paraxial approximation. It follows that they are similar in all aspects. In the space-frequency domain SR beams appear as laser beams whose transverse extents are large compared with the wavelength. In practical situations (e.g. undulator, bending magnet sources), radiation beams exhibit a virtual "waist" where the wavefront is often plane. Remarkably, the field distribution of a SR beam across the waist turns out to be strictly related with the inverse Fourier transform of the far-field angle distribution. Then, we take advantage of standard Fourier Optics techniques and apply the Fresnel propagation formula to characterize the SR beam. Altogether, we show that it is possible to reconstruct the near-field distribution of the SR beam outside the magnetic setup from the knowledge of the far-field pattern. The general theory of SR in the near-zone developed in this paper is illustrated for the special cases of undulator radiation, edge radiation and transition undulator radiation. Using known analytical formulas for the far-field pattern and its inverse Fourier transform we find analytical expressions for near-field distributions in terms of far-field distributions. Finally, we compare these expressions with incorrect or incomplete literature.
△ Less
Submitted 14 August, 2006;
originally announced August 2006.
-
SASE FEL with energy-chirped electron beam and its application for generation of attosecond pulses
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Influence of a linear energy chirp in the electron beam on a SASE FEL operation is studied analytically and numerically using 1-D model. Explicit expressions for Green's functions and for output power of a SASE FEL are obtained for high-gain linear regime in the limits of small and large energy chirp parameter. Saturation length and power versus energy chirp parameter are calculated numerically.…
▽ More
Influence of a linear energy chirp in the electron beam on a SASE FEL operation is studied analytically and numerically using 1-D model. Explicit expressions for Green's functions and for output power of a SASE FEL are obtained for high-gain linear regime in the limits of small and large energy chirp parameter. Saturation length and power versus energy chirp parameter are calculated numerically. It is shown that the effect of linear energy chirp on FEL gain is equivalent to the linear undulator tapering (or linear energy variation along the undulator). A consequence of this fact is a possibility to perfectly compensate FEL gain degradation, caused by the energy chirp, by means of the undulator tapering independently of the value of the energy chirp parameter. An application of this effect for generation of attosecond pulses from a hard X-ray FEL is proposed. Strong energy modulation within a short slice of an electron bunch is produced by few-cycle optical laser pulse in a short undulator, placed in front of the main undulator. Gain degradation within this slice is compensated by an appropriate undulator taper while the rest of the bunch suffers from this taper and does not lase. Three-dimensional simulations predict that short (200 attoseconds) high-power (up to 100 GW) pulses can be produced in Angstroem wavelength range with a high degree of contrast. A possibility to reduce pulse duration to sub-100 attosecond scale is discussed.
△ Less
Submitted 20 April, 2006;
originally announced April 2006.
-
Statistical Optics approach to the design of beamlines for Synchrotron Radiation
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
In this paper we analyze the image formation problem for undulator radiation through an optical system, accounting for the influence of the electron beam emittance. On the one hand, image formation with Synchrotron Radiation is governed by the laws of Statistical Optics. On the other hand, the widely used Gaussian-Shell model cannot be applied to describe the coherence properties of X-ray beams…
▽ More
In this paper we analyze the image formation problem for undulator radiation through an optical system, accounting for the influence of the electron beam emittance. On the one hand, image formation with Synchrotron Radiation is governed by the laws of Statistical Optics. On the other hand, the widely used Gaussian-Shell model cannot be applied to describe the coherence properties of X-ray beams from third generation Synchrotron Radiation sources. As a result, a more rigorous analysis of coherence properties is required. We propose a technique to explicitly calculate the cross-spectral density of an undulator source, that we subsequently propagate through an optical imaging system. At first we focus on the case of an ideal lens with a non-limiting pupil aperture. Our theory, which makes consistent use of dimensionless analysis, also allows treatment and physical understanding of many asymptotes of the parameter space, together with their applicability region. Particular emphasis is given to the asymptotic situation when the horizontal emittance is much larger than the radiation wavelength, which is relevant for third generation Synchrotron Radiation sources. First principle calculations of undulator radiation characteristics (i.e. ten-dimensional integrals) are then reduced to one-dimensional convolutions of analytical functions with universal functions specific for undulator radiation sources. We also consider the imaging problem for a non-ideal lens in presence of aberrations and a limiting pupil aperture, which increases the dimension of the convolution from one to three. In particular we give emphasis to cases when the intensity at the observation plane can be presented as a convolution of an impulse response function and the intensity from an ideal lens.
