Color-map recommendation for MR relaxometry maps
Authors:
Miha Fuderer,
Barbara Wichtmann,
Fabio Crameri,
Nandita M. deSouza,
Bettina Baeßler,
Vikas Gulani,
Meiyun Wang,
Dirk Poot,
Ruud de Boer,
Matt Cashmore,
Wolter de Graaf,
Kathryn E. Keenan,
Dan Ma,
Carolin Pirkl,
Nico Sollmann,
Sebastian Weingärtner,
Stefano Mandija,
Xavier Golay
Abstract:
Purpose: To harmonize the use of color for MR relaxometry maps and therefore recommend the use of specific color-maps for representing T1 and T2 maps. Methods: Perceptually linearized color-maps were chosen to have similar color settings as those proposed by Griswold et al. in 2018. A Delphi process, polling the opinion of a panel of 81 experts, was used to generate consensus on the suitability of…
▽ More
Purpose: To harmonize the use of color for MR relaxometry maps and therefore recommend the use of specific color-maps for representing T1 and T2 maps. Methods: Perceptually linearized color-maps were chosen to have similar color settings as those proposed by Griswold et al. in 2018. A Delphi process, polling the opinion of a panel of 81 experts, was used to generate consensus on the suitability of these maps. Results: Consensus was reached on the suitability of the logarithm-processed Lipari color-map for T1 and the logarithm-processed Navia color-map for T2. There was consensus on color bars being mandatory and on the use of a specific value indicating invalidity. There was no consensus on whether the ranges should be fixed per anatomy. Conclusion: The authors recommend the use of the logarithm-processed Lipari color map for displaying quantitative T1 maps and R1 maps; likewise, the authors recommend the logarithm-processed Navia color-map for displaying T2, T2*, R2 and R2* maps.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
An Efficient Method for Multi-Parameter Mapping in Quantitative MRI using B-Spline Interpolation
Authors:
Willem van Valenberg,
Stefan Klein,
Frans M. Vos,
Kirsten Koolstra,
Lucas J. van Vliet,
Dirk H. J. Poot
Abstract:
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid, as used in MR Fingerprinting. However, accurate estimation requires discr…
▽ More
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid, as used in MR Fingerprinting. However, accurate estimation requires discretizing each parameter with a high resolution and consequently high computational and memory costs for dictionary generation, storage, and matching. Here, we reduce the required parameter resolution by approximating the signal between grid points through B-spline interpolation. The interpolant and its gradient are evaluated efficiently which enables a least-squares fitting method for parameter mapping. The resolution of each parameter was minimized while obtaining a user-specified interpolation accuracy. The method was evaluated by phantom and in-vivo experiments using fully-sampled and undersampled unbalanced (FISP) MR fingerprinting acquisitions. Bloch simulations incorporated relaxation effects ($T_1,T_2$), proton density ($PD$), receiver phase ($φ_0$), transmit field inhomogeneity ($B_1^+$), and slice profile. Parameter maps were compared with those obtained from dictionary matching, where the parameter resolution was chosen to obtain similar signal (interpolation) accuracy. For both the phantom and the in-vivo acquisition, the proposed method approximated the parameter maps obtained through dictionary matching while reducing the parameter resolution in each dimension ($T_1,T_2,B_1^+$) by, on average, an order of magnitude. In effect, the applied dictionary was reduced from 1.47 GB to 464 KB. Dictionary fitting with B-spline interpolation reduces the computational and memory costs of dictionary-based methods and is therefore a promising method for multi-parametric mapping.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
APIR-Net: Autocalibrated Parallel Imaging Reconstruction using a Neural Network
Authors:
Chaoping Zhang,
Florian Dubost,
Marleen de Bruijne,
Stefan Klein,
Dirk H. J. Poot
Abstract:
Deep learning has been successfully demonstrated in MRI reconstruction of accelerated acquisitions. However, its dependence on representative training data limits the application across different contrasts, anatomies, or image sizes. To address this limitation, we propose an unsupervised, auto-calibrated k-space completion method, based on a uniquely designed neural network that reconstructs the f…
▽ More
Deep learning has been successfully demonstrated in MRI reconstruction of accelerated acquisitions. However, its dependence on representative training data limits the application across different contrasts, anatomies, or image sizes. To address this limitation, we propose an unsupervised, auto-calibrated k-space completion method, based on a uniquely designed neural network that reconstructs the full k-space from an undersampled k-space, exploiting the redundancy among the multiple channels in the receive coil in a parallel imaging acquisition. To achieve this, contrary to common convolutional network approaches, the proposed network has a decreasing number of feature maps of constant size. In contrast to conventional parallel imaging methods such as GRAPPA that estimate the prediction kernel from the fully sampled autocalibration signals in a linear way, our method is able to learn nonlinear relations between sampled and unsampled positions in k-space. The proposed method was compared to the start-of-the-art ESPIRiT and RAKI methods in terms of noise amplification and visual image quality in both phantom and in-vivo experiments. The experiments indicate that APIR-Net provides a promising alternative to the conventional parallel imaging methods, and results in improved image quality especially for low SNR acquisitions.
△ Less
Submitted 19 September, 2019;
originally announced September 2019.
-
Diffusion MRI microstructure models with in vivo human brain Connectom data: results from a multi-group comparison
Authors:
Uran Ferizi,
Benoit Scherrer,
Torben Schneider,
Mohammad Alipoor,
Odin Eufracio,
Rutger H. J. Fick,
Rachid Deriche,
Markus Nilsson,
Ana K. Loya-Olivas,
Mariano Rivera,
Dirk H. J. Poot,
Alonso Ramirez-Manzanares,
Jose L. Marroquin,
Ariel Rokem,
Christian Pötter,
Robert F. Dougherty,
Ken Sakaie,
Claudia Wheeler-Kingshott,
Simon K. Warfield,
Thomas Witzel,
Lawrence L. Wald,
José G. Raya,
Daniel C. Alexander
Abstract:
A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International…
▽ More
A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International Symposium on Biomedical Imaging (ISBI) 2015 conference. This competition aimed at identifying the DW-MRI models that best predict unseen DW data. in vivo DW-MRI data was acquired on the Connectom scanner at the A.A.Martinos Center (Massachusetts General Hospital) using gradients strength of up to 300 mT/m and a broad set of diffusion times. We focused on assessing the DW signal prediction in two regions: the genu in the corpus callosum, where the fibres are relatively straight and parallel, and the fornix, where the configuration of fibres is more complex. The challenge participants had access to three-quarters of the whole dataset, and their models were ranked on their ability to predict the remaining unseen quarter of data. In this paper we provide both an overview and a more in-depth description of each evaluated model, report the challenge results, and infer trends about the model characteristics that were associated with high model ranking. This work provides a much needed benchmark for DW-MRI models. The acquired data and model details for signal prediction evaluation are provided online to encourage a larger scale assessment of diffusion models in the future.
△ Less
Submitted 9 November, 2016; v1 submitted 25 April, 2016;
originally announced April 2016.