-
Reconciling mean-squared radius differences in the silver chain through improved measurement and {\it ab initio} calculations
Authors:
B. Ohayon,
J. E. Padilla-Castillo,
S. C. Wright,
G. Meijer,
B. K. Sahoo
Abstract:
Nuclear charge radius differences in the silver isotopic chain have been reported through different combinations of experiment and theory, exhibiting a tension of two combined standard errors. This study investigates this issue by combining high-accuracy calculations for six low-lying states of atomic silver with an improved measurement of the $5s ^2S_{1/2} - 5p ^2P_{3/2}$ transition optical isoto…
▽ More
Nuclear charge radius differences in the silver isotopic chain have been reported through different combinations of experiment and theory, exhibiting a tension of two combined standard errors. This study investigates this issue by combining high-accuracy calculations for six low-lying states of atomic silver with an improved measurement of the $5s ^2S_{1/2} - 5p ^2P_{3/2}$ transition optical isotope shift. Our calculations predict measured electronic transition energies in Ag I at the 0.3\% level, the highest accuracy achieved in this system so far. We calculate electronic isotope shift factors by employing analytical response relativistic coupled-cluster theory, and find that a consistent charge radius difference between $^{107,109}$Ag is returned when combining our calculations with the available optical isotope shift measurements. We therefore recommend an improved value for the mean-squared charge radius difference between $^{107}$Ag and $^{109}$Ag as $0.207(3)[4]$ fm$^2$, within one combined error from the value derived from muonic Ag experiments, and an updated set of charge radii differences across the isotopic chain.
△ Less
Submitted 5 July, 2024; v1 submitted 12 February, 2024;
originally announced February 2024.
-
MMC Array to Study X-ray Transitions in Muonic Atoms
Authors:
Daniel Unger,
Andreas Abeln,
Thomas Elias Cocolios,
Ofir Eizenberg,
Christian Enss,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Paul Indelicato,
Ashish Jadhav,
Daniel Kreuzberger,
Klaus Kirch,
Andreas Knecht,
Jorge Machado,
Ben Ohayon,
Nancy Paul,
Randolf Pohl,
Katharina von Schoeler,
Stergiani Marina Vogiatzi,
Frederik Wauters
Abstract:
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We di…
▽ More
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.
△ Less
Submitted 6 April, 2024; v1 submitted 20 November, 2023;
originally announced November 2023.
-
Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
Authors:
Ben Ohayon,
Andreas Abeln,
Silvia Bara,
Thomas Elias Cocolios,
Ofir Eizenberg,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Guillaume Hupin,
Paul Indelicato,
Klaus Kirch,
Andreas Knecht,
Daniel Kreuzberger,
Jorge Machado,
Petr Navratil,
Nancy Paul,
Randolf Pohl,
Daniel Unger,
Stella Vogiatzi,
Katharina von Schoeler,
Frederik Wauters
Abstract:
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyon…
▽ More
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
△ Less
Submitted 17 February, 2024; v1 submitted 5 October, 2023;
originally announced October 2023.
-
Hyperfine structure and isotope shifts of the $^1P_1 \leftarrow{} ^{1}S_0$ transition in atomic zinc
Authors:
David Röser,
J. Eduardo Padilla-Castillo,
Ben Ohayon,
Russell Thomas,
Stefan Truppe,
Gerard Meijer,
Simon Stellmer,
Sid C. Wright
Abstract:
We report absolute frequency, isotope shift, radiative lifetime and hyperfine structure measurements of the $^1P_1 \leftarrow{} ^{1}S_0$ (213.8 nm) transition in Zn I using a cryogenic buffer gas beam. Laser-induced fluorescence is collected with two orthogonally oriented detectors to take advantage of differences in the emission pattern of the isotopes. This enables clear distinction between isot…
▽ More
We report absolute frequency, isotope shift, radiative lifetime and hyperfine structure measurements of the $^1P_1 \leftarrow{} ^{1}S_0$ (213.8 nm) transition in Zn I using a cryogenic buffer gas beam. Laser-induced fluorescence is collected with two orthogonally oriented detectors to take advantage of differences in the emission pattern of the isotopes. This enables clear distinction between isotopes whose resonances are otherwise unresolved, and a measurement of the fermion hyperfine structure parameters, $A(^{67}$Zn)$=20(2)$ MHz and $B(^{67}$Zn)$=10(5)$ MHz. We reference our frequency measurements to an ultralow expansion cavity and achieve an uncertainty at the level of 1 MHz, about 1 percent of the natural linewidth of the transition.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
All-optical Differential Radii in Zinc
Authors:
B. K. Sahoo,
B. Ohayon
Abstract:
We conduct high-accuracy calculations of isotope shift (IS) factors of the states involving the $D_1$ and $D_2$ lines in Zn II. Together with a global fit to the available optical IS data, we extract nuclear-model-independent, precise differential radii for a long chain of Zn isotopes. These radii are compared with the ones inferred from muonic X-ray measurements. Some deviations are found, which…
▽ More
We conduct high-accuracy calculations of isotope shift (IS) factors of the states involving the $D_1$ and $D_2$ lines in Zn II. Together with a global fit to the available optical IS data, we extract nuclear-model-independent, precise differential radii for a long chain of Zn isotopes. These radii are compared with the ones inferred from muonic X-ray measurements. Some deviations are found, which we ascribe to the deformed nature of Zn nuclei that introduces nuclear-model dependency into radii extractions from muonic atoms. We arrive at the conclusion that in cases where the many-body atomic calculations of IS factors are well-established, optical determinations of differential radii are more reliable than those extracted from the muonic X-ray measurements, opening the door to improved determination of nuclear radii across the nuclear chart.