△ Less
Submitted 31 March, 2006;
originally announced March 2006.
-
Statistical properties of the radiation from VUV FEL at DESY operating at 30 nm wavelength in the femtosecond regime
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Since spring, 2005 vacuum ultraviolet free electron laser (VUV FEL) at DESY operates as user facility in the wavelength range around 30 nm. Electron beam formation system at the VUV FEL is essentially nonlinear and naturally results in a formation of a short high-current leading peak in the density distribution that produces FEL radiation. The main feature of the femtosecond mode of operation of…
▽ More
Since spring, 2005 vacuum ultraviolet free electron laser (VUV FEL) at DESY operates as user facility in the wavelength range around 30 nm. Electron beam formation system at the VUV FEL is essentially nonlinear and naturally results in a formation of a short high-current leading peak in the density distribution that produces FEL radiation. The main feature of the femtosecond mode of operation of the VUV FEL is the production of short, down to 20 fs radiation pulses with GW-level peak power. This paper is devoted to detailed studies of the short-pulse effects in the VUV FEL at DESY operating in the femtosecond regime, and to analysis of first experimental results.
△ Less
Submitted 28 November, 2005;
originally announced November 2005.
-
Properties of the odd harmonics of the radiation from SASE FEL with a planar undulator
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Recent theoretical and experimental studies have shown that Self-Amplified Spontaneous Emission Free Electron Laser (SASE FEL) with a planar undulator holds a potential for generation of relatively strong coherent radiation at the third harmonic of the fundamental frequency. Here we present detailed study of the nonlinear harmonic generation in the SASE FEL obtained with time-dependent FEL simul…
▽ More
Recent theoretical and experimental studies have shown that Self-Amplified Spontaneous Emission Free Electron Laser (SASE FEL) with a planar undulator holds a potential for generation of relatively strong coherent radiation at the third harmonic of the fundamental frequency. Here we present detailed study of the nonlinear harmonic generation in the SASE FEL obtained with time-dependent FEL simulation code. Using similarity techniques we present universal dependencies for temporal, spectral, and statistical properties of the odd harmonics of the radiation from SASE FEL. In particular, we derived universal formulae for radiation power of the odd harmonics at saturation. It was also found that coherence time at saturation falls inversely proportional to harmonic number, and relative spectrum bandwidth remains constant with harmonic number.
△ Less
Submitted 20 September, 2005;
originally announced September 2005.
-
Exact Solution for the Second Harmonic Generation in XFELs
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
The generation of harmonic radiation through a non-linear mechanism driven by bunching at fundamental frequency is an important option in the operation of high gain Free-Electron Lasers (FELs). The use of harmonic generation at a large scale facility may result in achieving shorter radiation wavelengths for the same electron beam energy. This paper describes a theory of second harmonic generatio…
▽ More
The generation of harmonic radiation through a non-linear mechanism driven by bunching at fundamental frequency is an important option in the operation of high gain Free-Electron Lasers (FELs). The use of harmonic generation at a large scale facility may result in achieving shorter radiation wavelengths for the same electron beam energy. This paper describes a theory of second harmonic generation in planar undulators with particular attention to X-Ray FELs (XFELs). Our study is based on an exact analytical solution of Maxwell equations, derived with the help of the Green's function method. On the contrary, up-to-date theoretical understanding of the second harmonic generation is only limited to some estimation of the total radiation power based on the source part of the wave equation. Moreover, we find that such part of the wave equation is presented with several incorrect manipulations among which is the omission of an important contribution. Our work yields correct parametric dependencies and specific predictions of additional properties such as polarization, angular distribution of the radiation intensity and total power. The most surprising prediction is the presence of a vertically polarized part of the second harmonic radiation, whereas up-to-date understanding assumes that the field is horizontally polarized. Altogether, this paper presents the first correct theory of second harmonic generation for high gain FELs.
△ Less
Submitted 8 August, 2005;
originally announced August 2005.
