-
Optical wavefront shaping in deep tissue using photoacoustic feedback
Authors:
Fei Xia,
Ivo Leite,
Robert Prevedel,
Thomas Chaigne
Abstract:
Over the past decade, optical wavefront shaping has been developed to focus light through highly opaque scattering layers, opening new possibilities for biomedical applications. To probe light intensity deep inside soft scattering media such as biological tissues, internal guide-stars are required. Here, we give an overview of the main principles and describe in depth the use of a photoacoustic fe…
▽ More
Over the past decade, optical wavefront shaping has been developed to focus light through highly opaque scattering layers, opening new possibilities for biomedical applications. To probe light intensity deep inside soft scattering media such as biological tissues, internal guide-stars are required. Here, we give an overview of the main principles and describe in depth the use of a photoacoustic feedback signal for this purpose. We further present first principles calculations and simulations to estimate important experimental parameters, and detailed instructions on designing and conducting these experiments. Finally, we provide guidance towards selecting suitable equipment for building a typical experimental setup, paving the way for further innovative biomedical imaging and therapy applications.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
Deep mouse brain two-photon near-infrared fluorescence imaging using a superconducting nanowire single-photon detector array
Authors:
Amr Tamimi,
Martin Caldarola,
Sebastian Hambura,
Juan C. Boffi,
Niels Noordzij,
Johannes W. N. Los,
Antonio Guardiani,
Hugo Kooiman,
Ling Wang,
Christian Kieser,
Florian Braun,
Andreas Fognini,
Robert Prevedel
Abstract:
Two-photon microscopy (2PM) has become an important tool in biology to study the structure and function of intact tissues in-vivo. However, adult mammalian tissues such as the mouse brain are highly scattering, thereby putting fundamental limits on the achievable imaging depth, which typically resides around 600-800um. In principle, shifting both the excitation as well as (fluorescence) emission l…
▽ More
Two-photon microscopy (2PM) has become an important tool in biology to study the structure and function of intact tissues in-vivo. However, adult mammalian tissues such as the mouse brain are highly scattering, thereby putting fundamental limits on the achievable imaging depth, which typically resides around 600-800um. In principle, shifting both the excitation as well as (fluorescence) emission light to the shortwave near-infrared (SWIR, 1000-1700 nm) region promises substantially deeper imaging in 2PM, yet has proven challenging in the past due to the limited availability of detectors and probes in this wavelength region. To overcome these limitations and fully capitalize on the SWIR region, in this work we introduce a novel array of superconducting nanowire single-photon detectors (SNSPDs) and associated custom detection electronics for the use in near-infrared 2PM. The SNSPD array exhibits high efficiency and dynamic range, as well as low dark-count rates over a wide wavelength range. Additionally, the electronics and software permit seamless integration into typical 2PM systems. Together with a fluorescent dye emitting at 1105 nm, we report imaging depth of > 1.1mm in the in-vivo mouse brain, limited only by available labeling density and laser power. Our work further establishes SWIR 2PM approaches and SNSPDs as promising technologies for deep tissue biological imaging.
△ Less
Submitted 21 December, 2023;
originally announced December 2023.
-
Comparing free-space and fibre-coupled detectors for Fabry-Pérot based all-optical photoacoustic tomography
Authors:
Jakub Czuchnowski,
Robert Prevedel
Abstract:
All-optical ultrasound detection bears unique advantages for photoacoustics, including wider detection bandwidth, higher signal-to-noise per unit area and lower susceptibility to electromagnetic noise. These benefits have established optical ultrasound detection as a key method for photoacoustic applications in biology and medicine. However, the use of free-space detectors renders this approach se…
▽ More
All-optical ultrasound detection bears unique advantages for photoacoustics, including wider detection bandwidth, higher signal-to-noise per unit area and lower susceptibility to electromagnetic noise. These benefits have established optical ultrasound detection as a key method for photoacoustic applications in biology and medicine. However, the use of free-space detectors renders this approach sensitive to optical aberrations, which can degrade the pressure sensitivity and result in deteriorated image quality. While spatial mode-filtering through fibers has been proposed to alleviate these problems in Fabry-Pérot based pressure sensors, their real functional advantage has never been properly investigated. In this paper we rigorously and quantitatively compare the performance of free-space and fibre-coupled detectors in a custom correlative setup. We demonstrate the superiority of the latter in terms of both signal level and image quality in realistic all-optical photoacoustic tomography settings.
△ Less
Submitted 6 December, 2021;
originally announced December 2021.