△ Less
Submitted 18 July, 2023;
originally announced July 2023.
-
Production of antihydrogen atoms by 6 keV antiprotons through a positronium cloud
Authors:
P. Adrich,
P. Blumer,
G. Caratsch,
M. Chung,
P. Cladé,
P. Comini,
P. Crivelli,
O. Dalkarov,
P. Debu,
A. Douillet,
D. Drapier,
P. Froelich,
N. Garroum,
S. Guellati-Khelifa,
J. Guyomard,
P-A. Hervieux,
L. Hilico,
P. Indelicato,
S. Jonsell,
J-P. Karr,
B. Kim,
S. Kim,
E-S. Kim,
Y. J. Ko,
T. Kosinski
, et al. (39 additional authors not shown)
Abstract:
We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen productio…
▽ More
We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen production with a significance of 3-4 standard deviations.
△ Less
Submitted 3 July, 2023; v1 submitted 27 June, 2023;
originally announced June 2023.
-
Pulsed CW laser for long-term spectroscopic measurements at high power in deep-UV
Authors:
Nikita Zhadnov,
Artem Golovizin,
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Paolo Crivelli
Abstract:
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while keeping t…
▽ More
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while keeping the average power low to prevent mirror degradation. Additionally, this method significantly decreases laser-induced background on charged particle detectors. The described 244 nm laser system is designed for 1S-2S two-photon CW spectroscopy of muonium in the Mu-MASS project. It was tested to provide intracavity powers above 20 W, requiring maintenance only a few times a day. The pulsing technique demonstrates minimal impact on the radiation frequency, with no observed shifts exceeding 15 kHz. Our approach represents a promising new technique for high-precision spectroscopy of atoms in harsh UV environments and demonstrates the feasibility of CW spectroscopy of muonium.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Update of Muonium 1S-2S transition frequency
Authors:
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Artem Golovizin,
Nikita Zhadnov,
Paolo Crivelli
Abstract:
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electr…
▽ More
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electron-to-muon mass ratio or, combined with the Muonium hyperfine splitting, an independent value of the Rydberg constant. Furthermore we report on the current status of the Mu-MASS experiment, which aims at measuring the Muonium 1S-2S transition frequency at a 10 kHz uncertainty level.
△ Less
Submitted 17 March, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
Muonic-Atom Spectroscopy and Impact on Nuclear Structure and Precision QED Theory
Authors:
Aldo Antognini,
Sonia Bacca,
Andreas Fleischmann,
Loredana Gastaldo,
Franziska Hagelstein,
Paul Indelicato,
Andreas Knecht,
Vadim Lensky,
Ben Ohayon,
Vladimir Pascalutsa,
Nancy Paul,
Randolf Pohl,
Frederik Wauters
Abstract:
Recent progress in laser and x-ray spectroscopy of muonic atoms offers promising long-term possibilities at the intersection of atomic, nuclear and particle physics. In muonic hydrogen, laser spectroscopy measurements will determine the ground-state hyperfine splitting (HFS) and additionally improve the Lamb shift by a factor of 5. Precision spectroscopy with cryogenic microcalorimeters has the po…
▽ More
Recent progress in laser and x-ray spectroscopy of muonic atoms offers promising long-term possibilities at the intersection of atomic, nuclear and particle physics. In muonic hydrogen, laser spectroscopy measurements will determine the ground-state hyperfine splitting (HFS) and additionally improve the Lamb shift by a factor of 5. Precision spectroscopy with cryogenic microcalorimeters has the potential to significantly improve the charge radii of the light nuclei in the $Z=3-8$ range. Complementary progress in precision should be achieved on the theory of nucleon- and nuclear-structure effects. The impact of this muonic-atom spectroscopy program will be amplified by the upcoming results from H and He$^+$ spectroscopy, simple molecules such as HD$^+$ and Penning trap measurements. In this broader context, one can test ab-initio nuclear theories, bound-state QED for two- or three-body systems, and determine fundamental constants, such as the Rydberg ($R_\infty$) and the fine-structure ($α$) constants.
