-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Multiomics-based Outcome Prediction for the Treatment of Brain Metastases with Personalized Ultra-fractionated Stereotactic Adaptive Radiotherapy (PULSAR)
Authors:
Haozhao Zhang,
Michael Dohopolski,
Strahinja Stojadinovic,
Luiza Giuliani,
Soummitra Anand,
Heejung Kim,
Arnold Pompos,
Andrew Godley,
Steve Jiang,
Tu Dan,
Zabi Wardak,
Robert Timmerman,
Hao Peng
Abstract:
Purpose: We aimed to develop a data-driven multiomics approach integrating radiomics, dosiomics, and delta features to predict treatment response at an earlier stage (intra-treatment) for brain metastases (BMs) patients treated with PULSAR. Methods: We conducted a retrospective study of 39 patients with 69 BMs treated with PULSAR. Radiomics, dosiomics, and delta features were extracted from pretre…
▽ More
Purpose: We aimed to develop a data-driven multiomics approach integrating radiomics, dosiomics, and delta features to predict treatment response at an earlier stage (intra-treatment) for brain metastases (BMs) patients treated with PULSAR. Methods: We conducted a retrospective study of 39 patients with 69 BMs treated with PULSAR. Radiomics, dosiomics, and delta features were extracted from pretreatment and intra-treatment MRI scans and dose distributions. Six individual models and an ensemble feature selection (EFS) model were constructed using SVM and evaluated via stratified 5-fold cross-validation. The classification task distinguished lesions with >20% volume reduction at follow-up. We assessed performance metrics including sensitivity, specificity, accuracy, precision, F1 score, and AUC. Various feature extraction and ensemble selection scenarios were explored to enhance model robustness and reduce overfitting. Results: The EFS model, integrating features from pre-treatment radiomics and dosiomics, intra-treatment radiomics, and delta-radiomics, outperformed six individual models. It achieved an AUC of 0.979, accuracy of 0.917, and F1 score of 0.821. Among the top 9 features, six were derived from post-wavelet transformation, and three from original images. The discrete wavelet transform decomposes volumetric images into multi-resolution components, offering a more comprehensive characterization of underlying structures. Conclusion: Our study demonstrated the feasibility of employing a data-driven multiomics approach to predict tumor volume changes in BMs patients with PULSAR. The EFS model demonstrates enhanced performance compared with six individual models, emphasizing the importance of integrating both pretreatment and intra-treatment data. This application holds promise for optimizing BMs management, potentially mitigating risks associated with under- or over-treatment.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
A manufacturable platform for photonic quantum computing
Authors:
Koen Alexander,
Andrea Bahgat,
Avishai Benyamini,
Dylan Black,
Damien Bonneau,
Stanley Burgos,
Ben Burridge,
Geoff Campbell,
Gabriel Catalano,
Alex Ceballos,
Chia-Ming Chang,
CJ Chung,
Fariba Danesh,
Tom Dauer,
Michael Davis,
Eric Dudley,
Ping Er-Xuan,
Josep Fargas,
Alessandro Farsi,
Colleen Fenrich,
Jonathan Frazer,
Masaya Fukami,
Yogeeswaran Ganesan,
Gary Gibson,
Mercedes Gimeno-Segovia
, et al. (70 additional authors not shown)
Abstract:
Whilst holding great promise for low noise, ease of operation and networking, useful photonic quantum computing has been precluded by the need for beyond-state-of-the-art components, manufactured by the millions. Here we introduce a manufacturable platform for quantum computing with photons. We benchmark a set of monolithically-integrated silicon photonics-based modules to generate, manipulate, ne…
▽ More
Whilst holding great promise for low noise, ease of operation and networking, useful photonic quantum computing has been precluded by the need for beyond-state-of-the-art components, manufactured by the millions. Here we introduce a manufacturable platform for quantum computing with photons. We benchmark a set of monolithically-integrated silicon photonics-based modules to generate, manipulate, network, and detect photonic qubits, demonstrating dual-rail photonic qubits with $99.98\% \pm 0.01\%$ state preparation and measurement fidelity, Hong-Ou-Mandel quantum interference between independent photon sources with $99.50\%\pm0.25\%$ visibility, two-qubit fusion with $99.22\%\pm0.12\%$ fidelity, and a chip-to-chip qubit interconnect with $99.72\%\pm0.04\%$ fidelity, not accounting for loss. In addition, we preview a selection of next generation technologies, demonstrating low-loss silicon nitride waveguides and components, fabrication-tolerant photon sources, high-efficiency photon-number-resolving detectors, low-loss chip-to-fiber coupling, and barium titanate electro-optic phase shifters.
△ Less
Submitted 26 April, 2024;
originally announced April 2024.
-
A component-level co-rotational 3D continuum finite element framework for efficient flexible multibody analysis
Authors:
Ziyun Kan,
Mingdong Chen,
Haijun Peng,
Yizhu Guo,
Xueguan Song
Abstract:
This paper proposes a systematic and novel component level co-rotational (CR) framework, for upgrading existing 3D continuum finite elements to flexible multibody analysis. Without using any model reduction techniques, the high efficiency is achieved through sophisticated operations in both modeling and numerical implementation phrases. In modeling phrase, as in conventional 3D nonlinear finite an…
▽ More
This paper proposes a systematic and novel component level co-rotational (CR) framework, for upgrading existing 3D continuum finite elements to flexible multibody analysis. Without using any model reduction techniques, the high efficiency is achieved through sophisticated operations in both modeling and numerical implementation phrases. In modeling phrase, as in conventional 3D nonlinear finite analysis, the nodal absolute coordinates are used as the system generalized coordinates, therefore simple formulations of the inertia force terms can be obtained. For the elastic force terms, inspired by existing floating frame of reference formulation (FFRF) and conventional element-level CR formulation, a component-level CR modeling strategy is developed. By in combination with Schur complement theory and fully exploring the nature of the component-level CR modeling method, an extremely efficient procedure is developed, which enables us to transform the linear equations raised from each Newton-Raphson iteration step into linear systems with constant coefficient matrix. The coefficient matrix thus can be pre-calculated and decomposed only once, and at all the subsequent time steps only back substitutions are needed, which avoids frequently updating the Jacobian matrix and avoids directly solving the large-scale linearized equation in each iteration. Multiple examples are presented to demonstrate the performance of the proposed framework.
△ Less
Submitted 17 March, 2024;
originally announced March 2024.
