-
Quantum Electrodynamics in Strong Electromagnetic Fields: Substate Resolved K$α$ Transition Energies in Helium-like Uranium
Authors:
Philip Pfäfflein,
Günter Weber,
Steffen Allgeier,
Zoran Andelkovic,
Sonja Bernitt,
Andrey I. Bondarev,
Alexander Borovik,
Louis Duval,
Andreas Fleischmann,
Oliver Forstner,
Marvin Friedrich,
Jan Glorius,
Alexandre Gumberidze,
Christoph Hahn,
Daniel Hengstler,
Marc Oliver Herdrich,
Frank Herfurth,
Pierre-Michel Hillenbrand,
Anton Kalinin,
Markus Kiffer,
Felix Martin Kröger,
Maximilian Kubullek,
Patricia Kuntz,
Michael Lestinsky,
Yuri A. Litvinov
, et al. (12 additional authors not shown)
Abstract:
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED ca…
▽ More
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.
△ Less
Submitted 10 July, 2024; v1 submitted 4 July, 2024;
originally announced July 2024.
-
Storage, Accumulation and Deceleration of Secondary Beams for Nuclear Astrophysics
Authors:
J. Glorius,
Yu. A. Litvinov,
M. Aliotta,
F. Amjad,
B. Brückner,
C. G. Bruno,
R. Chen,
T. Davinson,
S. F. Dellmann,
T. Dickel,
I. Dillmann,
P. Erbacher,
O. Forstner,
H. Geissel,
C. J. Griffin,
R. Grisenti,
A. Gumberidze,
E. Haettner,
R. Hess,
P. -M. Hillenbrand,
C. Hornung,
R. Joseph,
B. Jurado,
E. Kazanseva,
R. Knöbel
, et al. (39 additional authors not shown)
Abstract:
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme…
▽ More
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme was pioneered to provide a secondary beam of $^{118}$Te$^{52+}$ for the measurement of nuclear proton-capture at energies of 6 and 7 MeV/u. The technique provided stored beam intensities of about $10^6$ ions at high purity and brilliance, representing a major step towards low-energy nuclear physics studies using rare ion beams.
△ Less
Submitted 30 May, 2023; v1 submitted 25 May, 2023;
originally announced May 2023.
-
Resistive Plate Chambers for Precise Measurement of High-Momentum Protons in Short Range Correlations at R$^3$B
Authors:
M. Xarepe,
T. Aumann,
A. Blanco,
A. Corsi,
D. Galaviz,
H. Johansson,
S. Linev,
B. Löher,
L. Lopes,
J. Michel,
V. Panin,
D. Rossi,
J. Saraiva,
H. Törnqvist,
M. Traxler
Abstract:
The Reactions with Relativistic Radioactive Beams (R$^3$B) collaboration of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, has constructed an experimental setup to perform fundamental studies of nuclear matter, using as a probe reactions with exotic nuclei at relativistic energies. Among the various detection systems, one of the most recent upgrades consisted on the ins…
▽ More
The Reactions with Relativistic Radioactive Beams (R$^3$B) collaboration of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, has constructed an experimental setup to perform fundamental studies of nuclear matter, using as a probe reactions with exotic nuclei at relativistic energies. Among the various detection systems, one of the most recent upgrades consisted on the installation of a large area, around 2 m$^2$, multi-gap Resistive Plate Chamber (RPC), equipped with twelve 0.3 mm gaps and readout by 30 mm pitch strips, exhibiting a timing precision down to 50 ps and efficiencies above 98% for MIPs in a previous characterization of the detector. The RPC was part of the setup of the FAIR Phase 0 experiment that focused on measuring, for the first time, nucleon-nucleon short-range correlations (SRC) inside an exotic nucleus ($^{16}$C) that occurred in Spring 2022. The excellent timing precision of this detector will allow the measurement of the forward emitted proton momentum with a resolution of around 1%. In beam measurements show an RPC efficiency above 95% and a time precision better than 100 ps (including the contribution of a reference scintillator and the momentum spread of the particles) for forward emitted particles.
△ Less
Submitted 11 December, 2022;
originally announced December 2022.