△ Less
Submitted 30 October, 2022;
originally announced October 2022.
-
High-resolution isotope-shift spectroscopy of Cd I
Authors:
Simon Hofsäss,
J. Eduardo Padilla-Castillo,
Sid C. Wright,
Sebastian Kray,
Russell Thomas,
Boris G. Sartakov,
Ben Ohayon,
Gerard Meijer,
Stefan Truppe
Abstract:
We present absolute frequency measurements of the ${}^{1}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ ($229$nm) and ${}^{3}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ ($326$nm) transitions for all naturally occurring isotopes of cadmium. The isotope shifts and hyperfine intervals of the fermionic isotopes are determined with an accuracy of 3.3MHz. We find that quantum interference in the laser-induced fluo…
▽ More
We present absolute frequency measurements of the ${}^{1}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ ($229$nm) and ${}^{3}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ ($326$nm) transitions for all naturally occurring isotopes of cadmium. The isotope shifts and hyperfine intervals of the fermionic isotopes are determined with an accuracy of 3.3MHz. We find that quantum interference in the laser-induced fluorescence spectra of the ${}^{1}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ transition causes an error of up to 29(5)MHz in determining the hyperfine splitting, when not accounted for with an appropriate model. Using a King-plot analysis, we extract the field- and mass-shift parameters and determine nuclear charge radius differences for the fermions. The lifetime of the $^1\text{P}_1$ state is determined to be 1.60(5)ns by measuring the natural linewidth of the ${}^{1}\text{P}_1 \leftarrow {}^{1}\text{S}_0$ transition. These results resolve significant discrepancies among previous measurements.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.
-
Isotope Shifts in Cadmium as a Sensitive Probe for Physics Beyond the Standard Model
Authors:
B. Ohayon,
S. Hofsäss,
J. E. Padilla-Castillo,
S. C. Wright,
G. Meijer,
S. Truppe,
K. Gibble,
B. K. Sahoo
Abstract:
Isotope shifts (ISs) in atomic energy levels are sensitive probes of nuclear structure and new physics beyond the Standard Model. We present an analysis of the ISs of the cadmium atom (Cd I) and singly charged cadmium ion (Cd II). ISs of the 229 nm, 326 nm, 361 nm and 480 nm lines of Cd I are measured with a variety of techniques; buffer-gas-cooled beam spectroscopy, capturing atoms in a magneto-o…
▽ More
Isotope shifts (ISs) in atomic energy levels are sensitive probes of nuclear structure and new physics beyond the Standard Model. We present an analysis of the ISs of the cadmium atom (Cd I) and singly charged cadmium ion (Cd II). ISs of the 229 nm, 326 nm, 361 nm and 480 nm lines of Cd I are measured with a variety of techniques; buffer-gas-cooled beam spectroscopy, capturing atoms in a magneto-optic-trap, and optical pumping. IS constants for the D1 and D2 lines of Cd II are calculated with high accuracy by employing analytical response relativistic coupled-cluster theory in the singles, doubles and triples approximations. Combining the calculations for Cd II with experiments, we infer IS constants for all low-lying transitions in Cd I. We benchmark these constants as calculated via different many-body methods. Our calculations for Cd II enable nuclear charge radii of Cd isotopes to be extracted with unprecedented accuracy. The combination of our precise calculations and measurements shows that King Plots for Cd I can improve the state-of-theart sensitivity to a new heavy boson by up to two orders of magnitude.
△ Less
Submitted 29 August, 2022;
originally announced August 2022.
