Systematic approach to measure the performance of microchannel-plate photomultipliers
Authors:
A. Lehmann,
M. Böhm,
M. Götz,
K. Gumbert,
S. Krauss,
D. Miehling,
M. Pfaffinger
Abstract:
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of MCP-PMTs. Measurements are shown for the following performance par…
▽ More
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of MCP-PMTs. Measurements are shown for the following performance parameters: spectral and spatial quantum efficiency, collection efficiency, gain as a function of voltage, position and magnetic field, time resolution, rate capability and lifetime. By using a dedicated 3-axis stepper and an FPGA-based DAQ system, also inner PMT parameters are measured as a function of the active area, such as relative detection efficiency, dark count rate, time resolution, recoil electron and afterpulse distributions, as well as charge sharing and electronic crosstalk. In addition, some of the parameters are investigated inside a strong magnetic field. For many of these measurements, the change of most setup parameters and the subsequent analysis can be controlled semi-automatically by software scripts.
△ Less
Submitted 4 July, 2024; v1 submitted 20 March, 2024;
originally announced March 2024.
-
The PANDA Barrel DIRC
Authors:
R. Dzhygadlo,
A. Belias,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
D. Miehling,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in t…
▽ More
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in the target region will be provided by a Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter. The Barrel DIRC, covering the polar angle range of 22-140 degrees, will provide a $π/K$ separation power of at least 3 standard deviations for charged particle momenta up to 3.5 GeV/c. The design of the Barrel DIRC features narrow radiator bars made from synthetic fused silica, an innovative multi-layer spherical lens focusing system, a prism-shaped synthetic fused silica expansion volume, and an array of lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs) to detect the hit location and arrival time of the Cherenkov photons. Detailed Monte-Carlo simulations were performed, and reconstruction methods were developed to study the performance of the system. All critical aspects of the design and the performance were validated with system prototypes in a mixed hadron beam at the CERN PS. In 2020 the PANDA Barrel DIRC project advanced from the design stage to component fabrication. The series production of the fused silica bars was successfully completed in 2021 and delivery of the MCP-PMTs started in May 2022.
△ Less
Submitted 12 January, 2024;
originally announced January 2024.
-
Performance of the most recent Microchannel-Plate PMTs for the PANDA DIRC detectors at FAIR
Authors:
S. Krauss,
M. Böhm,
K. Gumbert,
A. Lehmann,
D. Miehling,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier…
▽ More
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier) were the best choice of photon sensors for the DIRC detectors in the PANDA experiment. This paper will present the performance of some of the latest 2$\times$2 inch$^2$ MCP-PMTs from Photek and Photonis, including the first mass production tubes for the PANDA Barrel DIRC from Photonis. Performance parameters like the collection efficiency (CE), quantum efficiency (QE), and gain homogeneity were determined. The effect of magnetic fields on some properties like gain and charge cloud width was investigated as well. Apart from that the spatial distribution of many internal parameters like time resolution, dark count rate, afterpulse ratio, charge sharing crosstalk and recoil electrons were measured simultaneously with a multihit capable DAQ system. The latest generation of Photonis MCP-PMTs shows an unexpected "escalation" effect where the MCP-PMT itself produces photons.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
Lifetime and performance of the very latest microchannel-plate photomultipliers
Authors:
D. Miehling,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipli…
▽ More
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipliers (MCP-PMTs). Since the aging problems of MCP-PMTs were solved recently by coating the MCPs with the so-called ALD-technique (atomic layer deposition) we are investigating devices which are significantly improved with respect to other parameters, as, e.g., the collection efficiency (CE) and the quantum efficiency (QE). The latest generation of MCP-PMTs can reach a detective quantum efficiency DQE = QE - CE of 30%. This paper will present the performance of the most advanced 53 $\times$ 53 mm$^2$ ALD-coated MCP-PMTs from Photonis (8 $\times$ 8 and 3 $\times$ 100 anodes) and Photek (8 $\times$ 8 anodes), also inside the magnetic field. With a picosecond laser and a multi-hit capable DAQ system which allows read out up to 300 pixels simultaneously, parameters like darkcount rate, afterpulse probability and time resolution can be investigated as a function of incident photon position.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
PANDA Barrel DIRC: From Design to Component Production
Authors:
G Schepers,
A Belias,
R Dzhygadlo,
A Gerhardt,
D Lehmann,
K Peters,
C Schwarz,
J Schwiening,
M Traxler,
L Schmitt,
M Böhm,
S Krauss,
A Lehmann,
D Miehling,
M Pfaffinger,
M Düren,
E Etzelmüller,
K Föhl,
A Hayrapetyan,
I Köseoglu,
M Schmidt,
T Wasem,
C Sfienti,
A Ali,
A Barnyakov
, et al. (3 additional authors not shown)
Abstract:
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PM…
▽ More
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PMTs, started in 2018. In Sep. 2019 Nikon was selected to build the fused silica bars and successfully completed the series production of 112 bars in Feb. 2021. Measurements of the mechanical quality of the bars were performed by Nikon and the optical quality was evaluated at GSI. In Dec. 2020, the contract for the fabrication of the MCP-PMTs was awarded to PHOTONIS and the delivery of the first-of-series MCP-PMTs is expected in July 2021. We present the design of the PANDA Barrel DIRC as well as the status of the component series production and the result of the quality assurance measurements.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.