-
LEEx-B: Low Energy Experimental Bench Development at IPHC-CNRS Strasbourg
Authors:
E. Bouquerel,
T. Adama,
C. Maazouzi,
E. Traykov,
P. Graehling,
C. Mathieu
Abstract:
As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform and providing beams up to 25 keV. A beam profiler and an Allison-type emittance-meter allow the qualification of the setup and also the characterization of the…
▽ More
As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform and providing beams up to 25 keV. A beam profiler and an Allison-type emittance-meter allow the qualification of the setup and also the characterization of the beam. During the commissioning process, the electronics, and the control system were upgraded in order to push the limits towards low beam currents measured by the emittance-meter.
△ Less
Submitted 2 July, 2024;
originally announced July 2024.
-
Design and Commissioning of the first two CYRCé Extension Beamlines
Authors:
E. Bouquerel,
E. Traykov,
C. Maazouzi,
M. Rousseau,
M. Pellicioli,
J. Andrea,
T. Adam,
P. Graehling,
C. Mathieu,
G. Heitz,
M. Krauth,
D. Oster,
T. Foehrenbacher,
C. Ruescas,
J. Schuler,
U. Goerlach,
C. Haas
Abstract:
CYRCé is a TR24 cyclotron installed at the Institut Pluridisciplinaire Hubert Curien (IPHC) of Strasbourg operating at energies of 16-25 MeV and at intensities up to 400 $μ$A. The accelerator is used to produce and provide radioelements for PET and for SPECT. In 2015, IPHC started to develop a platform with the aim of performing radiobiological experiments. The PRECy platform foresees to contain t…
▽ More
CYRCé is a TR24 cyclotron installed at the Institut Pluridisciplinaire Hubert Curien (IPHC) of Strasbourg operating at energies of 16-25 MeV and at intensities up to 400 $μ$A. The accelerator is used to produce and provide radioelements for PET and for SPECT. In 2015, IPHC started to develop a platform with the aim of performing radiobiological experiments. The PRECy platform foresees to contain three-to-five experimental stations linked to beamlines expanded from the second exit port of the cyclotron. This extension allows devoting one of the beamlines for detector studies within the framework of the CMS project. The design, the development and the commissioning of the first two beamlines are discussed in this paper.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
New front and back-end electronics for the upgraded GABRIELA detection system
Authors:
K. Hauschild,
R. Chakma,
A. Lopez-Martens,
K. Rezynkina,
V. Alaphillipe,
L. Gibelin,
N. Karkour,
D. Linget,
A. V. Yeremin,
A. G. Popeko,
O. N. Malyshev,
V. I. Chepigin,
A. I. Svirikhin,
A. V. Isaev,
E. A. Sokol,
M. L. Chelnokov,
Yu. A. Popov,
D. E. Katrasev,
A. N. Kuznetsov,
A. A. Kuznetsova,
M. S. Tezekbayeva,
O. Dorvaux,
B. J. P. Gall,
P. Brionnet,
K. Kessaci
, et al. (1 additional authors not shown)
Abstract:
The GABRIELA [1] set-up is used at the FLNR to perform detailed nuclear structure studies of transfermium nuclei. Following the modernization of the VASSILISSA separator (SHELS) [2] the GABRIELA detection system has also been upgraded. The characteristics of the upgraded detection system will be presented along with results from some recent electronics tests.
The GABRIELA [1] set-up is used at the FLNR to perform detailed nuclear structure studies of transfermium nuclei. Following the modernization of the VASSILISSA separator (SHELS) [2] the GABRIELA detection system has also been upgraded. The characteristics of the upgraded detection system will be presented along with results from some recent electronics tests.
△ Less
Submitted 24 October, 2019;
originally announced October 2019.