-
Measurement of the $2S_{1/2},F$=$0 \rightarrow 2P_{1/2},F$=$1$ transition in Muonium
Authors:
G. Janka,
B. Ohayon,
I. Cortinovis,
Z. Burkley,
L. de Sousa Borges,
E. Depero,
A. Golovizin,
X. Ni,
Z. Salman,
A. Suter,
T. Prokscha,
P. Crivelli
Abstract:
Muons are puzzling physicists since their discovery when they were first thought to be the meson predicted by Yukawa to mediate the strong force. The recent results at Fermilab on the muon g-2 anomaly puts the muonic sector once more under the spotlight and calls for new measurements with this fascinating particle. Here we present the results of the first measurement of the $2S_{1/2},F$=…
▽ More
Muons are puzzling physicists since their discovery when they were first thought to be the meson predicted by Yukawa to mediate the strong force. The recent results at Fermilab on the muon g-2 anomaly puts the muonic sector once more under the spotlight and calls for new measurements with this fascinating particle. Here we present the results of the first measurement of the $2S_{1/2},F$=$0 \rightarrow 2P_{1/2},F$=$1$ transition in Muonium, the hydrogen-like bound state of a positive muon and an electron. The measured value of 580.6 $\pm$6.8 MHz is in agreement with the theoretical calculations. From this measurement a value of the Lamb shift of 1045.5 $\pm$6.8 MHz is extracted, compatible with previous experiments. We also determine for the first time the $2S$ hyperfine splitting in Muonium to be 559.6$\pm$7.2 MHz. The measured transition being isolated from the other hyperfine levels holds the promise to provide an improved determination of the Muonium Lamb shift at a level where bound state QED recoil corrections not accessible in hydrogen could be tested. Such a measurement will also be sensitive to new physics in the muonic sector, e.g. to new bosons which might provide an explanation of the g-2 muon anomaly or Lorentz and CPT violation. We also present the first observation of Muonium in the $n = 3$ excited state opening up the possibility of new precise microwave measurements as realized in hydrogen.
△ Less
Submitted 12 May, 2022;
originally announced May 2022.
-
Positron accumulation in the GBAR experiment
Authors:
P. Blumer,
M. Charlton,
M. Chung,
P. Clade,
P. Comini,
P. Crivelli,
O. Dalkarov,
P. Debu,
L. Dodd,
A. Douillet,
S. Guellati,
P. -A Hervieux,
L. Hilico,
P. Indelicato,
G. Janka,
S. Jonsell,
J. -P. Karr,
B. H. Kim,
E. S. Kim,
S. K. Kim,
Y. Ko,
T. Kosinski,
N. Kuroda,
B. M. Latacz,
B. Lee
, et al. (45 additional authors not shown)
Abstract:
We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), whic…
▽ More
We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), which has been cooled to a low temperature, and observing the subsequent H annihilation following free fall. To produce one H+ ion, about 10^10 positrons, efficiently converted into positronium (Ps), together with about 10^7 antiprotons (p), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) x 10^9 positrons in 1100 seconds.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
Muonium Lamb shift: theory update and experimental prospects
Authors:
Gianluca Janka,
Ben Ohayon,
Paolo Crivelli
Abstract:
We review the theory of the Lamb shift for muonium, provide an updated numerical value and present the prospects of the Mu-MASS collaboration at PSI to improve upon their recent measurement. Due to its smaller nuclear mass, the contributions of the higher-order recoil corrections (160kHz level) and nucleus self-energy 40kHz level) are enhanced for muonium compared to hydrogen where those are below…
▽ More
We review the theory of the Lamb shift for muonium, provide an updated numerical value and present the prospects of the Mu-MASS collaboration at PSI to improve upon their recent measurement. Due to its smaller nuclear mass, the contributions of the higher-order recoil corrections (160kHz level) and nucleus self-energy 40kHz level) are enhanced for muonium compared to hydrogen where those are below the level of the latest measurement performed by Hessels et al. and thus could not be tested yet. The ongoing upgrades to the Mu-MASS setup will open up the possibility to probe these contributions and improve the sensitivity of this measurement to searches for new physics in the muonic sector.
△ Less
Submitted 27 November, 2021;
originally announced November 2021.
-
Nuclear charge radii of Na isotopes: A tale of two theories
Authors:
B. Ohayon,
R. F. Garcia Ruiz,
Z. H. Sun,
G. Hagen,
T. Papenbrock,
B. K. Sahoo
Abstract:
The accuracy of atomic theory calculations limits the extraction of nuclear charge radii from isotope shift measurements of odd-proton nuclei. For Na isotopes, though precise spectroscopic measurements have existed since more than half a century, calculations by different methods offer a wide range of values. Here, we present accurate atomic calculations to reliably extract the Na charge radii. By…
▽ More
The accuracy of atomic theory calculations limits the extraction of nuclear charge radii from isotope shift measurements of odd-proton nuclei. For Na isotopes, though precise spectroscopic measurements have existed since more than half a century, calculations by different methods offer a wide range of values. Here, we present accurate atomic calculations to reliably extract the Na charge radii. By combining experimental matter radii with nuclear coupled-cluster calculations based on nucleon-nucleon and three-nucleon forces, we constrain the parameters obtained from the atomic calculations. Therefore, this study guides atomic theory and highlights the importance of using accurate atomic and nuclear computations in our understanding of the size of light nuclei.