-
Understanding the PULSAR Effect in Combined Radiotherapy and Immunotherapy through Attention Mechanisms with a Transformer Model
Authors:
Hao Peng,
Casey Moore,
Debabrata Saha,
Steve Jiang,
Robert Timmerman
Abstract:
PULSAR (personalized, ultra-fractionated stereotactic adaptive radiotherapy) is the adaptation of stereotactic ablative radiotherapy towards personalized cancer management. For the first time, we applied a transformer-based attention mechanism to investigate the underlying interactions between combined PULSAR and PD-L1 blockade immunotherapy based on a murine cancer model (Lewis Lung Carcinoma, LL…
▽ More
PULSAR (personalized, ultra-fractionated stereotactic adaptive radiotherapy) is the adaptation of stereotactic ablative radiotherapy towards personalized cancer management. For the first time, we applied a transformer-based attention mechanism to investigate the underlying interactions between combined PULSAR and PD-L1 blockade immunotherapy based on a murine cancer model (Lewis Lung Carcinoma, LLC). The proposed approach is able to predict the trend of tumor volume change semi-quantitatively, and excels in identifying the potential causal relationships through both self-attention and cross-attention scores.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Unfolding environmental $γ$ flux spectrum with portable CZT detector
Authors:
Taiyuan Liu,
Mingxuan Xue,
Haiping Peng,
Kangkang Zhao,
Deyong Duan,
Yichao Wang,
Changqing Feng,
Yifeng Wei,
Qing Lin,
Zizong Xu,
Xiaolian Wang
Abstract:
Environmental $γ$-rays constitute a crucial source of background in various nuclear, particle and quantum physics experiments. To evaluate the flux rate and the spectrum of $γ$ background, we have developed a novel and straightforward approach to reconstruct the environmental $γ$ flux spectrum by applying a portable CZT $γ$ detector and iterative Bayesian unfolding, which possesses excellent trans…
▽ More
Environmental $γ$-rays constitute a crucial source of background in various nuclear, particle and quantum physics experiments. To evaluate the flux rate and the spectrum of $γ$ background, we have developed a novel and straightforward approach to reconstruct the environmental $γ$ flux spectrum by applying a portable CZT $γ$ detector and iterative Bayesian unfolding, which possesses excellent transferability for broader applications. In this paper, the calibration and GEANT4 Monte-Carlo modeling of the CZT detector, the unfolding procedure as well as the uncertainty estimation are demonstrated in detail. The reconstructed spectrum reveals an environmental $γ$ flux intensity of $3.3\pm 0.9\times 10^{7}$~ (m$^2\cdot$sr$\cdot$hour)$^{-1}$ ranging from 73 to 3033~keV, along with characteristic peaks primarily arising from $^{232}$Th series, $^{238}$U series and $^{40}$K. We also give an instance of background rate evaluation with the unfolded spectrum for validation of the approach.
△ Less
Submitted 5 April, 2024; v1 submitted 22 January, 2024;
originally announced January 2024.
-
Quasi-phase-matched up- and down-conversion in periodically poled layered semiconductors
Authors:
Chiara Trovatello,
Carino Ferrante,
Birui Yang,
Josip Bajo,
Benjamin Braun,
Xinyi Xu,
Zhi Hao Peng,
Philipp K. Jenke,
Andrew Ye,
Milan Delor,
D. N. Basov,
Jiwoong Park,
Philip Walther,
Lee A. Rozema,
Cory Dean,
Andrea Marini,
Giulio Cerullo,
P. James Schuck
Abstract:
Nonlinear optics lies at the heart of classical and quantum light generation. The invention of periodic poling revolutionized nonlinear optics and its commercial applications by enabling robust quasi-phase-matching in crystals such as lithium niobate. However, reaching useful frequency conversion efficiencies requires macroscopic dimensions, limiting further technology development and integration.…
▽ More
Nonlinear optics lies at the heart of classical and quantum light generation. The invention of periodic poling revolutionized nonlinear optics and its commercial applications by enabling robust quasi-phase-matching in crystals such as lithium niobate. However, reaching useful frequency conversion efficiencies requires macroscopic dimensions, limiting further technology development and integration. Here we realize a periodically poled van der Waals semiconductor (3R-MoS$_2$). Due to its exceptional nonlinearity, we achieve macroscopic frequency conversion efficiency over a microscopic thickness of only 1.2$μ$m, $10-100\times$ thinner than current systems with similar performances. Due to unique intrinsic cavity effects, the thickness-dependent quasi-phase-matched second harmonic signal surpasses the usual quadratic enhancement by $50\%$. Further, we report the broadband generation of photon pairs at telecom wavelengths via quasi-phase-matched spontaneous parametric down-conversion. This work opens the new and unexplored field of phase-matched nonlinear optics with microscopic van der Waals crystals, unlocking applications that require simple, ultra-compact technologies such as on-chip entangled photon-pair sources for integrated quantum circuitry and sensing.
△ Less
Submitted 31 December, 2023; v1 submitted 8 December, 2023;
originally announced December 2023.
-
Evaluating residual acceleration noise for TianQin gravitational waves observatory with an empirical magnetic field model
Authors:
Wei Su,
Ze-Bing Zhou,
Yan Wang,
Chen Zhou,
P. F. Chen,
Wei Hong,
J. H. Peng,
Yun Yang,
Y. W. Ni
Abstract:
TianQin (TQ) project plans to deploy three satellites in space around the Earth to measure the displacement change of test masses caused by gravitational waves via laser interferometry. The requirement of the acceleration noise of the test mass is on the order of $10^{-15}~\,{\rm m}\,{\rm s}^{-2}\,{\rm Hz}^{-1/2}$ in the sensitive frequency range of TQ, %the extremely precise acceleration measurem…
▽ More
TianQin (TQ) project plans to deploy three satellites in space around the Earth to measure the displacement change of test masses caused by gravitational waves via laser interferometry. The requirement of the acceleration noise of the test mass is on the order of $10^{-15}~\,{\rm m}\,{\rm s}^{-2}\,{\rm Hz}^{-1/2}$ in the sensitive frequency range of TQ, %the extremely precise acceleration measurement requirements make it necessary to investigate acceleration noise due to space magnetic fields. which is so stringent that the acceleration noise caused by the interaction of the space magnetic field with the test mass needs to be investigated. In this work, by using the Tsyganenko model, a data-based empirical space magnetic field model, we obtain the magnetic field distribution around TQ's orbit spanning two solar cycles in 23 years from 1998 to 2020. With the obtained space magnetic field, we derive the distribution and amplitude spectral densities (ASDs) of the acceleration noise of TQ in 23 years. Our results reveal that the average values of the ratio of the acceleration noise cauesd by the space magnetic field to the requirements of TQ at 1 mHz ($R_{\rm 1mHz}$) and 6 mHz ($R_{\rm 6mHz}$) are 0.123$\pm$0.052 and 0.027$\pm$0.013, respectively. The occurence probabilities of $R_{\rm 1mHz}>0.2$ and $>0.3$ are only 7.9% and 1.2%, respectively, and $R_{\rm 6mHz}$ never exceeds 0.2.
△ Less
Submitted 30 November, 2023; v1 submitted 15 October, 2023;
originally announced October 2023.
-
Simulating the secondary electron avalanche of MCP by Geant4
Authors:
Huaxing Peng,
Baojun Yan,
Han Miao,
Shulin Liu,
Binting Zhang
Abstract:
Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible, while the conventional straight-channel MCP will inevitably have ion feedback, resulting in the sequential after-pulses being the major source of noise. Normal…
▽ More
Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible, while the conventional straight-channel MCP will inevitably have ion feedback, resulting in the sequential after-pulses being the major source of noise. Normally, the problem can be effectively avoided by coupling two straight-channel MCPs in cascade and combining the channels into a `V` shape known as chevron MCPs, but this method is limited by the manufacturing techniques due to the unavoidable gap between the two pieces that will worsen the resolution and peak-to-valley ratio. However, the ion feedback can be inhibited significantly for MCPs with curved channels. Based on Geant4, we investigate how the geometrical parameters of curved-channel MCP influence the gain and get the optimum pore diameter for an MCP to reach the maximum gain with fixed thickness and applied voltage. Additionally, the track-by-track simulation reveals that the average acceleration distance of a secondary electron inside the curved-channel is approximately 20 um when the applied voltage, length-to-diameter ratio and pore diameter are 950 V, 50:1 and 20 um, respectively.
△ Less
Submitted 29 May, 2024; v1 submitted 10 October, 2023;
originally announced October 2023.