-
Understanding transverse coherence properties of X-ray beams in third generation Synchrotron Radiation sources
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
This paper describes a theory of transverse coherence properties of Undulator Radiation. Our study is of very practical relevance, because it yields specific predictions of Undulator Radiation cross-spectral density in various parts of the beamline. On the contrary, usual estimations of coherence properties assume that the undulator source is quasi-homogeneous, like thermal sources, and rely on…
▽ More
This paper describes a theory of transverse coherence properties of Undulator Radiation. Our study is of very practical relevance, because it yields specific predictions of Undulator Radiation cross-spectral density in various parts of the beamline. On the contrary, usual estimations of coherence properties assume that the undulator source is quasi-homogeneous, like thermal sources, and rely on the application of van Cittert-Zernike (VCZ) theorem, in its original or generalized form, for calculating transverse coherence length in the far-field approximation. The VCZ theorem is derived in the frame of Statistical Optics using a number of restrictive assumptions: in particular, the quasi-homogeneous assumption is demonstrated to be inaccurate in many practical situations regarding undulator sources. We propose a technique to calculate the cross-spectral density from undulator sources in the most general case. Also, we find the region of applicability of the quasi-homogeneous model and we present an analytical expression for the cross-spectral density which is valid up to the exit of the undulator. For the case of more general undulator sources, simple formulas for the transverse coherence length, interpolated from numerical calculations and suitable for beamline design applications are found. Finally, using a simple vertical slit, we show how transverse coherence properties of an X-ray beam can be manipulated to obtain a larger coherent spot-size on a sample. This invention was devised almost entirely on the basis of theoretical ideas developed throughout this paper.
△ Less
Submitted 30 June, 2005;
originally announced June 2005.
-
Paraxial Green's functions in Synchrotron Radiation theory
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
This work contains a systematic treatment of single particle Synchrotron Radiation and some application to realistic beams with given cross section area, divergence and energy spread. Standard theory relies on several approximations whose applicability limits and accuracy are often forgotten. We begin remarking that on the one hand, a paraxial approximation can always be applied without loss of…
▽ More
This work contains a systematic treatment of single particle Synchrotron Radiation and some application to realistic beams with given cross section area, divergence and energy spread. Standard theory relies on several approximations whose applicability limits and accuracy are often forgotten. We begin remarking that on the one hand, a paraxial approximation can always be applied without loss of generality and with ultra relativistic accuracy. On the other hand, dominance of the acceleration field over the velocity part in the Lienard-Wiechert expressions is not always granted and constitutes a separate assumption, whose applicability is discussed. Treating Synchrotron Radiation in paraxial approximation we derive the equation for the slow varying envelope function of the Fourier components of the electric field vector. Calculations of Synchrotron Radiation properties performed by others showed that the phase of the Fourier components of the electric field vector differs from the phase of a virtual point source. In this paper we present a systematic, analytical description of this phase shift, calculating amplitude and phase of electric field from bending magnets, short magnets, two bending magnet system separated by a straight section (edge radiation) and undulator devices. We pay particular attention to region of applicability and accuracy of approximations used. Finally, taking advantage of results of analytical calculation presented in reduced form we analyze various features of radiation from a complex insertion device (set of two undulators with a focusing triplet in between) accounting for the influence of energy spread and electron beam emittance.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.
-
A simple method for the determination of the structure of ultrashort relativistic electron bunches
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
In this paper we propose a new method for measurements of the longitudinal profile of 100 femtosecond electron bunches for X-ray Free Electron Lasers (XFELs). The method is simply the combination of two well-known techniques, which where not previously combined to our knowledge. We use seed 10-ps 1047 nm quantum laser to produce exact optical replica of ultrafast electron bunches. The replica is…
▽ More
In this paper we propose a new method for measurements of the longitudinal profile of 100 femtosecond electron bunches for X-ray Free Electron Lasers (XFELs). The method is simply the combination of two well-known techniques, which where not previously combined to our knowledge. We use seed 10-ps 1047 nm quantum laser to produce exact optical replica of ultrafast electron bunches. The replica is generated in apparatus which consists of an input undulator (energy modulator), and the short output undulator (radiator) separated by a dispersion section. The radiation in the output undulator is excited by the electron bunch modulated at the optical wavelength and rapidly reaches 100 MW-level peak power. We then use the now-standard method of ultrashort laser pulse-shape measurement, a tandem combination of autocorrelator and spectrum (FROG -- frequency resolved optical gating). The FROG trace of the optical replica of electron bunch gives accurate and rapid electron bunch shape measurements in a way similar to a femtosecond oscilloscope. Real-time single-shot measurements of the electron bunch structure could provide significant information about physical mechanisms responsible for generation ultrashort electron bunches in bunch compressors. The big advantage of proposed technique is that it can be used to determine the slice energy spread and emittance in multishot measurements. It is possible to measure bunch structure completely, that is to measure peak current, energy spread and transverse emittance as a function of time. We illustrate with numerical examples the potential of the proposed method for electron beam diagnostics at the European X-ray FEL.