△ Less
Submitted 22 September, 2021;
originally announced September 2021.
-
Precision measurement of the Lamb shift in Muonium
Authors:
B. Ohayon,
G. Janka,
I. Cortinovis,
Z. Burkley,
L. de Sousa Bourges,
E. Depero,
A. Golovizin,
X. Ni,
Z. Salman,
A. Suter,
C. Vigo,
T. Prokscha,
P. Crivelli
Abstract:
We report a new measurement of the $n=2$ Lamb shift in Muonium using microwave spectroscopy. Our result of $1047.2(2.3)_\textrm{stat}(1.1)_\textrm{syst}$ MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within one standard deviation allowing us to set limits on CPT violation in the muonic sector, as well as on new ph…
▽ More
We report a new measurement of the $n=2$ Lamb shift in Muonium using microwave spectroscopy. Our result of $1047.2(2.3)_\textrm{stat}(1.1)_\textrm{syst}$ MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within one standard deviation allowing us to set limits on CPT violation in the muonic sector, as well as on new physics coupled to muons and electrons which could provide an explanation of the muon $g-2$ anomaly.
△ Less
Submitted 30 September, 2021; v1 submitted 29 August, 2021;
originally announced August 2021.
-
Towards an independent determination of muon g-2 from muonium spectroscopy
Authors:
Cédric Delaunay,
Ben Ohayon,
Yotam Soreq
Abstract:
We show that muonium spectroscopy in the coming years can reach a precision high enough to determine the anomalous magnetic moment of the muon below one part per million (ppm). Such an independent determination of muon g-2, which is not limited by hadronic uncertainties, would certainly shed light on the 2ppm difference currently observed between spin-precession measurements and (R-ratio based) St…
▽ More
We show that muonium spectroscopy in the coming years can reach a precision high enough to determine the anomalous magnetic moment of the muon below one part per million (ppm). Such an independent determination of muon g-2, which is not limited by hadronic uncertainties, would certainly shed light on the 2ppm difference currently observed between spin-precession measurements and (R-ratio based) Standard Model predictions. The magnetic dipole interaction between electrons and (anti)muons bound in muonium gives rise to a hyperfine splitting (HFS) of the ground state which is sensitive to the muon anomalous magnetic moment. A direct comparison of the muonium frequency measurements of the HFS at J-PARC and the 1S-2S transition at PSI with theory predictions will allow to extract muon g-2 with high precision. Improving the accuracy of QED calculations of these transitions by about one order of magnitude is also required. Moreover, the good agreement between theory and experiment for the electron g-2 indicates that new physics interactions are unlikely to affect muonium spectroscopy down to the envisaged precision.
△ Less
Submitted 17 January, 2022; v1 submitted 22 June, 2021;
originally announced June 2021.
-
Stable High Power deep-UV Enhancement Cavity in Ultra High Vacuum with Fluoride Coatings
Authors:
Zakary Burkley,
Lucas de Sousa Borges,
Ben Ohayon,
Artem Golovozin,
Jesse Zhang,
Paolo Crivelli
Abstract:
We demonstrate the superior performance of fluoride coated versus oxide coated mirrors in long term vacuum operation of a high power deep-ultraviolet enhancement cavity. In high vacuum ($10^{-8}$ mbar), the fluoride optics can maintain up to a record-high 10 w of stable intracavity power on one hour time scales, whereas for the oxide optics, we observe rapid degradation at lower intracavity powers…
▽ More
We demonstrate the superior performance of fluoride coated versus oxide coated mirrors in long term vacuum operation of a high power deep-ultraviolet enhancement cavity. In high vacuum ($10^{-8}$ mbar), the fluoride optics can maintain up to a record-high 10 w of stable intracavity power on one hour time scales, whereas for the oxide optics, we observe rapid degradation at lower intracavity powers with a rate that increases with power. After observing degradation in high vacuum, we can recover the fluoride and oxide optics with oxygen; however, this recovery process becomes ineffective after several applications. For fluoride coatings, we see that initial UV conditioning in an oxygen environment helps to improve the performances of the optics. In oxygen-rich environments from $\sim 10^{-4}$ mbar to 1 mbar, the fluoride optics can stably maintain up to 20 W of intracavity power on several-hour time scales whereas for the oxide optics there is immediate degradation with a rate that increases with decreasing oxygen pressure.
△ Less
Submitted 31 May, 2021;
originally announced May 2021.