-
MCPSim: A Geant4-based generic simulation toolkit for electron multipliers represented by Microchannel Plate
Authors:
Han Miao,
Huaxing Peng,
Baojun Yan,
Shulin Liu,
Hai-Bo Li
Abstract:
The simulation of the instruments based on the cascade multiplication of electrons has always been an important and challenging subject in no matter high energy physics, astrophysics, radiography and other fields. In this work, a generic simulation toolkit is developed based on Geant4, ROOT and CADMesh toolkits for the electron multipliers based on the emission process of secondary electrons, espe…
▽ More
The simulation of the instruments based on the cascade multiplication of electrons has always been an important and challenging subject in no matter high energy physics, astrophysics, radiography and other fields. In this work, a generic simulation toolkit is developed based on Geant4, ROOT and CADMesh toolkits for the electron multipliers based on the emission process of secondary electrons, especially for Microchannel Plate (MCP). Geometry of instruments can be directly imported by standard CAD files and multiple kinds of electromagnetic fields are supported. MCPSim is capable for simulating the general hadronic, weak and electromagnetic processes together with secondary electron emission, which provides a wider range of applications. Users are able to configure the simulation and define the output information by a simple textfile. By comparing with experimental measurements, good agreement is found. MCPSim is expected to guide the design and optimization of such electron multipliers and will be continuously developed and maintained to better satisfy the present and future requirements.
△ Less
Submitted 8 October, 2023;
originally announced October 2023.
-
Basis-set-error-free RPA correlation energies for atoms based on the Sternheimer equation
Authors:
Hao Peng,
Sixian Yang,
Hong Jiang,
Hongming Weng,
Xinguo Ren
Abstract:
The finite basis set errors for all-electron random-phase approximation (RPA) correlation energy calculations are analyzed for isolated atomic systems. We show that, within the resolution-of-identity (RI) RPA framework, the major source of the basis set errors is the incompleteness of the single-particle atomic orbitals used to expand the Kohn-Sham eigenstates, instead of the auxiliary basis set (…
▽ More
The finite basis set errors for all-electron random-phase approximation (RPA) correlation energy calculations are analyzed for isolated atomic systems. We show that, within the resolution-of-identity (RI) RPA framework, the major source of the basis set errors is the incompleteness of the single-particle atomic orbitals used to expand the Kohn-Sham eigenstates, instead of the auxiliary basis set (ABS) to represent the density response function $χ^0$ and the bare Coulomb operator $v$. By solving the Sternheimer equation for the first-order wave function on a dense radial grid, we are able to eliminate the major error -- the incompleteness error of the single-particle atomic basis set -- for atomic RPA calculations. The error stemming from a finite ABS can be readily rendered vanishingly small by increasing the size of the ABS, or by iteratively determining the eigenmodes of the $χ^0 v$ operator. The variational property of the RI-RPA correlation energy can be further exploited to optimize the ABS in order to achieve a fast convergence of the RI-RPA correlation energy. These numerical techniques enable us to obtain basis-set-error-free RPA correlation energies for atoms, and in this work such energies for atoms from H to Kr are presented. The implications of the numerical techniques developed in the present work for addressing the basis set issue for molecules and solids are discussed.
△ Less
Submitted 19 June, 2023;
originally announced June 2023.
-
The background model of the CUPID-Mo $0νββ$ experiment
Authors:
CUPID-Mo Collaboration,
:,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
E. Celi,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa
, et al. (58 additional authors not shown)
Abstract:
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform…
▽ More
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the $2νββ$ decay and other processes with high precision. We also measure the radio-purity of the Li$_{2}$$^{100}$MoO$_4$ crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7$^{+0.9}_{-0.8}$(stat)$^{+1.5}_{-0.7}$(syst)$\times10^{-3}$counts/$Δ$E$_{FWHM}$/mol$_{iso}$/yr, the lowest in a bolometric $0νββ$ decay experiment.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Slice-Less Optical Arbitrary Waveform Measurement (OAWM) in a Bandwidth of More than 600 GHz Using Soliton Microcombs
Authors:
Daniel Drayss,
Dengyang Fang,
Christoph Füllner,
Grigory Lihachev,
Thomas Henauer,
Yung Chen,
Huanfa Peng,
Pablo Marin-Palomo,
Thomas Zwick,
Wolfgang Freude,
Tobias J. Kippenberg,
Sebastian Randel,
Christian Koos
Abstract:
We propose and demonstrate a novel scheme for optical arbitrary waveform measurement (OAWM) that exploits chip-scale Kerr soliton combs as highly scalable multiwavelength local oscillators (LO) for ultra-broadband full-field waveform acquisition. In contrast to earlier concepts, our approach does not require any optical slicing filters and thus lends itself to efficient implementation on state-of-…
▽ More
We propose and demonstrate a novel scheme for optical arbitrary waveform measurement (OAWM) that exploits chip-scale Kerr soliton combs as highly scalable multiwavelength local oscillators (LO) for ultra-broadband full-field waveform acquisition. In contrast to earlier concepts, our approach does not require any optical slicing filters and thus lends itself to efficient implementation on state-of-the-art high-index-contrast integration platforms such as silicon photonics. The scheme allows to measure truly arbitrary waveforms with high accuracy, based on a dedicated system model which is calibrated by means of a femtosecond laser with known pulse shape. We demonstrated the viability of the approach in a proof-of-concept experiment by capturing an optical waveform that contains multiple 16 QAM and 64 QAM wavelength-division multiplexed (WDM) data signals with symbol rates of up to 80 GBd, reaching overall line rates of up to 1.92 Tbit/s within an optical acquisition bandwidth of 610 GHz. To the best of our knowledge, this is the highest bandwidth that has so far been demonstrated in an OAWM experiment.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
STCF Conceptual Design Report: Volume 1 -- Physics & Detector
Authors:
M. Achasov,
X. C. Ai,
R. Aliberti,
L. P. An,
Q. An,
X. Z. Bai,
Y. Bai,
O. Bakina,
A. Barnyakov,
V. Blinov,
V. Bobrovnikov,
D. Bodrov,
A. Bogomyagkov,
A. Bondar,
I. Boyko,
Z. H. Bu,
F. M. Cai,
H. Cai,
J. J. Cao,
Q. H. Cao,
Z. Cao,
Q. Chang,
K. T. Chao,
D. Y. Chen,
H. Chen
, et al. (413 additional authors not shown)
Abstract:
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII,…
▽ More
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII, providing a unique platform for exploring the asymmetry of matter-antimatter (charge-parity violation), in-depth studies of the internal structure of hadrons and the nature of non-perturbative strong interactions, as well as searching for exotic hadrons and physics beyond the Standard Model. The STCF project in China is under development with an extensive R\&D program. This document presents the physics opportunities at the STCF, describes conceptual designs of the STCF detector system, and discusses future plans for detector R\&D and physics case studies.
△ Less
Submitted 5 October, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Statistical Fluid Mechanics: Dynamics Equations and Linear Response Theory
Authors:
Haibing Peng
Abstract:
The statistical nature of discrete fluid molecules with random thermal motion so far has not been considered in mainstream fluid mechanics based on Navier-Stokes equations, wherein fluids have been treated as a continuum breaking into many macroscopically infinitely small (but microscopically large enough) mass elements with their motion only characterized by center-of-mass velocity. Here we provi…
▽ More
The statistical nature of discrete fluid molecules with random thermal motion so far has not been considered in mainstream fluid mechanics based on Navier-Stokes equations, wherein fluids have been treated as a continuum breaking into many macroscopically infinitely small (but microscopically large enough) mass elements with their motion only characterized by center-of-mass velocity. Here we provide a Statistical Mechanical approach to address fluid dynamics by considering statistical velocity distribution of discrete molecules within macroscopically infinitely small volume elements as well as their center-of-mass velocity. Dynamics equations governing the evolution of physical variables have been proposed, Green's functions have been obtained and linear response theory has been applied to study physical situations with external heat perturbation. It is found that the propagation of heat, center-of-mass motion and sound are intrinsically integrated in Statistical fluid dynamics. This work lays down the foundation for applications of Statistical fluid mechanics.