△ Less
Submitted 15 July, 2004;
originally announced July 2004.
-
Theory of space-charge waves on gradient-profile relativistic electron beam: an analysis in propagating eigenmodes
Authors:
Gianluca Geloni,
Evgeni Saldin,
Evgeni Schneidmiller,
Mikhail Yurkov
Abstract:
We developed an exact analytical treatment for space-charge waves within a relativistic electron beam in terms of (self-reproducing) propagating eigenmodes. This result is of obvious theoretical relevance as it constitutes one of the few exact solution for the evolution of charged particles under the action of self-interactions. It also has clear numerical applications in particle accelerator ph…
▽ More
We developed an exact analytical treatment for space-charge waves within a relativistic electron beam in terms of (self-reproducing) propagating eigenmodes. This result is of obvious theoretical relevance as it constitutes one of the few exact solution for the evolution of charged particles under the action of self-interactions. It also has clear numerical applications in particle accelerator physics where it can be used as the first self-consistent benchmark for space-charge simulation programs. Today our work is of practical relevance in FEL technology in relation with all those schemes where an optically modulated electron beam is needed and with the study of longitudinal space-charge instabilities in magnetic bunch compressors.
△ Less
Submitted 5 July, 2004;
originally announced July 2004.
-
A new technique to generate 100 GW-level attosecond X-ray pulses from the X-ray SASE FELs
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We propose a scheme for generation of single 100 GW 300-as pulse in the X-ray free electron laser with the use of a few cycles optical pulse from Ti:sapphire laser system. Femtosecond optical pulse interacts with the electron beam in the two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the elect…
▽ More
We propose a scheme for generation of single 100 GW 300-as pulse in the X-ray free electron laser with the use of a few cycles optical pulse from Ti:sapphire laser system. Femtosecond optical pulse interacts with the electron beam in the two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the electron beam enters the first part of the baseline gap-adjustable X-ray undulator and produces SASE radiation with 100 MW-level power. Due to energy modulation the frequency is correlated to the longitudinal position within the few-cycle-driven slice of the SASE radiation pulse. The largest frequency offset corresponds to a single-spike pulse in the time domain which is confined to one half-oscillation period near the central peak electron energy. After the first undulator the electron beam is guided through a magnetic delay which we use to position the X-ray spike with the largest frequency offset at the "fresh" part of the electron bunch. After the chicane the electron beam and the radiation produced in the first undulator enter the second undulator which is resonant with the offset frequency. In the second undulator the seed radiation at reference frequency plays no role, and only a single (300 as duration) spike grows rapidly. The final part of the undulator is a tapered section allowing to achieve maximum output power 100-150 GW in 0.15 nm wavelength range. Attosecond X-ray pulse is naturally synchronized with its fs optical pulse which reveals unique perspective for pump-probe experiments with sub-femtosecond resolution.
△ Less
Submitted 11 March, 2004;
originally announced March 2004.
-
Design formulas for short-wavelength FELs
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Simple formulas for optimization of VUV and X-ray SASE FELs are presented. The FEL gain length and the optimal beta-function are explicitly expressed in terms of the electron beam and undulator parameters. The FEL saturation length is estimated taking into account quantum diffusion in the undulator. Examples of the FEL optimization are given. Parameters of a SASE FEL, operating at the Compton wa…
▽ More
Simple formulas for optimization of VUV and X-ray SASE FELs are presented. The FEL gain length and the optimal beta-function are explicitly expressed in terms of the electron beam and undulator parameters. The FEL saturation length is estimated taking into account quantum diffusion in the undulator. Examples of the FEL optimization are given. Parameters of a SASE FEL, operating at the Compton wavelength, are suggested.
△ Less
Submitted 27 January, 2004;
originally announced January 2004.