-
Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRING@ESR electron cooler
Authors:
Ph. Pfäfflein,
S. Bernitt,
Ch. Hahn,
M. O. Herdrich,
F. M. Kröger,
E. B. Menz,
T. Over,
B. Zhu,
Th. Stöhlker,
G. Weber,
S. Allgeier,
M. Friedrich,
D. Hengstler,
P. Kuntz,
A. Fleischmann,
Ch. Enss,
A. Kalinin,
M. Lestinsky,
B. Löher,
U. Spillmann
Abstract:
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to…
▽ More
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors' time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
△ Less
Submitted 1 February, 2022;
originally announced February 2022.
-
Electron capture of Xe$^{54+}$ in collisions with H${_2}$ molecules in the energy range between 5.5 MeV/u and 30.9 MeV/u
Authors:
F. M. Kröger,
G. Weber,
M. O. Herdrich,
J. Glorius,
C. Langer,
Z. Slavkovská,
L. Bott,
C. Brandau,
B. Brückner,
K. Blaum,
X. Chen,
S. Dababneh,
T. Davinson,
P. Erbacher,
S. Fiebiger,
T. Gaßner,
K. Göbel,
M. Groothuis,
A. Gumberidze,
Gy. Gyürky,
S. Hagmann,
C. Hahn,
M. Heil,
R. Hess,
R. Hensch
, et al. (41 additional authors not shown)
Abstract:
The electron capture process was studied for Xe$^{54+}$ colliding with H$_2$ molecules at the internal gas target of the ESR storage ring at GSI, Darmstadt. Cross section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogen-like ions subsequent to the capture of a target electron. The ion…
▽ More
The electron capture process was studied for Xe$^{54+}$ colliding with H$_2$ molecules at the internal gas target of the ESR storage ring at GSI, Darmstadt. Cross section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogen-like ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 MeV/u and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron capture data was recorded at the intermediate and in particular the low collision energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data is found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.
△ Less
Submitted 10 May, 2020; v1 submitted 5 May, 2020;
originally announced May 2020.
-
VME Readout at and Below the Conversion Time Limit
Authors:
M. Munch,
J. H. Jensen,
B. Löher,
H. Törnqvist,
H. T. Johansson
Abstract:
The achievable acquisition rates of modern triggered nuclear physics experiments are heavily dependent on the readout software, in addition to the limits given by the utilized hardware. This paper presents an asynchronous readout scheme that significantly improves the livetime of an otherwise synchronous triggered VME-based data acquisition system. A detailed performance analysis of this and other…
▽ More
The achievable acquisition rates of modern triggered nuclear physics experiments are heavily dependent on the readout software, in addition to the limits given by the utilized hardware. This paper presents an asynchronous readout scheme that significantly improves the livetime of an otherwise synchronous triggered VME-based data acquisition system. A detailed performance analysis of this and other readout schemes, in terms of the basic data transfer operations, is described. The performance of the newly developed scheme as well as synchronous schemes on two systems has been measured. The measurements show excellent agreement with the detailed description. For the second system, which previously used a synchronous readout, the deadtime ratio is at a 20 kHz trigger request frequency reduced by 30 % compared to the nearest contender, allowing 10 % more events to be recorded in the same time. The interaction between the network and readout tasks for single-core processors is also investigated. A livetime ratio loss of a few percent can be observed, depending on the size of the data chunks given to the operating system kernel for network transfer. With appropriately chosen chunk size, the effect can be mitigated.
△ Less
Submitted 1 December, 2018; v1 submitted 3 October, 2018;
originally announced October 2018.