-
Zernike mode rescaling extends capabilities of adaptive optics for microscopy
Authors:
Jakub Czuchnowski,
Robert Prevedel
Abstract:
Zernike polynomials are widely used mathematical models of experimentally observed optical aberrations. Their useful mathematical properties, in particular their orthogonality, make them a ubiquitous basis set for solving various problems in beam optics. Thus they have found widespread use in adaptive optics realizations that are used to correct wavefront aberrations. However, Zernike aberrations…
▽ More
Zernike polynomials are widely used mathematical models of experimentally observed optical aberrations. Their useful mathematical properties, in particular their orthogonality, make them a ubiquitous basis set for solving various problems in beam optics. Thus they have found widespread use in adaptive optics realizations that are used to correct wavefront aberrations. However, Zernike aberrations lose their orthogonality when used in combination with Gaussian beams, which are omnipresent in real-world optical applications. As a consequence, Zernike aberrations in Gaussian beams start to cross-couple between each other, a phenomenon that does not occur for Zernike aberrations in plane waves. Here, we describe how the aberration radius influences this cross-coupling of Zernike aberrations. Furthermore, we propose that this effect can actually be harnessed to allow efficient compensation of higher-order aberrations using only low-order Zernike modes. This finding has important practical implications, as it suggests the possibility of using adaptive optics devices with low element numbers to compensate aberrations which would normally require more complex and expensive devices.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Transfer function asymmetry in Fabry-Pérot based optical pressure sensors
Authors:
Jakub Czuchnowski,
Robert Prevedel
Abstract:
Optical resonators are one of the most promising optical devices for manufacturing high-performance pressure sensors for photoacoustic imaging. Among these, Fabry-Pérot (FP) based pressure sensors have been successfully used for a multitude of applications. However, critical performance aspects of FP based pressure sensors have not been extensively studied, including the effects system parameters…
▽ More
Optical resonators are one of the most promising optical devices for manufacturing high-performance pressure sensors for photoacoustic imaging. Among these, Fabry-Pérot (FP) based pressure sensors have been successfully used for a multitude of applications. However, critical performance aspects of FP based pressure sensors have not been extensively studied, including the effects system parameters such as beam diameter and cavity misalignment have on transfer function shape. Here, we discuss the possible origins of the transfer function asymmetry, the impact it has on measurement sensitivity as well as ways to correctly estimate the FP pressure sensitivity under practical experimental conditions.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Cross-compensation of Zernike aberrations in Gaussian optics
Authors:
Jakub Czuchnowski,
Robert Prevedel
Abstract:
Zernike polynomials are one of the most widely used mathematical descriptors of optical aberrations in the fields of imaging and adaptive optics. Their mathematical orthogonality as well as isomorphisms with experimentally observable aberrations make them a very powerful tool in solving numerous problems in beam optics. However, Zernike aberrations show cross-coupling between individual modes when…
▽ More
Zernike polynomials are one of the most widely used mathematical descriptors of optical aberrations in the fields of imaging and adaptive optics. Their mathematical orthogonality as well as isomorphisms with experimentally observable aberrations make them a very powerful tool in solving numerous problems in beam optics. However, Zernike aberrations show cross-coupling between individual modes when used in combination with Gaussian beams, an effect that has not been extensively studied. Here we propose a novel framework that is capable of explaining the fundamental cross-compensation of Zernike type aberrations, both in low-aberration and high-aberration regimes. Our approach is based on analysing the coupling between Zernike modes and different classes of Laguerre-Gauss modes which allows investigating aberrated beams not only on a single plane but also during their 3D propagation.
△ Less
Submitted 10 February, 2021;
originally announced February 2021.
-
Improving the sensitivity of planar Fabry-Pérot cavities via adaptive optics and mode filtering
Authors:
Jakub Czuchnowski,
Robert Prevedel
Abstract:
Fabry-Pérot (FP) cavities are fundamental and ubiquitous optical elements frequently used in various sensing applications. Here, we introduce a general theoretical framework to study arbitrary light-cavity mode interactions for planar FPs and show how optical aberrations, intrinsic to the interrogating beam or due to imperfect cavities, reduce optical sensitivity by exciting higher-order spatial m…
▽ More
Fabry-Pérot (FP) cavities are fundamental and ubiquitous optical elements frequently used in various sensing applications. Here, we introduce a general theoretical framework to study arbitrary light-cavity mode interactions for planar FPs and show how optical aberrations, intrinsic to the interrogating beam or due to imperfect cavities, reduce optical sensitivity by exciting higher-order spatial modes in the cavity. We find that particular Zernike aberrations play a dominant role in sensitivity degradation, and that the general loss of sensitivity can be significantly recovered by appropriate wavefront correction or mode filtering. We then demonstrate our theoretical findings also experimentally and show that in practice the sensitivity of realistic planar FP sensors can be improved up to three-fold by a synergistic combination of adaptive optics and passive mode filtering.
△ Less
Submitted 19 July, 2020;
originally announced July 2020.
-
Brillouin microscopy - a revolutionary tool for mechanobiology?
Authors:
Robert Prevedel,
Alba Diz-Muñoz,
Giancarlo Ruocco,
Giuseppe Antonacci
Abstract:
The role and importance of mechanical properties of cells and tissues in cellular function, development as well as disease has widely been acknowledged, however standard techniques currently used to assess them exhibit intrinsic limitations. Recently, a new type of optical elastography, namely Brillouin microscopy, has emerged as a non-destructive, label- and contact-free method which can probe th…
▽ More
The role and importance of mechanical properties of cells and tissues in cellular function, development as well as disease has widely been acknowledged, however standard techniques currently used to assess them exhibit intrinsic limitations. Recently, a new type of optical elastography, namely Brillouin microscopy, has emerged as a non-destructive, label- and contact-free method which can probe the viscoelastic properties of biological samples with diffraction-limited resolution in 3D. This has led to increased attention amongst the biological and medical research communities, but also to debates about the interpretation and relevance of the measured physical quantities. Here, we review this emerging technology by describing the underlying biophysical principles and discussing the interpretation of Brillouin spectra arising from heterogeneous biological matter. We further elaborate on the technique's limitations as well as its potential for new insights in biology in order to guide interested researchers from various fields.