-
Recent Results from Polycrystalline CVD Diamond Detectors
Authors:
RD42 Collaboration,
L. Bäni,
A. Alexopoulos,
M. Artuso,
F. Bachmair,
M. Bartosik,
H. Beck,
V. Bellini,
V. Belyaev,
B. Bentele,
A. Bes,
J. -M. Brom,
M. Bruzzi,
G. Chiodini,
D. Chren,
V. Cindro,
G. Claus,
J. Collot,
J. Cumalat,
A. Dabrowski,
R. D'Alessandro,
D. Dauvergne,
W. de Boer,
C. Dorfer,
M. Dünser
, et al. (87 additional authors not shown)
Abstract:
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse hei…
▽ More
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
Polarization dependent chemistry of ferroelectric BaTiO3 (001) domains
Authors:
Yanyu Mi,
Gregory Geneste,
Julien Rault,
Claire Mathieu,
Alexandre Pancotti,
Nicholas Barrett
Abstract:
Recent works suggest that the surface chemistry, in particular, the presence of oxygen vacancies can affect the polarization in a ferroelectric material. This should, in turn, influence the domain ordering driven by the need to screen the depolarizing field. Here we show using density functional theory that the presence of oxygen vacancies at the surface of BaTiO3 (001) preferentially stabilizes a…
▽ More
Recent works suggest that the surface chemistry, in particular, the presence of oxygen vacancies can affect the polarization in a ferroelectric material. This should, in turn, influence the domain ordering driven by the need to screen the depolarizing field. Here we show using density functional theory that the presence of oxygen vacancies at the surface of BaTiO3 (001) preferentially stabilizes an inward pointing, P-, polarization. Mirror electron microscopy measurements of the domain ordering confirm the theoretical results.
△ Less
Submitted 7 June, 2018;
originally announced June 2018.
-
Characterization of PARIS LaBr$_3$(Ce)-NaI(Tl) phoswich detectors upto $E_��$ $\sim$ 22 MeV
Authors:
C. Ghosh,
V. Nanal,
R. G. Pillay,
Anoop K. V,
N. Dokania,
Sanjoy Pal,
M. S. Pose,
G. Mishra,
P. C. Rout,
Suresh Kumar,
Deepak Pandit,
Debasish Mondal,
Surajit Pal,
S. R. Banerjee,
Paweł J. Napiorkowski,
Oliver Dorvaux,
S. Kihel,
C. Mathieu,
A. Maj
Abstract:
In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out. The detector response is investigated over a wide range of $E_γ$ = 0.6 to 22.6 MeV using radioactive sources and employing $^{11}B(p,γ)$ reaction at $E_p$ = 163 k…
▽ More
In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out. The detector response is investigated over a wide range of $E_γ$ = 0.6 to 22.6 MeV using radioactive sources and employing $^{11}B(p,γ)$ reaction at $E_p$ = 163 keV and $E_p$ = 7.2 MeV. The linearity of energy response of the LaBr$_3$(Ce) detector is tested upto 22.6 MeV using three different voltage dividers. The data acquisition system using CAEN digitizers is set up and optimized to get the best energy and time resolution. The energy resolution of $\sim$ 2.1% at $E_γ$ = 22.6~MeV is measured for the configuration giving best linearity upto high energy. Time resolution of the phoswich detector is measured with a $^{60}$Co source after implementing CFD algorithm for the digitized pulses and is found to be excellent (FWHM $\sim$ 315~ps). In order to study the effect of count rate on detectors, the centroid position and width of the $E_γ$ = 835~keV peak were measured upto 220 kHz count rate. The measured efficiency data with radioactive sources are in good agreement with GEANT4 based simulations. The total energy spectrum after the add-back of energy signals in phoswich components is also presented.
△ Less
Submitted 20 May, 2016; v1 submitted 3 May, 2016;
originally announced May 2016.
-
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Effect of Oxygen Adsorption on the Local Properties of Epitaxial Graphene on SiC (0001)
Authors:
C. Mathieu,
B. Lalmi,
T. O. Mentes,
E. Pallecchi,
A. Locatelli,
S. Latil,
R. Belkhou,
A. Ouerghi
Abstract:
The effect of oxygen adsorption on the local structure and electronic properties of monolayer graphene grown on SiC(0001) has been studied by means of Low Energy Electron Microscopy (LEEM), microprobe Low Energy Electron Diffraction (\muLEED) and microprobe Angle Resolved Photoemission (\muARPES). We show that the buffer layer of epitaxial graphene on SiC(0001) is partially decoupled after oxidati…
▽ More
The effect of oxygen adsorption on the local structure and electronic properties of monolayer graphene grown on SiC(0001) has been studied by means of Low Energy Electron Microscopy (LEEM), microprobe Low Energy Electron Diffraction (\muLEED) and microprobe Angle Resolved Photoemission (\muARPES). We show that the buffer layer of epitaxial graphene on SiC(0001) is partially decoupled after oxidation. The monitoring of the oxidation process demonstrates that the oxygen saturates the Si dangling bonds, breaks some Si-C bonds at the interface and intercalates the graphene layer. Accurate control over the oxidation parameters enables us to tune the charge density modulation in the layer.
△ Less
Submitted 12 June, 2012;
originally announced June 2012.