-
Benchmarking Many-body Approaches for the Determination of Isotope Shift Constants: Application to the Li, Be$^+$ and Ar$^{15+}$ Isoelectronic Systems
Authors:
B. K. Sahoo,
B. Ohayon
Abstract:
We have applied relativistic coupled-cluster (RCC) theory to determine the isotope shift (IS) constants of the first eight low-lying states of the Li, Be$^+$ and Ar$^{15+}$ isoelectronic systems. Though the RCC theory with singles, doubles and triples approximation (RCCSDT method) is an exact method for these systems for a given set of basis functions, we notice large differences in the results fr…
▽ More
We have applied relativistic coupled-cluster (RCC) theory to determine the isotope shift (IS) constants of the first eight low-lying states of the Li, Be$^+$ and Ar$^{15+}$ isoelectronic systems. Though the RCC theory with singles, doubles and triples approximation (RCCSDT method) is an exact method for these systems for a given set of basis functions, we notice large differences in the results from this method when various procedures in the RCC theory framework are adopted to estimate the IS constants. This has been demonstrated by presenting the IS constants of the aforementioned states from the finite-field, expectation value and analytical response (AR) approaches of the RCCSDT method. Contributions from valence triple excitations, Breit interaction and lower-order QED effects to the evaluation of these IS constants are also highlighted. Our results are compared with high-precision calculations reported using few-body methods wherever possible. We find that results from the AR procedure are more reliable than the other two approaches. This analysis is crucial for understanding the roles of electron correlation effects in the accurate determination of IS constants in the heavier atomic systems, where few-body methods cannot be applied.
△ Less
Submitted 27 May, 2021;
originally announced May 2021.
-
$^{23}$Ne Production at SARAF-I
Authors:
Yonatan Mishnayot,
Hitesh Rahangdale,
Ben Ohayon,
Sergey Vaintraub,
Tsviki Hirsh,
Leo Weismann,
Amichay Perry,
Asher Shor,
Arik Kreisel,
Shadi Ya'akobi,
Einat Buznach,
Guy Ron
Abstract:
In this article, we present a measurement of flow rate, yield and effusion time of a $^{23}$Ne production and transport system. We used an accelerator-driven Li(d,n) neutron source to produce neutrons up to 20 MeV. The radioactive atoms were produced by a $^{23}$Na(n,p) reaction at a NaCl target. Later, the atoms were diffused out from the NaCl crystals and effused from the production chamber via…
▽ More
In this article, we present a measurement of flow rate, yield and effusion time of a $^{23}$Ne production and transport system. We used an accelerator-driven Li(d,n) neutron source to produce neutrons up to 20 MeV. The radioactive atoms were produced by a $^{23}$Na(n,p) reaction at a NaCl target. Later, the atoms were diffused out from the NaCl crystals and effused from the production chamber via a 10 m hose to a measurement cell and their decay products were detected using high purity germanium (HPGe) and plastic scintillator detectors. The resulting flow rate was $6.9\pm0.5\cdot 10^4\sfrac{atoms}{sec}$ and the total yield was $3.2\pm0.4\cdot10^{-9}\sfrac{atoms}{deuteron}$. We summarize our methods and estimates of efficiencies, rates of production and effusion.
△ Less
Submitted 31 May, 2020;
originally announced June 2020.
-
Intense beam of metastable Muonium
Authors:
G. Janka,
B. Ohayon,
Z. Burkley,
L. Gerchow,
N. Kuroda,
X. Ni,
R. Nishi,
Z. Salman,
A. Suter,
M. Tuzi,
C. Vigo,
T. Prokscha,
P. Crivelli
Abstract:
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility.…
▽ More
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility. Such a source of abundant low energy $\mathrm{μ^+}$ has only become available in recent years, e.g. at the Low-Energy Muon beamline at the Paul Scherrer Institute. Using this source, we report on the successful creation of an intense, directed beam of metastable Muonium. We find that even though the theoretical Muonium fraction is maximal in the low energy range of $2-5$ keV, scattering by the foil and transport characteristics of the beamline favor slightly higher $\mathrm{μ^+}$ energies of $7-10$ keV. We estimate that an event detection rate of a few events per second for a future Lamb shift measurement is feasible, enabling an increase in precision by two orders of magnitude over previous determinations.
△ Less
Submitted 6 May, 2020; v1 submitted 5 April, 2020;
originally announced April 2020.