△ Less
Submitted 14 July, 2023; v1 submitted 5 March, 2023;
originally announced March 2023.
-
Message passing approach to analyze the robustness of hypergraph
Authors:
Hao Peng,
Cheng Qian,
Dandan Zhao,
Ming Zhong,
Jianmin Han,
Runchao Li,
Wei Wang
Abstract:
Hypergraph networks are closer to real life because they can reflect higher-order interactions, so researchers have begun using them to build models for real-world networks. The mean-field approach is the current tool for studying the percolation problem on hypergraph networks. However, we found that when there is a loop in the hypergraph network, the calculated results using this approach deviate…
▽ More
Hypergraph networks are closer to real life because they can reflect higher-order interactions, so researchers have begun using them to build models for real-world networks. The mean-field approach is the current tool for studying the percolation problem on hypergraph networks. However, we found that when there is a loop in the hypergraph network, the calculated results using this approach deviate from the real results. Therefore, in this paper, we rephrase the percolation on the hypergraph network as a message passing process, thus obtaining a message passing approach. Our proposed approach has been tested in several hypergraph networks with loops, and the experimental results are more accurate than those under the mean-field approach. This is helpful to analyze and understand the robustness of hypergraph networks with loops. In addition, we also specifically analyzed how four different types of loops affect the accuracy of the experiment. Our proposed message passing approach also provides another way to study percolation on hypergraph networks.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
-
Measurement of reactor thermal neutron fluence of NTD-Ge by activation High-Purity Ge itself
Authors:
Kangkang Zhao,
Mingxuan Xue,
Haiping Peng,
Yunlong Zhang,
Zhiyong Zhang,
Zizong Xu,
Xiaolian Wang
Abstract:
In neutron transmutation doped germanium, the thermal neutron fluence of reactor irradiation is as high as 10$^{18}$~n$\cdot$cm$^{-2}$. For radiological safety reasons, general Co or Au neutron flux monitors cannot be easily used. We have experimentally demonstrated the feasibility of measuring the X-rays emitted by the NTD-Ge itself to determine the absolute thermal neutron fluence for the first…
▽ More
In neutron transmutation doped germanium, the thermal neutron fluence of reactor irradiation is as high as 10$^{18}$~n$\cdot$cm$^{-2}$. For radiological safety reasons, general Co or Au neutron flux monitors cannot be easily used. We have experimentally demonstrated the feasibility of measuring the X-rays emitted by the NTD-Ge itself to determine the absolute thermal neutron fluence for the first time. A Micro-Megas Detector (MMD) and a Silicon Drift Detector (SDD) are set up to detect the tagging KX-rays with 9.2 keV and 10.3 keV cascading from the decays of $^{71}$Ge. Combined the detection efficiencies calculated by GEANT4, neutron fluence results given with proper accuracy by MMD and SDD are in a good agreement with each other.
△ Less
Submitted 24 February, 2023;
originally announced February 2023.
-
A Method for Evaluation of Aerodynamic Lift and Drag Based on Statistical Mechanics
Authors:
Haibing Peng
Abstract:
Despite intensive applications of Navier-Stokes equations in computational-fluid-dynamics (CFD) to understand aerodynamics, fundamental questions remain open since the statistical nature of discrete air molecules with random thermal motion is not considered in CFD. Here we introduce an approach based on Statistical Mechanics, termed as "Volume-Element" method, for numerical evaluation of aerodynam…
▽ More
Despite intensive applications of Navier-Stokes equations in computational-fluid-dynamics (CFD) to understand aerodynamics, fundamental questions remain open since the statistical nature of discrete air molecules with random thermal motion is not considered in CFD. Here we introduce an approach based on Statistical Mechanics, termed as "Volume-Element" method, for numerical evaluation of aerodynamic lift and drag. Pressure and friction as a function of angle of attack have been obtained for canonical flat-plate airfoils, and the method is applicable to convex-shape airfoils directly and viable for concave-shape airfoils if combined with Monte Carlo simulations. This approach opens a door not only for aerodynamic applications, but also for further applications in Boson or Fermi gases.
△ Less
Submitted 25 April, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Coherent subcycle optical shock from superluminal plasma wake
Authors:
H. Peng,
T. W. Huang,
K. Jiang,
R. Li,
C. N. Wu,
M. Y. Yu,
C. Riconda,
S. Weber,
C. T. Zhou,
S. C. Ruan
Abstract:
We propose a new mechanism for generating coherent subcycle optical pulse by directing a relativistic electron beam (REB) into a plasma with a density up-ramp. The subcycle pulse is coherently emitted by bubble-sheath electrons in REB-induced superluminal plasma wake. Using three-dimensional particle-in-cell and far-field time-domain radiation simulations as well as analytical modeling, we show th…
▽ More
We propose a new mechanism for generating coherent subcycle optical pulse by directing a relativistic electron beam (REB) into a plasma with a density up-ramp. The subcycle pulse is coherently emitted by bubble-sheath electrons in REB-induced superluminal plasma wake. Using three-dimensional particle-in-cell and far-field time-domain radiation simulations as well as analytical modeling, we show that an isolated subcycle optical shock can be produced at the Cherenkov angle. This radiation has ultra-short attosecond-scale duration and high intensity and exhibits excellent directionality with ultra-low angular divergence and stable carrier envelope phase. Its central frequency can be easily tuned over a wide range, from the far-infrared to the ultra-violet, by adjusting the plasma and driver-beam density.
△ Less
Submitted 7 September, 2023; v1 submitted 12 January, 2023;
originally announced January 2023.
-
Hydrogen isotope separation using graphene-based membranes in liquid water
Authors:
Xiangrui Zhang,
Hequn Wang,
Tiantian Xiao,
Xiaoyi Chen,
Wen Li,
Yihan Xu,
Jianlong Lin,
Zhe Wang,
Hailin Peng,
Sheng Zhang
Abstract:
Hydrogen isotope separation has been effectively achieved using gaseous H2/D2 filtered through graphene/Nafion composite membranes. Nevertheless, deuteron nearly does not exist in the form of gaseous D2 in nature but in liquid water. Thus, it is a more feasible way to separate and enrich deuterium from water. Herein we have successfully transferred monolayer graphene to a rigid and porous polymer…
▽ More
Hydrogen isotope separation has been effectively achieved using gaseous H2/D2 filtered through graphene/Nafion composite membranes. Nevertheless, deuteron nearly does not exist in the form of gaseous D2 in nature but in liquid water. Thus, it is a more feasible way to separate and enrich deuterium from water. Herein we have successfully transferred monolayer graphene to a rigid and porous polymer substrate PITEM (polyimide tracked film), which could avoid the swelling problem of the Nafion substrate, as well as keep the integrity of graphene. Meanwhile, defects in large area of CVD graphene could be successfully repaired by interfacial polymerization resulting in high separation factor. Moreover, a new model was proposed for the proton transport mechanism through monolayer graphene based on the kinetic isotope effect (KIE). In this model, graphene plays the significant role in the H/D separation process by completely breaking the O-H/O-D bond, which can maximize the KIE leading to prompted H/D separation performance. This work suggests a promising application of using monolayer graphene in industry and proposes a pronounced understanding of proton transport in graphene
△ Less
Submitted 25 December, 2022;
originally announced December 2022.
