-
Systematic approach to measure the performance of microchannel-plate photomultipliers
Authors:
A. Lehmann,
M. Böhm,
M. Götz,
K. Gumbert,
S. Krauss,
D. Miehling,
M. Pfaffinger
Abstract:
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of MCP-PMTs. Measurements are shown for the following performance par…
▽ More
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of MCP-PMTs. Measurements are shown for the following performance parameters: spectral and spatial quantum efficiency, collection efficiency, gain as a function of voltage, position and magnetic field, time resolution, rate capability and lifetime. By using a dedicated 3-axis stepper and an FPGA-based DAQ system, also inner PMT parameters are measured as a function of the active area, such as relative detection efficiency, dark count rate, time resolution, recoil electron and afterpulse distributions, as well as charge sharing and electronic crosstalk. In addition, some of the parameters are investigated inside a strong magnetic field. For many of these measurements, the change of most setup parameters and the subsequent analysis can be controlled semi-automatically by software scripts.
△ Less
Submitted 4 July, 2024; v1 submitted 20 March, 2024;
originally announced March 2024.
-
The PANDA Barrel DIRC
Authors:
R. Dzhygadlo,
A. Belias,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
D. Miehling,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in t…
▽ More
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in the target region will be provided by a Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter. The Barrel DIRC, covering the polar angle range of 22-140 degrees, will provide a $π/K$ separation power of at least 3 standard deviations for charged particle momenta up to 3.5 GeV/c. The design of the Barrel DIRC features narrow radiator bars made from synthetic fused silica, an innovative multi-layer spherical lens focusing system, a prism-shaped synthetic fused silica expansion volume, and an array of lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs) to detect the hit location and arrival time of the Cherenkov photons. Detailed Monte-Carlo simulations were performed, and reconstruction methods were developed to study the performance of the system. All critical aspects of the design and the performance were validated with system prototypes in a mixed hadron beam at the CERN PS. In 2020 the PANDA Barrel DIRC project advanced from the design stage to component fabrication. The series production of the fused silica bars was successfully completed in 2021 and delivery of the MCP-PMTs started in May 2022.
△ Less
Submitted 12 January, 2024;
originally announced January 2024.
-
Performance of the most recent Microchannel-Plate PMTs for the PANDA DIRC detectors at FAIR
Authors:
S. Krauss,
M. Böhm,
K. Gumbert,
A. Lehmann,
D. Miehling,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier…
▽ More
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier) were the best choice of photon sensors for the DIRC detectors in the PANDA experiment. This paper will present the performance of some of the latest 2$\times$2 inch$^2$ MCP-PMTs from Photek and Photonis, including the first mass production tubes for the PANDA Barrel DIRC from Photonis. Performance parameters like the collection efficiency (CE), quantum efficiency (QE), and gain homogeneity were determined. The effect of magnetic fields on some properties like gain and charge cloud width was investigated as well. Apart from that the spatial distribution of many internal parameters like time resolution, dark count rate, afterpulse ratio, charge sharing crosstalk and recoil electrons were measured simultaneously with a multihit capable DAQ system. The latest generation of Photonis MCP-PMTs shows an unexpected "escalation" effect where the MCP-PMT itself produces photons.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
Lifetime and performance of the very latest microchannel-plate photomultipliers
Authors:
D. Miehling,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipli…
▽ More
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipliers (MCP-PMTs). Since the aging problems of MCP-PMTs were solved recently by coating the MCPs with the so-called ALD-technique (atomic layer deposition) we are investigating devices which are significantly improved with respect to other parameters, as, e.g., the collection efficiency (CE) and the quantum efficiency (QE). The latest generation of MCP-PMTs can reach a detective quantum efficiency DQE = QE - CE of 30%. This paper will present the performance of the most advanced 53 $\times$ 53 mm$^2$ ALD-coated MCP-PMTs from Photonis (8 $\times$ 8 and 3 $\times$ 100 anodes) and Photek (8 $\times$ 8 anodes), also inside the magnetic field. With a picosecond laser and a multi-hit capable DAQ system which allows read out up to 300 pixels simultaneously, parameters like darkcount rate, afterpulse probability and time resolution can be investigated as a function of incident photon position.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
PANDA Barrel DIRC: From Design to Component Production
Authors:
G Schepers,
A Belias,
R Dzhygadlo,
A Gerhardt,
D Lehmann,
K Peters,
C Schwarz,
J Schwiening,
M Traxler,
L Schmitt,
M Böhm,
S Krauss,
A Lehmann,
D Miehling,
M Pfaffinger,
M Düren,
E Etzelmüller,
K Föhl,
A Hayrapetyan,
I Köseoglu,
M Schmidt,
T Wasem,
C Sfienti,
A Ali,
A Barnyakov
, et al. (3 additional authors not shown)
Abstract:
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PM…
▽ More
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PMTs, started in 2018. In Sep. 2019 Nikon was selected to build the fused silica bars and successfully completed the series production of 112 bars in Feb. 2021. Measurements of the mechanical quality of the bars were performed by Nikon and the optical quality was evaluated at GSI. In Dec. 2020, the contract for the fabrication of the MCP-PMTs was awarded to PHOTONIS and the delivery of the first-of-series MCP-PMTs is expected in July 2021. We present the design of the PANDA Barrel DIRC as well as the status of the component series production and the result of the quality assurance measurements.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
Acoustics of Margravial Opera House Bayreuth
Authors:
Sebastian Krauss,
Simeon Völkel,
Christoph Dobner,
Alexandra Völkel,
Kai Huang
Abstract:
The Margravial Opera House Bayreuth, built between 1745 and 1750, is a well preserved Baroque court theatre designed by Giuseppe Galli Bibiena [1]. It provides an opportunity to experience not only the visual but also the acoustic design of opera theatres in the 18th century, as the bell-shaped auditorium along with the decoratively painted canvas remains intact. Using balloons and hand-claps as s…
▽ More
The Margravial Opera House Bayreuth, built between 1745 and 1750, is a well preserved Baroque court theatre designed by Giuseppe Galli Bibiena [1]. It provides an opportunity to experience not only the visual but also the acoustic design of opera theatres in the 18th century, as the bell-shaped auditorium along with the decoratively painted canvas remains intact. Using balloons and hand-claps as sound sources, we characterize the impulse response of this opera house after its recent renovation. The reverberation time (RT), early decay time (EDT) and clarity factor are characterized and discussed in comparison to historical Italian theatres of a similar age.