-
Terawatt-scale sub-10-fs laser technology - key to generation of GW-level attosecond pulses in X-ray free electron laser
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
We propose a technique for the production of attosecond X-ray pulses which is based on the use of X-ray SASE FEL combined with a femtosecond laser system. A few-cycle optical pulse from a Ti:sapphire laser interacts with the electron beam in a two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the…
▽ More
We propose a technique for the production of attosecond X-ray pulses which is based on the use of X-ray SASE FEL combined with a femtosecond laser system. A few-cycle optical pulse from a Ti:sapphire laser interacts with the electron beam in a two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the electron beam enters the X-ray undulator and produces SASE radiation. Due to energy modulation the frequency is correlated to the longitudinal position within the few-cycle-driven slice of SASE radiation pulse. The largest frequency offset corresponds to a single-spike pulse in the time domain which is confined to one half-oscillation period near the central peak electron energy. The selection of single-spike pulses is achieved by using a crystal monochromator after the X-ray undulator. Our studies show that the proposed technique is capable to produce 300 attoseconds long single pulses with GW-level output power in the 0.1 nm wavelength range, and is applicable to the European X-Ray Laser Project XFEL and the Linac Coherent Light Source at SLAC.
△ Less
Submitted 27 January, 2004;
originally announced January 2004.
-
Start-to-End Simulations of SASE FEL at the TESLA Test Facility, Phase 1
Authors:
M. Dohlus,
K. Floettmann,
O. S. Kozlov,
T. Limberg,
Ph. Piot,
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
Phase 1 of the vacuum ultra-violet (VUV) free-electron laser (FEL) at the TESLA Test Facility (TTF) recently concluded operation. It successfully demonstrated the saturation of a SASE FEL in the in the wavelength range of 80-120 nm. We present a posteriori start-to-end numerical simulations of this FEL. These simulations are based on the programs Astra and elegant for the generation and transpor…
▽ More
Phase 1 of the vacuum ultra-violet (VUV) free-electron laser (FEL) at the TESLA Test Facility (TTF) recently concluded operation. It successfully demonstrated the saturation of a SASE FEL in the in the wavelength range of 80-120 nm. We present a posteriori start-to-end numerical simulations of this FEL. These simulations are based on the programs Astra and elegant for the generation and transport of the electron distribution. An independent simulation of the intricate beam dynamics in the magnetic bunch compressor is performed with the program CSRtrack. The SASE FEL process is simulated with the code FAST. From our detailed simulations and the resulting phase space distribution at the undulator entrance, we found that the FEL was driven only by a small fraction (slice) of the electron bunch. This "lasing slice" is located in the head of the bunch, and has a peak current of approximately 3 kA. A strong energy chirp (due to the space charge field after compression) within this slice had a significant influence on the FEL operation. Our study shows that the radiation pulse duration is about 40 fs (FWHM) with a corresponding peak power of 1.5 GW. The simulated FEL properties are compared with various experimental data and found to be in excellent agreement.
△ Less
Submitted 11 December, 2003;
originally announced December 2003.
-
Misconceptions regarding the cancellation of self-forces in the transverse equation of motion for an electron in a bunch
Authors:
G. Geloni,
E. Saldin,
E. Schneidmiller,
M. Yurkov
Abstract:
As a consequence of motions driven by external forces, self-fields originate within an electron bunch, which are different from the static case. In the case of magnetic external forces acting on an ultrarelativistic beam, the longitudinal self-interactions are responsible for CSR (Coherent Synchrotron Radiation)-related phenomena, which have been studied extensively. On the other hand, transvers…
▽ More
As a consequence of motions driven by external forces, self-fields originate within an electron bunch, which are different from the static case. In the case of magnetic external forces acting on an ultrarelativistic beam, the longitudinal self-interactions are responsible for CSR (Coherent Synchrotron Radiation)-related phenomena, which have been studied extensively. On the other hand, transverse self-interactions are present too. At the time being, several existing theoretical analysis of transverse dynamics rely on the so-called cancellation effect, which has been around for more than ten years. In this paper we explain why in our view such an effect is not of practical nor of theoretical importance.
△ Less
Submitted 27 October, 2003;
originally announced October 2003.
