Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors
Authors:
J. Xie,
C. Peng,
S. Joosten,
Z. -E. Meziani,
A. Camsonne,
M. Jones,
S. Malace,
E. Kaczanowicz,
M. Rehfuss,
N. Sparveris,
M. Paolone,
M. Foley,
M. Minot,
M. Popecki,
Z. W. Zhao
Abstract:
The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Ph…
▽ More
The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD$^{\rm TM}$) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab).
The results of this test confirmed that the coarse-pixelated (2.5$\times$2.5 cm$^2$ pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.
△ Less
Submitted 3 July, 2024; v1 submitted 1 February, 2024;
originally announced February 2024.
-
The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV
Authors:
John Arrington,
Jay Benesch,
Alexandre Camsonne,
Jimmy Caylor,
Jian-Ping Chen,
Silviu Covrig Dusa,
Alexander Emmert,
George Evans,
Haiyan Gao,
J. Ole Hansen,
Garth M. Huber,
Sylvester Joosten,
Vladimir Khachatryan,
Nilanga Liyanage,
Zein-Eddine Meziani,
Michael Nycz,
Chao Peng,
Michael Paolone,
Whit Seay,
Paul A. Souder,
Nikos Sparveris,
Hubert Spiesberger,
Ye Tian,
Eric Voutier,
Junqi Xie
, et al. (6 additional authors not shown)
Abstract:
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit…
▽ More
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3-D momentum space from Semi-Inclusive Deep Inelastic Scattering (SIDIS), expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS (PVDIS), a precision measurement of $J/ψ$ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.
△ Less
Submitted 12 February, 2023; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Performance of photosensors in a high-rate environment for gas Cherenkov detectors
Authors:
Chao Peng,
Junqi Xie,
Sylvester Joosten,
Zein-Eddine Meziani,
Alexandre Camsonne,
Mark Jones,
Edward Kaczanowicz,
Melanie Rehfuss,
Nikolaos Sparveris,
Michael Paolone,
Michael Foley,
Michael Minot,
Mark Popecki
Abstract:
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the…
▽ More
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small telescopic Cherenkov device in a high-rate environment up to 60 kHz/cm$^2$, in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the experimental performance of our telescopic device.
△ Less
Submitted 3 May, 2022; v1 submitted 23 November, 2020;
originally announced November 2020.