-
Sensitivity analysis of biological washout and depth selection for a machine learning based dose verification framework in proton therapy
Authors:
Shixiong Yu,
Yuxiang Liu,
Zongsheng Hu,
Haozhao Zhang,
Pengyu Qi,
Hao Peng
Abstract:
Dose verification based on proton-induced positron emitters is a promising quality assurance tool and may leverage the strength of artificial intelligence. To move a step closer towards practical application, the sensitivity analysis of two factors needs to be performed: biological washout and depth selection. selection. A bi-directional recurrent neural network (RNN) model was developed. The trai…
▽ More
Dose verification based on proton-induced positron emitters is a promising quality assurance tool and may leverage the strength of artificial intelligence. To move a step closer towards practical application, the sensitivity analysis of two factors needs to be performed: biological washout and depth selection. selection. A bi-directional recurrent neural network (RNN) model was developed. The training dataset was generated based upon a CT image-based phantom (abdomen region) and multiple beam energies/pathways, using Monte-Carlo simulation (1 mm spatial resolution, no biological washout). For the modeling of biological washout, a simplified analytical model was applied to change raw activity profiles over a period of 5 minutes, incorporating both physical decay and biological washout. For the study of depth selection (a challenge linked to multi field/angle irradiation), truncations were applied at different window lengths (100, 125, 150 mm) to raw activity profiles. Finally, the performance of a worst-case scenario was examined by combining both factors (depth selection: 125 mm, biological washout: 5 mins). The accuracy was quantitatively evaluated in terms of range uncertainty, mean absolute error (MAE) and mean relative errors (MRE). Our proposed AI framework shows good immunity to the perturbation associated with two factors. The detection of proton-induced positron emitters, combined with machine learning, has great potential to implement online patient-specific verification in proton therapy.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
A Light Yield Enhancement Method Using Wavelength Shifter for the STCF EMC
Authors:
Zekun Jia,
Hanlin Yu,
Hongkun Mo,
Yong Song,
Zhongtao Shen,
Yunlong Zhang,
Jianbei Liu,
Haiping Peng
Abstract:
Super Tau-Charm Facility (STCF) is a next-generation high luminosity electron-positron collider facility and is currently one of the major options for accelerator-based particle physics experiment in China. The crystal-based electromagnetic calorimeter (EMC) with undoped CsI is a major sub-system of the STCF spectrometer. To fulfill the increasing physics requirements on measurement precision and…
▽ More
Super Tau-Charm Facility (STCF) is a next-generation high luminosity electron-positron collider facility and is currently one of the major options for accelerator-based particle physics experiment in China. The crystal-based electromagnetic calorimeter (EMC) with undoped CsI is a major sub-system of the STCF spectrometer. To fulfill the increasing physics requirements on measurement precision and the suffering of radiation, improving the detected light yield is an important task of STCF EMC R&D. This paper studies a "wavelength shifting in propagation" scheme for STCF EMC using the nanostructured organosilicon luminophore (NOL). The studies are performed by both Monte Carlo simulation and experimental tests. The light yield is proved to be improved by a factor of 1.59 in the experiment. Meanwhile, a study of the NOL's radiation hardness is carried out to verify the reliability of the NOL. No obvious degradation in the performance is observed with the total ionization does up to 100 krad, far beyond the total radiation dose of STCF with ten years of operation.
△ Less
Submitted 27 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Generation of subcycle isolated attosecond pulses by pumping ionizing gating
Authors:
Zhaohui Wu,
Hao Peng,
Xiaoming Zeng,
Zhaoli Li,
1 Zhimeng Zhang,
1 Huabao Cao,
Yuxi Fu,
Xiaodong Wang,
Xiao Wang,
Jie Mu,
1 Yanlei Zuo,
C. Riconda,
S. Weber,
Jingqin Su
Abstract:
We present a novel approach named as pumping ionizing gating (PIG) for the generation of isolated attosecond pulses (IAPs). In this regime, a short laser is used to ionize a pre-existing gas grating, creating a fast-extending plasma grating(FEPG) having an ionization front propagating with the velocity of light. A low-intensity long counterpropagating pump pulse is then reflected by a very narrow…
▽ More
We present a novel approach named as pumping ionizing gating (PIG) for the generation of isolated attosecond pulses (IAPs). In this regime, a short laser is used to ionize a pre-existing gas grating, creating a fast-extending plasma grating(FEPG) having an ionization front propagating with the velocity of light. A low-intensity long counterpropagating pump pulse is then reflected by a very narrow region of the ionization front, only where the Bragg conditions for resonant reflection is satisfied. Consequently, the pump reflection is confined within a sub-cycle region called PIG, and forms a wide-band coherent IAP in combination with the frequency up-conversion effect due to the plasma gradient. This approach results in a new scheme to generate IAPs fromlong picosecond pump pulses. Three-dimensional (3D) simulations show that a 1.6-ps, 1-μm pump pulse can be used to generate a 330 as laser pulse with a peak intensity approximately 33 times that of the pump and a conversion efficiency of around 0.1%.These results highlight the potential of the PIG method for generating IAPs with high conversion efficiency and peak intensity.
△ Less
Submitted 29 July, 2023; v1 submitted 13 December, 2022;
originally announced December 2022.
-
Recent Advancements of Artificial Intelligence in Particle Therapy
Authors:
Hao Peng,
Chao Wu,
Dan Nguyen,
Jan Schuemann,
Andrea Mairani,
Yuehu Pu,
Steve Jiang
Abstract:
We are in a golden age of progress in artificial intelligence (AI). Radiotherapy, due to its technology-intensive nature as well as direct human-machine interactions, is perfectly suited for benefitting from AI to enhance accuracy and efficiency. Over the past few years, a vast majority of AI research have already been published in the field of photon therapy, while the applications of AI specific…
▽ More
We are in a golden age of progress in artificial intelligence (AI). Radiotherapy, due to its technology-intensive nature as well as direct human-machine interactions, is perfectly suited for benefitting from AI to enhance accuracy and efficiency. Over the past few years, a vast majority of AI research have already been published in the field of photon therapy, while the applications of AI specifically targeted for particle therapy remain scarcely investigated. There are two distinct differences between photon therapy and particle therapy: beam interaction physics (photons vs. charged particles) and beam delivery mode (e.g. IMRT/VMAT vs. pencil beam scanning). As a result, different strategies of AI deployment are required between these two radiotherapy modalities. In this article, we aim to present a comprehensive survey of recent literatures exclusively focusing on AI-powered particle therapy. Six major aspects are included: treatment planning, dose calculation, range and dose verification, image guidance, quality assurance and adaptive replanning. A number of perspectives as well as potential challenges and common pitfalls, are also discussed.
△ Less
Submitted 18 November, 2022; v1 submitted 16 November, 2022;
originally announced November 2022.