-
The Free Electron Laser Klystron Amplifier Concept
Authors:
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
The simplest high gain free electron laser (FEL) amplifier concept is proposed. A klystron amplifier has the useful property that the various electronic processes take place in separate portions of the amplifier, rather than overlapping as in FEL amplifier with an uniform undulator. The klystron consists of two fundamental parts: succession of 2-3 cascades (modulator), and an output undulator (r…
▽ More
The simplest high gain free electron laser (FEL) amplifier concept is proposed. A klystron amplifier has the useful property that the various electronic processes take place in separate portions of the amplifier, rather than overlapping as in FEL amplifier with an uniform undulator. The klystron consists of two fundamental parts: succession of 2-3 cascades (modulator), and an output undulator (radiator) in which the modulated electron beam coherently radiates. Each cascade consists of uniform undulator and dispersion section. Unlike distributed optical klystrons, we have a high gain per cascade pass. This has a few consequences. First, klystron gain does not depend on the bunch compression in the injector linac, i.e. maximum gain per cascade pass at high peak beam current is the same as at low peak beam current, without compression. Conventional, short-wavelength FEL amplifier and distributed optical klystron require electron beam peak current of a few kA. Second, there are no requirements on the alignment of the cascade undulators and dispersion sections, because, in our (high gain) case, there is no need for radiation phase matching. There are applications, like XFELs, where the unique properties of high gain klystron FEL amplifier are very desirable. Such a scheme allows one to decrease the total length of the magnetic system. In this paper we discuss also implementation of the proposed SASE FEL scheme for the frequency multiplier, for femtosecond experiments, and multi-user soft X-ray facility.
△ Less
Submitted 14 August, 2003;
originally announced August 2003.
-
Efficient frequency doubler for the soft X-ray SASE FEL at the TESLA Test Facility
Authors:
J. Feldhaus,
M. Koerfer,
T. Moeller,
J. Pflueger,
E. L. Saldin,
E. A. Schneidmiller,
M. V. Yurkov
Abstract:
This paper describes an effective frequency doubler scheme for SASE free electron lasers. It consists of an undulator tuned to the first harmonic, a dispersion section, and a tapered undulator tuned to the second harmonic. The first stage is a conventional soft X-ray SASE FEL. Its gain is controlled in such a way that the maximum energy modulation of the electron beam at the exit is about equal…
▽ More
This paper describes an effective frequency doubler scheme for SASE free electron lasers. It consists of an undulator tuned to the first harmonic, a dispersion section, and a tapered undulator tuned to the second harmonic. The first stage is a conventional soft X-ray SASE FEL. Its gain is controlled in such a way that the maximum energy modulation of the electron beam at the exit is about equal to the local energy spread, but still far away from saturation. When the electron bunch passes through the dispersion section this energy modulation leads to effective compression of the particles. Then the bunched electron beam enters the tapered undulator and produces strong radiation in the process of coherent deceleration. We demonstrate that a frequency doubler scheme can be integrated into the SASE FEL at the TESLA Test Facility at DESY, and will allow to reach 3 nm wavelength with GW-level of output peak power. This would extend the operating range of the FEL into the so-called water window and significantly expand the capabilities of the TTF FEL user facility.
△ Less
Submitted 18 July, 2003;
originally announced July 2003.
-
Two-color FEL amplifier for femtosecond-resolution pump-probe experiments with GW-scale X-ray and optical pulses
Authors:
J. Feldhaus,
M. Koerfer,
T. Moeller,
J. Pflueger,
E. L. Saldin,
E. A. Schneidmiller,
S. Schreiber,
M. V. Yurkov
Abstract:
Pump-probe experiments combining pulses from a X-ray FEL and an optical femtosecond laser are very attractive for sub-picosecond time-resolved studies. Since the synchronization between the two independent light sources to an accuracy of 100 fs is not yet solved, it is proposed to derive both femtosecond radiation pulses from the same electron bunch but from two insertion devices. This eliminate…
▽ More
Pump-probe experiments combining pulses from a X-ray FEL and an optical femtosecond laser are very attractive for sub-picosecond time-resolved studies. Since the synchronization between the two independent light sources to an accuracy of 100 fs is not yet solved, it is proposed to derive both femtosecond radiation pulses from the same electron bunch but from two insertion devices. This eliminates the need for synchronization and developing a tunable high power femtosecond quantum laser. In the proposed scheme a GW-level soft X-ray pulse is naturally synchronized with a GW-level optical pulse, independent of any jitter in the arrival time of the electron bunches. The concept is based on the generation of optical radiation in a master oscillator-power FEL amplifier (MOPA) configuration. X-ray radiation is generated in an X-ray undulator inserted between the modulator and radiator sections of the optical MOPA scheme. An attractive feature of the FEL amplifier scheme is the absence of any apparent limitations which could prevent operation in the femtosecond regime in a wide (200-900 nm) wavelength range. A commercially available long (nanosecond) pulse dye laser can be used as seed laser.
△ Less
Submitted 18 July, 2003;
originally announced July 2003.