-
A decay microscope for trapped neon isotopes
Authors:
Ben Ohayon,
Hitesh Rahangdale,
Elad Parnes,
Gedalia Perelman,
Oded Heber,
Guy Ron
Abstract:
We review the design, simulation, and tests, of a detection system for measuring the energy distribution of daughter nuclei recoiling from the beta-decay of laser trapped neon isotopes. This distribution is sensitive to several new physics effects in the weak sector. Our `decay microscope' relies on imaging the velocity distribution of high energy recoil ions in coincidence with electrons shaken-o…
▽ More
We review the design, simulation, and tests, of a detection system for measuring the energy distribution of daughter nuclei recoiling from the beta-decay of laser trapped neon isotopes. This distribution is sensitive to several new physics effects in the weak sector. Our `decay microscope' relies on imaging the velocity distribution of high energy recoil ions in coincidence with electrons shaken-off in the decay. We demonstrate by way of Monte-Carlo simulation, that the nuclear microscope increases the statistical sensitivity of kinematic measurements to the underlying energy distribution, and limits the main systematic bias caused by discrepancy in the trap position along the detection axis.
△ Less
Submitted 23 February, 2020; v1 submitted 28 October, 2019;
originally announced October 2019.
-
Isotope shifts in $^{20,22}$Ne -- Precision measurements and global analysis in the framework of intermediate coupling
Authors:
B. Ohayon,
H. Rahangdale,
A. J. Geddes,
J. C. Berengut,
G. Ron
Abstract:
We report new precision measurements of the $^{20}$Ne--$^{22}$Ne isotope shift for several transitions, as well as state-of-the-art, \textit{ab initio} field-shift calculations. Our results are combined with historical measurements in a global fit to obtain the isotope shifts of all fifty low-lying neon levels with high precision. These level shifts show a wealth of electronic, nuclear, and relati…
▽ More
We report new precision measurements of the $^{20}$Ne--$^{22}$Ne isotope shift for several transitions, as well as state-of-the-art, \textit{ab initio} field-shift calculations. Our results are combined with historical measurements in a global fit to obtain the isotope shifts of all fifty low-lying neon levels with high precision. These level shifts show a wealth of electronic, nuclear, and relativistic phenomena. Relying on the analogy between mass shift and fine-structure operators, we explain this plethora of neon level-shifts utilizing a small number of effective parameters in a global parametric investigation. This investigation provides a birds-eye view on the isotope shift phenomena in noble gasses. From this vantage point, we reinterpret every effort made to calculate neon mass-shifts \textit{ab initio}, and show that a remarkable agreement between experiment and theory is obtained.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
Imaging recoil ions from optical collisions between ultracold, metastable neon isotopes
Authors:
B. Ohayon,
H. Rahangdale,
J. Chocron,
R. Kosloff,
O. Heber,
G. Ron
Abstract:
We present an experimental scheme which combines the well established method of velocity-mapimaging, with a cold trapped metastable neon target. The device is used for obtaining the branching ratios and recoil-ion energy distributions for the penning ionization process in optical collisions of ultracold metastable neon. The potential depth of the highly excited dimer potential is extracted and com…
▽ More
We present an experimental scheme which combines the well established method of velocity-mapimaging, with a cold trapped metastable neon target. The device is used for obtaining the branching ratios and recoil-ion energy distributions for the penning ionization process in optical collisions of ultracold metastable neon. The potential depth of the highly excited dimer potential is extracted and compared with theoretical calculations. The simplicity to construct, characterize and apply such a device, makes it a unique tool for the low-energy nuclear physics community, enabling opportunities for precision measurements in beta- and beta-delayed-neutron decays of cold, trapped, short-lived radioactive isotopes.