△ Less
Submitted 7 January, 2019;
originally announced January 2019.
-
Optimizing and extending light-sculpting microscopy for fast functional imaging in neuroscience
Authors:
Peter Rupprecht,
Robert Prevedel,
Florian Groessl,
Wulf E. Haubensak,
Alipasha Vaziri
Abstract:
A number of questions in systems biology such as understanding how dynamics of neuronal networks are related to brain function require the ability to capture the functional dynamics of large cellular populations at high speed. Recently, this has driven the development of a number of parallel and high speed imaging techniques such as light-sculpting microscopy, which has been used to capture neuron…
▽ More
A number of questions in systems biology such as understanding how dynamics of neuronal networks are related to brain function require the ability to capture the functional dynamics of large cellular populations at high speed. Recently, this has driven the development of a number of parallel and high speed imaging techniques such as light-sculpting microscopy, which has been used to capture neuronal dynamics at the whole brain and single cell level in small model organism. However, the broader applicability of light-sculpting microscopy is limited by the size of volumes for which high speed imaging can be obtained and scattering in brain tissue. Here, we present strategies for optimizing the present tradeoffs in light-sculpting microscopy. Various scanning modalities in light-sculpting microscopy are theoretically and experimentally evaluated, and strategies to maximize the obtainable volume speeds, and depth penetration in brain tissue using different laser systems are provided. Design-choices, important parameters and their trade-offs are experimentally demonstrated by performing calcium-imaging in acute mouse-brain slices. We further show that synchronization of line-scanning techniques with rolling-shutter read-out of the camera can reduce scattering effects and enhance image contrast at depth.
△ Less
Submitted 13 January, 2015;
originally announced January 2015.
-
Brain-wide 3D imaging of neuronal activity in Caenorhabditis elegans with sculpted light
Authors:
Tina Schrödel,
Robert Prevedel,
Karin Aumayr,
Manuel Zimmer,
Alipasha Vaziri
Abstract:
Recent efforts in neuroscience research seek to obtain detailed anatomical neuronal wiring maps as well as information on how neurons in these networks engage in dynamic activities. Although the entire connectivity map of the nervous system of C. elegans has been known for more than 25 years, this knowledge has not been sufficient to predict all functional connections underlying behavior. To appro…
▽ More
Recent efforts in neuroscience research seek to obtain detailed anatomical neuronal wiring maps as well as information on how neurons in these networks engage in dynamic activities. Although the entire connectivity map of the nervous system of C. elegans has been known for more than 25 years, this knowledge has not been sufficient to predict all functional connections underlying behavior. To approach this goal, we developed a two-photon technique for brain-wide calcium imaging in C. elegans using wide-field temporal focusing (WF-TEFO). Pivotal to our results was the use of a nuclear-localized, genetically encoded calcium indicator (NLS-GCaMP5K) that permits unambiguous discrimination of individual neurons within the densely-packed head ganglia of C. elegans. We demonstrate near-simultaneous recording of activity of up to 70% of all head neurons. In combination with a lab-on-a-chip device for stimulus delivery, this method provides an enabling platform for establishing functional maps of neuronal networks.
△ Less
Submitted 6 June, 2014;
originally announced June 2014.
-
Simultaneous whole-animal 3D-imaging of neuronal activity using light field microscopy
Authors:
R. Prevedel,
Y. -G. Yoon,
M. Hoffmann,
N. Pak,
G. Wetzstein,
S. Kato,
T. Schrödel,
R. Raskar,
M. Zimmer,
E. S. Boyden,
A. Vaziri
Abstract:
3D functional imaging of neuronal activity in entire organisms at single cell level and physiologically relevant time scales faces major obstacles due to trade-offs between the size of the imaged volumes, and spatial and temporal resolution. Here, using light-field microscopy in combination with 3D deconvolution, we demonstrate intrinsically simultaneous volumetric functional imaging of neuronal p…
▽ More
3D functional imaging of neuronal activity in entire organisms at single cell level and physiologically relevant time scales faces major obstacles due to trade-offs between the size of the imaged volumes, and spatial and temporal resolution. Here, using light-field microscopy in combination with 3D deconvolution, we demonstrate intrinsically simultaneous volumetric functional imaging of neuronal population activity at single neuron resolution for an entire organism, the nematode Caenorhabditis elegans. The simplicity of our technique and possibility of the integration into epi-fluoresence microscopes makes it an attractive tool for high-speed volumetric calcium imaging.
△ Less
Submitted 22 December, 2014; v1 submitted 21 January, 2014;
originally announced January 2014.