△ Less
Submitted 31 May, 2019;
originally announced May 2019.
-
Multiple satellite analysis of the Earth's thermosphere and interplanetary magnetic field variations due to ICME/CIR events during 2003-2015
Authors:
Sandro Krauss,
Manuela Temmer,
Susanne Vennerstroem
Abstract:
We present a refined statistical analysis based on interplanetary coronal mass ejections as well as co-rotating interaction regions for the time period 2003-2015 to estimate the impact of different solar wind types on the geomagnetic activity and the neutral density in the Earth's thermosphere. For the time-based delimitation of the events, we rely on the catalog maintained by Richardson and Cane…
▽ More
We present a refined statistical analysis based on interplanetary coronal mass ejections as well as co-rotating interaction regions for the time period 2003-2015 to estimate the impact of different solar wind types on the geomagnetic activity and the neutral density in the Earth's thermosphere. For the time-based delimitation of the events, we rely on the catalog maintained by Richardson and Cane and the CIR-lists provided by S. Vennerstroem and Jian et al. [2011]. These archives are based on in-situ measurements from the ACE and/or the Wind spacecraft. On this basis, we thoroughly investigated 196 Earth-directed ICME and 195 CIR events. To verify the impact on the Earth's thermosphere we determined neutral mass densities by using accelerometer measurements collected by the low-Earth orbiting satellites GRACE and CHAMP. Subsequently, the atmospheric densities are related to characteristic ICME parameters. In this process a new calibration method has been examined. Since increased solar activity may lead to a decrease of the satellites orbital altitude we additionally assessed the orbital decay for each of the events and satellites. The influence of CIR events is in the same range of magnitude as the majority of the ICMEs (186 out of 196). Even though, the extended investigation period between 2011 and 2015 has a lack of extreme solar events the combined analysis reveals comparable correlation coefficients between the neutral densities and the various ICME and geomagnetic parameters (mostly > 0.85). The evaluation of orbit decay rates at different altitudes revealed a high dependency on the satellite actual altitude.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
Thermosphere and geomagnetic response to interplanetary coronal mass ejections observed by ACE and GRACE: Statistical results
Authors:
S. Krauss,
M. Temmer,
A. M. Veronig,
O. Baur,
H. Lammer
Abstract:
For the period July 2003 to August 2010, the interplanetary coronal mass ejection (ICME) catalogue maintained by Richardson and Cane lists 106 Earth-directed events, which have been measured in-situ by plasma and field instruments onboard the ACE satellite. We present a statistical investigation of the Earth's thermospheric neutral density response by means of accelerometer measurements collected…
▽ More
For the period July 2003 to August 2010, the interplanetary coronal mass ejection (ICME) catalogue maintained by Richardson and Cane lists 106 Earth-directed events, which have been measured in-situ by plasma and field instruments onboard the ACE satellite. We present a statistical investigation of the Earth's thermospheric neutral density response by means of accelerometer measurements collected by the GRACE satellites, which are available for 104 ICMEs in the data set, and its relation to various geomagnetic indices and characteristic ICME parameters such as the impact speed, southward magnetic field strength (Bz). The majority of ICMEs causes a distinct density enhancement in the thermosphere, with up to a factor of eight compared to the pre-event level. We find high correlations between ICME Bz and thermospheric density enhancements (~0.9), while the correlation with the ICME impact speed is somewhat smaller (~0.7). The geomagnetic indices revealing the highest correlations are Dst and SYM-H (~0.9), the lowest correlations are obtained for kp and AE (~0.7), which show a nonlinear relation with the thermospheric density enhancements. Separating the response for the shock sheath region and the magnetic structure of the ICME, we find that the Dst and SYM-H reveal a tighter relation to the Bz minimum in the magnetic structure of the ICME, whereas the polar cap indices show higher correlations with the Bz minimum in the shock sheath region. Since the strength of the Bz component - either in the sheath or the magnetic structure of the ICME - is highly correlated (~0.9) with the neutral density enhancement, we discuss the possibility of satellite orbital decay estimates based on magnetic field measurements at L1, i.e. before the ICME hits the Earth's magnetosphere. This will further stimulate progress in space weather understanding and applications regarding satellite operations.
△ Less
Submitted 13 October, 2015;
originally announced October 2015.