-
The high-efficiency γ-ray spectroscopy setup γ3 at HIγS
Authors:
Bastian Löher,
Vera Derya,
Thomas Aumann,
Jacob Beller,
Nathan Cooper,
Marc Duchene,
Janis Endres,
Enrico Fiori,
Johann Isaak,
John Kelley,
Michael Knörzer,
Norbert Pietralla,
Christopher Romig,
Marcus Scheck,
Heiko Scheit,
Joel Silva,
Anton P. Tonchev,
Werner Tornow,
Henry Weller,
Volker Werner,
Andreas Zilges
Abstract:
The existing Nuclear Resonance Fluorescence (NRF) setup at the HIγS facility at the Triangle Universities Nuclear Laboratory at Duke University has been extended in order to perform γ-γ coincidence experiments. The new setup combines large volume LaBr3:Ce detectors and high resolution HPGe detectors in a very close geometry to offer high efficiency, high energy resolution as well as high count rat…
▽ More
The existing Nuclear Resonance Fluorescence (NRF) setup at the HIγS facility at the Triangle Universities Nuclear Laboratory at Duke University has been extended in order to perform γ-γ coincidence experiments. The new setup combines large volume LaBr3:Ce detectors and high resolution HPGe detectors in a very close geometry to offer high efficiency, high energy resolution as well as high count rate capabilities at the same time. The combination of a highly efficient γ-ray spectroscopy setup with the mono-energetic high-intensity photon beam of HIγS provides a worldwide unique experimental facility to investigate the γ-decay pattern of dipole excitations in atomic nuclei. The performance of the new setup has been assessed by studying the nucleus \sulfur at 8.125 MeV beam energy. The γ-decay branching ratio from the $1^+$ level at 8125.4 keV to the first excited $2^+$ state was determined to 15.7(3)%.
△ Less
Submitted 23 April, 2013;
originally announced April 2013.
-
Particle identification using clustering algorithms
Authors:
R. Wirth,
E. Fiori,
B. Löher,
D. Savran,
J. Silva,
H. Álvarez Pol,
D. Cortina Gil,
B. Pietras,
T. Bloch,
T. Kröll,
E. Nácher,
Á. Perea,
O. Tengblad,
M. Bendel,
M. Dierigl,
R. Gernhäuser,
T. Le Bleis,
M. Winkel
Abstract:
A method that uses fuzzy clustering algorithms to achieve particle identification based on pulse shape analysis is presented. The fuzzy c-means clustering algorithm is used to compute mean (principal) pulse shapes induced by different particle species in an automatic and unsupervised fashion from a mixed set of data. A discrimination amplitude is proposed using these principal pulse shapes to iden…
▽ More
A method that uses fuzzy clustering algorithms to achieve particle identification based on pulse shape analysis is presented. The fuzzy c-means clustering algorithm is used to compute mean (principal) pulse shapes induced by different particle species in an automatic and unsupervised fashion from a mixed set of data. A discrimination amplitude is proposed using these principal pulse shapes to identify the originating particle species of a detector pulse. Since this method does not make any assumptions about the specific features of the pulse shapes, it is very generic and suitable for multiple types of detectors. The method is applied to discriminate between photon- and proton-induced signals in CsI(Tl) scintillator detectors and the results are compared to the well-known integration method.
△ Less
Submitted 5 April, 2013;
originally announced April 2013.
-
High count rate γ-ray spectroscopy with LaBr3:Ce scintillation detectors
Authors:
B. Löher,
D. Savran,
E. Fiori,
M. Miklavec,
N. Pietralla,
M. Vencelj
Abstract:
The applicability of LaBr3:Ce detectors for high count rate γ-ray spectroscopy is investigated. A 3"x3" LaBr3:Ce detector is used in a test setup with radioactive sources to study the dependence of energy resolution and photo peak efficiency on the overall count rate in the detector. Digitized traces were recorded using a 500 MHz FADC and analysed with digital signal processing methods. In additio…
▽ More
The applicability of LaBr3:Ce detectors for high count rate γ-ray spectroscopy is investigated. A 3"x3" LaBr3:Ce detector is used in a test setup with radioactive sources to study the dependence of energy resolution and photo peak efficiency on the overall count rate in the detector. Digitized traces were recorded using a 500 MHz FADC and analysed with digital signal processing methods. In addition to standard techniques a pile-up correction method is applied to the data in order to further improve the high-rate capabilities and to reduce the losses in efficiency due to signal pile-up. It is shown, that γ-ray spectroscopy can be performed with high resolution at count rates even above 1 MHz and that the performance can be enhanced in the region between 500 kHz and 10 MHz by using pile-up correction techniques.
△ Less
Submitted 10 May, 2012; v1 submitted 29 February, 2012;
originally announced February 2012.