-
Sub-kHz-linewidth external-cavity laser (ECL) with Si$_{3}$N$_{4}$ resonator used as a tunable pump for a Kerr frequency comb
Authors:
Pascal Maier,
Yung Chen,
Yilin Xu,
Yiyang Bao,
Matthias Blaicher,
Dimitri Geskus,
Ronald Dekker,
Junqiu Liu,
Philipp-Immanuel Dietrich,
Huanfa Peng,
Sebastian Randel,
Wolfgang Freude,
Tobias J. Kippenberg,
Christian Koos
Abstract:
Combining optical gain in direct-bandgap III-V materials with tunable optical feedback offered by advanced photonic integrated circuits is key to chip-scale external-cavity lasers (ECL), offering wideband tunability along with low optical linewidths. External feedback circuits can be efficiently implemented using low-loss silicon nitride (Si$_{3}$N$_{4}$) waveguides, which do not suffer from two-p…
▽ More
Combining optical gain in direct-bandgap III-V materials with tunable optical feedback offered by advanced photonic integrated circuits is key to chip-scale external-cavity lasers (ECL), offering wideband tunability along with low optical linewidths. External feedback circuits can be efficiently implemented using low-loss silicon nitride (Si$_{3}$N$_{4}$) waveguides, which do not suffer from two-photon absorption and can thus handle much higher power levels than conventional silicon photonics. However, co-integrating III-V-based gain elements with tunable external feedback circuits in chip-scale modules still represents a challenge, requiring either technologically demanding heterogeneous integration techniques or costly high-precision multi-chip assembly. In this work, we demonstrate Si$_{3}$N$_{4}$-based hybrid integrated ECL that exploit 3D-printed structures such as intra-cavity photonic wire bonds and facet-attached microlenses for low-loss optical coupling with relaxed alignment tolerances, thereby overcoming the need for active alignment while maintaining the full flexibility of multi-chip integration techniques. In a proof-of-concept experiment, we demonstrate an ECL offering a 90 nm tuning range (1480 nm - 1570 nm) with on-chip output powers above 12 dBm and side-mode suppression ratios of up to 59 dB. We achieve an intrinsic linewidth of 979 Hz, which is among the lowest values reported for comparable feedback architectures. The optical loss of the intra-cavity photonic wire bond between the III-V gain element and the Si$_{3}$N$_{4}$-based tunable feedback circuit amounts to approximately (1.6 $\pm$ 0.2) dB. We use the ECL as a tunable pump laser to generate a dissipative Kerr soliton frequency comb. To the best of our knowledge, our experiments represent the first demonstration of a single-soliton Kerr comb generated with a pump that is derived from a hybrid ECL.
△ Less
Submitted 10 February, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Beam Background Simulation and Experiment at BEPCII
Authors:
H. C . Shi,
B. Wang,
H. Y. Shi,
C. H. Yu,
M. Y. Dong,
H. P. Peng
Abstract:
A high-level beam background is a crucial challenge to future upgrades to the BEPCII collider. We report on the first separate measurement of the main beam background components at BEPCII. The separation measurement enables the beam background extrapolation towards the beam parameters assumed for the upgraded BEPCII. The measured rates of each background component are also compared with a brand-ne…
▽ More
A high-level beam background is a crucial challenge to future upgrades to the BEPCII collider. We report on the first separate measurement of the main beam background components at BEPCII. The separation measurement enables the beam background extrapolation towards the beam parameters assumed for the upgraded BEPCII. The measured rates of each background component are also compared with a brand-new simulation based on SAD and Geant4. The discrepancy between experiment and simulation remains 1$\sim$2 magnitudes after calibration with beam lifetime, which should be further investigated.
△ Less
Submitted 7 February, 2023; v1 submitted 21 October, 2022;
originally announced October 2022.
-
Bandwidth and Conversion-Efficiency Analysis of Kerr Soliton Combs in Dual-Pumped Resonators with Anomalous Dispersion
Authors:
Elias Gasmi,
Huanfa Peng,
Christian Koos,
Wolfgang Reichel
Abstract:
Kerr frequency combs generated in high-Q microresonators offer an immense potential in many applications, and predicting and quantifying their behavior, performance and stability is key to systematic device design. Based on an extension of the Lugiato-Lefever equation we investigate in this paper the perspectives of changing the pump scheme from the well-understood monochromatic pump to a dual-ton…
▽ More
Kerr frequency combs generated in high-Q microresonators offer an immense potential in many applications, and predicting and quantifying their behavior, performance and stability is key to systematic device design. Based on an extension of the Lugiato-Lefever equation we investigate in this paper the perspectives of changing the pump scheme from the well-understood monochromatic pump to a dual-tone configuration simultaneously pumping two modes. For the case of anomalous dispersion we give a detailed study of the optimal choices of detuning offsets and division of total pump power between the two modes in order to optimize single-soliton comb states with respect to performance metrics like power conversion efficiency and bandwidth. Our approach allows also to quantify the performance metrics of the optimal single-soliton comb states and determine their trends over a wide range of technically relevant parameters.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
In-orbit Radiation Damage Characterization of SiPMs in the GRID-02 CubeSat Detector
Authors:
Xutao Zheng,
Huaizhong Gao,
Jiaxing Wen,
Ming Zeng,
Xiaofan Pan,
Dacheng Xu,
Yihui Liu,
Yuchong Zhang,
Haowei Peng,
Yuchen Jiang,
Xiangyun Long,
Di'an Lu,
Dongxin Yang,
Hua Feng,
Zhi Zeng,
Jirong Cang,
Yang Tian,
GRID Collaboration
Abstract:
Recently, silicon photomultipliers (SiPMs) have been used in several space-borne missions, owing to their solid state, compact size, low operating voltage, and insensitivity to magnetic fields. However, operating SiPMs in space results in radiation damage and degraded performance. In-orbit quantitative studies on these effects are limited. In this study, we present in-orbit SiPM characterization r…
▽ More
Recently, silicon photomultipliers (SiPMs) have been used in several space-borne missions, owing to their solid state, compact size, low operating voltage, and insensitivity to magnetic fields. However, operating SiPMs in space results in radiation damage and degraded performance. In-orbit quantitative studies on these effects are limited. In this study, we present in-orbit SiPM characterization results obtained by the second detector of the Gamma-Ray Integrated Detectors (GRID-02), which was launched on 6 November 2020. An increase in dark current of $\sim$100 $μ$A/year per SiPM chip (model MicroFJ-60035-TSV) at 28.5 V and 5 $^{\circ}$C was observed. Consequently, the overall noise level (sigma) of the GRID-02 detector increased by $\sim$7.5 keV/year. The estimate of this increase is $\sim$40 $μ$A/year per SiPM chip at -20 $^{\circ}$C, highlighting the positive effect of using a cooling system.
△ Less
Submitted 11 October, 2022; v1 submitted 21 May, 2022;
originally announced May 2022.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
Design Automation of Photonic Resonator Weights
Authors:
Thomas Ferreira de Lima,
Eli A. Doris,
Simon Bilodeau,
Weipeng Zhang,
Aashu Jha,
Hsuan-Tung Peng,
Eric C. Blow,
Chaoran Huang,
Alexander N. Tait,
Bhavin J. Shastri,
Paul R. Prucnal
Abstract:
Neuromorphic photonic processors based on resonator weight banks are an emerging candidate technology for enabling modern artificial intelligence (AI) in high speed, analog systems. These purpose-built analog devices implement vector multiplications with the physics of resonator devices, offering efficiency, latency, and throughput advantages over equivalent electronic circuits. Along with these a…
▽ More
Neuromorphic photonic processors based on resonator weight banks are an emerging candidate technology for enabling modern artificial intelligence (AI) in high speed, analog systems. These purpose-built analog devices implement vector multiplications with the physics of resonator devices, offering efficiency, latency, and throughput advantages over equivalent electronic circuits. Along with these advantages, however, often comes the difficult challenges of compensation for fabrication variations and environmental disturbances. In this paper we review sources of variation and disturbances from our experiments, as well as mathematically define quantities that model them. Then, we introduce how the physics of resonators can be exploited to weight and sum multiwavelength signals. Finally, we outline automated design and control methodologies necessary to create practical, manufacturable, and high accuracy/precision resonator weight banks that can withstand operating conditions in the field. This represents a road map for unlocking the potential of resonator weight banks in practical deployment scenarios.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Nanophotonic cavity based synapse for scalable photonic neural networks
Authors:
Aashu Jha,
Chaoran Huang,
Thomas Ferriera deLima,
Hsuan-Tung Peng,
Bhavin Shastri,
Paul R. Prucnal
Abstract:
The bandwidth and energy demands of neural networks has spurred tremendous interest in developing novel neuromorphic hardware, including photonic integrated circuits. Although an optical waveguide can accommodate hundreds of channels with THz bandwidth, the channel count of photonic systems is always bottlenecked by the devices within. In WDM-based photonic neural networks, the synapses, i.e. netw…
▽ More
The bandwidth and energy demands of neural networks has spurred tremendous interest in developing novel neuromorphic hardware, including photonic integrated circuits. Although an optical waveguide can accommodate hundreds of channels with THz bandwidth, the channel count of photonic systems is always bottlenecked by the devices within. In WDM-based photonic neural networks, the synapses, i.e. network interconnections, are typically realized by microring resonators (MRRs), where the WDM channel count (N) is bounded by the free-spectral range of the MRRs. For typical Si MRRs, we estimate N <= 30 within the C-band. This not only restrains the aggregate throughput of the neural network but also makes applications with high input dimensions unfeasible. We experimentally demonstrate that photonic crystal nanobeam based synapses can be FSR-free within C-band, eliminating the bound on channel count. This increases data throughput as well as enables applications with high-dimensional inputs like natural language processing and high resolution image processing. In addition, the smaller physical footprint of photonic crystal nanobeam cavities offers higher tuning energy efficiency and a higher compute density than MRRs. Nanophotonic cavity based synapse thus offers a path towards realizing highly scalable photonic neural networks.