△ Less
Submitted 3 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
The Soreq Applied Research Accelerator Facility (SARAF) - Overview, Research Programs and Future Plans
Authors:
Israel Mardor,
Ofer Aviv,
Marilena Avrigeanu,
Dan Berkovits,
Adi Dahan,
Timo Dickel,
Ilan Eliyahu,
Moshe Gai,
Inbal Gavish-Segev,
Shlomi Halfon,
Michael Hass,
Tsviki Hirsh,
Boaz Kaiser,
Daniel Kijel,
Arik Kreisel,
Yonatan Mishnayot,
Ish Mukul,
Ben Ohayon,
Michael Paul,
Amichay Perry,
Hitesh Rahangdale,
Jacob Rodnizki,
Guy Ron,
Revital Sasson-Zukran,
Asher Shor
, et al. (4 additional authors not shown)
Abstract:
The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW de…
▽ More
The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW deuterons) is already in operation, generating scientific results in several fields of interest. The main ongoing program at SARAF-I is the production of 30 keV neutrons and measurement of Maxwellian Averaged Cross Sections (MACS), important for the astrophysical s-process. The world leading Maxwellian epithermal neutron yield at SARAF-I ($5\times 10^{10}$ epithermal neutrons/sec), generated by a novel Liquid-Lithium Target (LiLiT), enables improved precision of known MACSs, and new measurements of low-abundance and radioactive isotopes. Research plans for SARAF-II span several disciplines: Precision studies of beyond-Standard-Model effects by trapping light exotic radioisotopes, such as $^6$He, $^8$Li and $^{18,19,23}$Ne, in unprecedented amounts (including meaningful studies already at SARAF-I); extended nuclear astrophysics research with higher energy neutrons, including generation and studies of exotic neutron-rich isotopes relevant to the rapid (r-) process; nuclear structure of exotic isotopes; high energy neutron cross sections for basic nuclear physics and material science research, including neutron induced radiation damage; neutron based imaging and therapy; and novel radiopharmaceuticals development and production. In this paper we present a technical overview of SARAF-I and II, including a description of the accelerator and its irradiation targets; a survey of existing research programs at SARAF-I; and the research potential at the completed facility (SARAF-II).
△ Less
Submitted 23 January, 2018; v1 submitted 19 January, 2018;
originally announced January 2018.
-
Measurement of the $^{20-22}$Ne $^3$P$_2$-$^3$D$_3$ transition isotope shift using a single, phase modulated laser beam
Authors:
Ben Ohayon,
Gal Gumpel,
Guy Ron
Abstract:
We develop a simple technique to accurately measure frequency differences between far lying resonances in a spectroscopy signal using a single laser. This technique was used to measure the isotope shift of the cooling transition of metastable neon for the result of $1626.264(79)$ MHz. The most accurate determination of this value to date.
We develop a simple technique to accurately measure frequency differences between far lying resonances in a spectroscopy signal using a single laser. This technique was used to measure the isotope shift of the cooling transition of metastable neon for the result of $1626.264(79)$ MHz. The most accurate determination of this value to date.
△ Less
Submitted 13 February, 2017; v1 submitted 22 September, 2016;
originally announced September 2016.
-
Characterization of a metastable neon beam extracted from a commercial RF ion source
Authors:
B. Ohayon,
E. Wåhlin,
G. Ron
Abstract:
We have used a commercial RF ion-source to extract a beam of metastable neon atoms. The source was easily incorporated into our existing system and was operative within a day of installation. The metastable velocity distribution, flux, flow, and efficiency were investigated for different RF powers and pressures, and an optimum was found at a flux density of $2\times10^{12}\,$atoms/s/sr. To obtain…
▽ More
We have used a commercial RF ion-source to extract a beam of metastable neon atoms. The source was easily incorporated into our existing system and was operative within a day of installation. The metastable velocity distribution, flux, flow, and efficiency were investigated for different RF powers and pressures, and an optimum was found at a flux density of $2\times10^{12}\,$atoms/s/sr. To obtain an accurate measurement of the amount of metastable atoms leaving the source, we insert a Faraday cup in the beam line and quench some of them using a weak $633\,$nm laser beam. In order to determine how much of the beam was quenched before reaching our detector, we devised a simple model for the quenching transition and investigated it for different laser powers. This detection method can be easily adapted to other noble gas atoms.
△ Less
Submitted 21 November, 2014;
originally announced February 2015.
-
New Approaches in designing a Zeeman-Slower
Authors:
Ben Ohayon,
Guy Ron
Abstract:
We present two new approaches for the design of a Zeeman-Slower, which rely on optimal compliance with the adiabatic following condition and are applicable to a wide variety of systems. The first approach is an analytical one, based on the assumption that the noise in the system is position independent. When compared with the traditional approach, which requires constant deceleration, for a typica…
▽ More
We present two new approaches for the design of a Zeeman-Slower, which rely on optimal compliance with the adiabatic following condition and are applicable to a wide variety of systems. The first approach is an analytical one, based on the assumption that the noise in the system is position independent. When compared with the traditional approach, which requires constant deceleration, for a typical system, we show an improvement of $\sim$ 10% in the maximal capture velocity, allowing for a larger slower acceptance, or a reduction of $sim$ 25% in slower length, allowing for a simpler design and a better collimated beam. The second approach relies on an optimization of a system in which the magnetic field and the noise profile are well known. As an example, we use our 12-coil modular design and show an improvement of $sim$ 9% in maximal capture velocity or, alternatively, a reduction of $\sim$ 33% in slower length as compared with the traditional approach.
△ Less
Submitted 17 January, 2013; v1 submitted 10 December, 2012;
originally announced December 2012.