△ Less
Submitted 28 February, 2022;
originally announced March 2022.
-
Final results on the $0νββ$ decay half-life limit of $^{100}$Mo from the CUPID-Mo experiment
Authors:
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa,
J. Gascon,
L. Gironi,
A. Giuliani
, et al. (54 additional authors not shown)
Abstract:
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20…
▽ More
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20 mK. We present here the final analysis with the full exposure of CUPID-Mo ($^{100}$Mo exposure of 1.47 kg$\times$yr) used to search for lepton number violation via 0$νββ$ decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $^{100}$Mo 0$νββ$ decay half-life of $T^{0ν}_{1/2} > 1.8 \times 10^{24}$ year (stat.+syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $\left<m_{ββ}\right> < (0.28$--$0.49)$ eV, dependent upon the nuclear matrix element utilized.
△ Less
Submitted 11 December, 2022; v1 submitted 17 February, 2022;
originally announced February 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
Silicon photonic-electronic neural network for fibre nonlinearity compensation
Authors:
Chaoran Huang,
Shinsuke Fujisawa,
Thomas Ferreira de Lima,
Alexander N. Tait,
Eric C. Blow,
Yue Tian,
Simon Bilodeau,
Aashu Jha,
F atih Yaman,
Hsuan-Tung Peng,
Hussam G. Batshon,
Bhavin J. Shastri,
Yoshihisa Inada,
Ting Wang,
Paul R. Prucnal
Abstract:
In optical communication systems, fibre nonlinearity is the major obstacle in increasing the transmission capacity. Typically, digital signal processing techniques and hardware are used to deal with optical communication signals, but increasing speed and computational complexity create challenges for such approaches. Highly parallel, ultrafast neural networks using photonic devices have the potent…
▽ More
In optical communication systems, fibre nonlinearity is the major obstacle in increasing the transmission capacity. Typically, digital signal processing techniques and hardware are used to deal with optical communication signals, but increasing speed and computational complexity create challenges for such approaches. Highly parallel, ultrafast neural networks using photonic devices have the potential to ease the requirements placed on the digital signal processing circuits by processing the optical signals in the analogue domain. Here we report a silicon photonice-lectronic neural network for solving fibre nonlinearity compensation of submarine optical fibre transmission systems. Our approach uses a photonic neural network based on wavelength-division multiplexing built on a CMOS-compatible silicon photonic platform. We show that the platform can be used to compensate optical fibre nonlinearities and improve the signal quality (Q)-factor in a 10,080 km submarine fibre communication system. The Q-factor improvement is comparable to that of a software-based neural network implemented on a 32-bit graphic processing unit-assisted workstation. Our reconfigurable photonic-electronic integrated neural network promises to address pressing challenges in high-speed intelligent signal processing.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.
-
Dynamics of Cross-Platform Attention to Retracted Papers
Authors:
Hao Peng,
Daniel M. Romero,
Emőke-Ágnes Horvát
Abstract:
Retracted papers often circulate widely on social media, digital news and other websites before their official retraction. The spread of potentially inaccurate or misleading results from retracted papers can harm the scientific community and the public. Here we quantify the amount and type of attention 3,851 retracted papers received over time in different online platforms. Comparing to a set of n…
▽ More
Retracted papers often circulate widely on social media, digital news and other websites before their official retraction. The spread of potentially inaccurate or misleading results from retracted papers can harm the scientific community and the public. Here we quantify the amount and type of attention 3,851 retracted papers received over time in different online platforms. Comparing to a set of non-retracted control papers from the same journals, with similar publication year, number of co-authors and author impact, we show that retracted papers receive more attention after publication not only on social media, but also on heavily curated platforms, such as news outlets and knowledge repositories, amplifying the negative impact on the public. At the same time, we find that posts on Twitter tend to express more criticism about retracted than about control papers, suggesting that criticism-expressing tweets could contain factual information about problematic papers. Most importantly, around the time they are retracted, papers generate discussions that are primarily about the retraction incident rather than about research findings, showing that by this point papers have exhausted attention to their results and highlighting the limited effect of retractions. Our findings reveal the extent to which retracted papers are discussed on different online platforms and identify at scale audience criticism towards them. In this context, we show that retraction is not an effective tool to reduce online attention to problematic papers.
△ Less
Submitted 15 June, 2022; v1 submitted 14 October, 2021;
originally announced October 2021.
-
Photonic spiking neural networks and CMOS-compatible graphene-on-silicon spiking neurons
Authors:
Aashu Jha,
Chaoran Huang,
Hsuan-Tung Peng,
Bhavin Shastri,
Paul R. Prucnal
Abstract:
Spiking neural networks are known to be superior over artificial neural networks for their computational power efficiency and noise robustness. The benefits of spiking coupled with the high-bandwidth and low-latency of photonics can enable highly-efficient, noise-robust, high-speed neural processors. The landscape of photonic spiking neurons consists of an overwhelming majority of excitable lasers…
▽ More
Spiking neural networks are known to be superior over artificial neural networks for their computational power efficiency and noise robustness. The benefits of spiking coupled with the high-bandwidth and low-latency of photonics can enable highly-efficient, noise-robust, high-speed neural processors. The landscape of photonic spiking neurons consists of an overwhelming majority of excitable lasers and a few demonstrations on nonlinear optical cavities. The silicon platform is best poised to host a scalable photonic technology given its CMOS-compatibility and low optical loss. Here, we present a survey of existing photonic spiking neurons, and propose a novel spiking neuron based on a hybrid graphene-on-silicon microring cavity. A comparison among a representative sample of photonic spiking devices is also presented. Finally, we discuss methods employed in training spiking neural networks, their challenges as well as the application domain that can be enabled by photonic spiking neural hardware.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
A Photonics-based superheterodyne RF reception approach
Authors:
Guangyu Gao,
Qijun Liang,
Ziyu Liu,
Huanfa Peng,
Qiang Zhao,
Naijin Liu
Abstract:
A novel photonics-based RF reception approach is proposed as a competitive solution to meet the current challenges of photonic-based approaches and to realize high performances at the same time. The proposed approach adopts the superheterodyne configuration by a combination manner of electronic techniques and photonic techniques, including the ultrawideband generation of optical LO, the two-stage…
▽ More
A novel photonics-based RF reception approach is proposed as a competitive solution to meet the current challenges of photonic-based approaches and to realize high performances at the same time. The proposed approach adopts the superheterodyne configuration by a combination manner of electronic techniques and photonic techniques, including the ultrawideband generation of optical LO, the two-stage photonic superheterodyne frequency conversion and the real-time IF compensation. An engineering prototype has been developed and its performance has been evaluated in the laboratory environment. The experiment results preliminarily verify the feasibility of the proposed approach and its engineering potential. The typical performances are as follows: 0.1 GHz~ 45GHz operation spectrum range (>40 GHz), 900 MHz instantaneous bandwidth, 101 dBHz2/3 SFDR and 130 dBHz LDR, image rejections of ~80 dB for 1st frequency conversion and >90 dB for 2nd frequency conversion.
△ Less
Submitted 9 August, 2021;
originally announced August 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Effect of the selective localization of carbon nanotubes and phase domain in immiscible blends on tunable microwave dielectric properties
Authors:
Liping Zhou,
Yu Tian,
Peng Xu,
Huijie Wei,
Yuhan Li,
Hua-Xin Peng,
Faxiang Qin
Abstract:
In recent years, the immiscible polymer blend system has attracted much attention as the matrix of nanocomposites. Herein, from the perspective of dynamics, the control of the carbon nanotubes (CNTs) migration aided with the interface of polystyrene (PS) and poly(methyl methacrylate) (PMMA) blends was achieved through a facile melt mixing method. Thus, we revealed a comprehensive relationship betw…
▽ More
In recent years, the immiscible polymer blend system has attracted much attention as the matrix of nanocomposites. Herein, from the perspective of dynamics, the control of the carbon nanotubes (CNTs) migration aided with the interface of polystyrene (PS) and poly(methyl methacrylate) (PMMA) blends was achieved through a facile melt mixing method. Thus, we revealed a comprehensive relationship between several typical CNTs migrating scenarios and the microwave dielectric properties of their nanocomposites. Based on the unique morphologies and phase domain structures of the immiscible matrix, we further investigated the multiple microwave dielectric relaxation processes and shed new light on the relation between relaxation peak position and the phase domain size distribution. Moreover, by integrating the CNTs interface localization control with the matrix co-continuous structure construction, we found that the interface promotes double percolation effect to achieve conductive percolation at low CNTs loading (~1.06 vol%). Overall, the present study provides a unique nanocomposite material design symphonizing both functional fillers dispersion and location as well as the matrix architecture optimization for microwave applications.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Silicon microring synapses enable photonic deep learning beyond 9-bit precision
Authors:
Weipeng Zhang,
Chaoran Huang,
Hsuan-Tung Peng,
Simon Bilodeau,
Aashu Jha,
Eric Blow,
Thomas Ferreira De Lima,
Bhavin J. Shastri,
Paul Prucnal
Abstract:
Deep neural networks (DNN) consist of layers of neurons interconnected by synaptic weights. A high bit-precision in weights is generally required to guarantee high accuracy in many applications. Minimizing error accumulation between layers is also essential when building large-scale networks. Recent demonstrations of photonic neural networks are limited in bit-precision due to crosstalk and the hi…
▽ More
Deep neural networks (DNN) consist of layers of neurons interconnected by synaptic weights. A high bit-precision in weights is generally required to guarantee high accuracy in many applications. Minimizing error accumulation between layers is also essential when building large-scale networks. Recent demonstrations of photonic neural networks are limited in bit-precision due to crosstalk and the high sensitivity of optical components (e.g., resonators). Here, we experimentally demonstrate a record-high precision of 9 bits with a dithering control scheme for photonic synapses. We then numerically simulated the impact with increased synaptic precision on a wireless signal classification application. This work could help realize the potential of photonic neural networks for many practical, real-world tasks.
△ Less
Submitted 15 April, 2022; v1 submitted 14 March, 2021;
originally announced April 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Hot-Carrier Cooling in High-Quality Graphene is Intrinsically Limited by Optical Phonons
Authors:
Eva A. A. Pogna,
Xiaoyu Jia,
Alessandro Principi,
Alexander Block,
Luca Banszerus,
Jincan Zhang,
Xiaoting Liu,
Thibault Sohier,
Stiven Forti,
Karuppasamy Soundarapandian,
Bernat Terrés,
Jake D. Mehew,
Chiara Trovatello,
Camilla Coletti,
Frank H. L. Koppens,
Mischa Bonn,
Niek van Hulst,
Matthieu J. Verstraete,
Hailin Peng,
Zhongfan Liu,
Christoph Stampfer,
Giulio Cerullo,
Klaas-Jan Tielrooij
Abstract:
Many promising optoelectronic devices, such as broadband photodetectors, nonlinear frequency converters, and building blocks for data communication systems, exploit photoexcited charge carriers in graphene. For these systems, it is essential to understand, and eventually control, the cooling dynamics of the photoinduced hot-carrier distribution. There is, however, still an active debate on the dif…
▽ More
Many promising optoelectronic devices, such as broadband photodetectors, nonlinear frequency converters, and building blocks for data communication systems, exploit photoexcited charge carriers in graphene. For these systems, it is essential to understand, and eventually control, the cooling dynamics of the photoinduced hot-carrier distribution. There is, however, still an active debate on the different mechanisms that contribute to hot-carrier cooling. In particular, the intrinsic cooling mechanism that ultimately limits the cooling dynamics remains an open question. Here, we address this question by studying two technologically relevant systems, consisting of high-quality graphene with a mobility >10,000 cm$^2$V$^{-1}$s$^{-1}$ and environments that do not efficiently take up electronic heat from graphene: WSe$_2$-encapsulated graphene and suspended graphene. We study the cooling dynamics of these two high-quality graphene systems using ultrafast pump-probe spectroscopy at room temperature. Cooling via disorder-assisted acoustic phonon scattering and out-of-plane heat transfer to the environment is relatively inefficient in these systems, predicting a cooling time of tens of picoseconds. However, we observe much faster cooling, on a timescale of a few picoseconds. We attribute this to an intrinsic cooling mechanism, where carriers in the hot-carrier distribution with enough kinetic energy emit optical phonons. During phonon emission, the electronic system continuously re-thermalizes, re-creating carriers with enough energy to emit optical phonons. We develop an analytical model that explains the observed dynamics, where cooling is eventually limited by optical-to-acoustic phonon coupling. These fundamental insights into the intrinsic cooling mechanism of hot carriers in graphene will play a key role in guiding the development of graphene-based optoelectronic devices.
△ Less
Submitted 5 March, 2021;
originally announced March 2021.
-
A Laser Spiking Neuron in a Photonic Integrated Circuit
Authors:
Mitchell A. Nahmias,
Hsuan-Tung Peng,
Thomas Ferreira de Lima,
Chaoran Huang,
Alexander N. Tait,
Bhavin J. Shastri,
Paul R. Prucnal
Abstract:
There has been a recent surge of interest in the implementation of linear operations such as matrix multipications using photonic integrated circuit technology. However, these approaches require an efficient and flexible way to perform nonlinear operations in the photonic domain. We have fabricated an optoelectronic nonlinear device--a laser neuron--that uses excitable laser dynamics to achieve bi…
▽ More
There has been a recent surge of interest in the implementation of linear operations such as matrix multipications using photonic integrated circuit technology. However, these approaches require an efficient and flexible way to perform nonlinear operations in the photonic domain. We have fabricated an optoelectronic nonlinear device--a laser neuron--that uses excitable laser dynamics to achieve biologically-inspired spiking behavior. We demonstrate functionality with simultaneous excitation, inhibition, and summation across multiple wavelengths. We also demonstrate cascadability and compatibility with a wavelength multiplexing protocol, both essential for larger scale system integration. Laser neurons represent an important class of optoelectronic nonlinear processors that can complement both the enormous bandwidth density and energy efficiency of photonic computing operations.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.