-
An analytic, moment-based method to estimate orthopositronium lifetimes in positron annihilation lifetime spectroscopy measurements
Authors:
Lucas Berens,
Isaac Hsu,
Chin-Tu Chen,
Howard Halpern,
Chien-Min Kao
Abstract:
The presence of tumor hypoxia is known to correlate with poor patient prognosis. Measurement of tissue oxygen concentration can be challenging, but recent advancements using positron annihilation lifetime spectroscopy (PALS) in three-dimensional positron emission tomography (PET) scans have shown promise for hypoxia detection. In this work, a novel method for estimating the orthopositronium lifeti…
▽ More
The presence of tumor hypoxia is known to correlate with poor patient prognosis. Measurement of tissue oxygen concentration can be challenging, but recent advancements using positron annihilation lifetime spectroscopy (PALS) in three-dimensional positron emission tomography (PET) scans have shown promise for hypoxia detection. In this work, a novel method for estimating the orthopositronium lifetime in PALS is presented. This method is analytical and uses moments of the time-difference histogram from photon arrival times. For sufficient statistical power, the method produces monotonic, stable estimates. For cases with a lower number of photon counts, the method was characterized and solutions are presented to correct for bias and estimation variability.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
A new radiobiology-based HDR brachytherapy treatment planning algorithm used to investigate the potential for hypofractionation in cervical cancer
Authors:
Kaelyn Seeley,
I-Chow J. Hsu,
Tae Min Hong,
J. Adam Cunha
Abstract:
Most commercially available treatment planning systems for brachytherapy operate based on physical dose and do not incorporate fractionation or tissue-specific response. The purpose of this study is to investigate the potential for hypofractionation in HDR brachytherapy, thereby reducing the number of implants required. A new treatment planning algorithm was built in order to optimize based on tis…
▽ More
Most commercially available treatment planning systems for brachytherapy operate based on physical dose and do not incorporate fractionation or tissue-specific response. The purpose of this study is to investigate the potential for hypofractionation in HDR brachytherapy, thereby reducing the number of implants required. A new treatment planning algorithm was built in order to optimize based on tissue and fractionation specific parameters. Different fractionation schemes were considered for 6 patients, and plans were created using the new algorithm. A baseline fractionation scheme consisting of 5 fractions was compared to hypofractionated plans of 1 to 4 fractions. The effectiveness of each plan was evaluated using radiobiological criteria taken from GEC-ESTRO guidelines. The results of this study indicate that an optimization algorithm based on biological parameters has similar functionality to traditional planning methods with the additional ability to account for fractionation effects. Using this algorithm, it was shown that plans consisting of 3 and 4 fractions have comparable target coverage with equivalent normal tissue exposure. In some specific cases, further fractionation may present acceptable target coverage as well.
△ Less
Submitted 30 November, 2017;
originally announced December 2017.
-
IPIP: A New Approach to Inverse Planning for HDR Brachytherapy by Directly Optimizing Dosimetric Indices
Authors:
Timmy Siauw,
Adam Cunha,
Alper Atamturk,
I-Chow Hsu,
Jean Pouliot,
Ken Goldberg
Abstract:
Purpose: Many planning methods for high dose rate (HDR) brachytherapy treatment planning require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the…
▽ More
Purpose: Many planning methods for high dose rate (HDR) brachytherapy treatment planning require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to improve HDR brachytherapy planning by developing a new approach that directly optimizes the dose distribution based on dosimetric criteria.
Method: We develop Inverse Planning by Integer Program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. We used our heuristic to compute dose plans for 20 anonymized prostate cancer patient image data sets from our clinic database. Dosimetry was evaluated and compared to dosimetric criteria.
Results: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 seconds on a Intel(R) CoreTM2 Duo CPU 1.67 GHz processor with 3 Gib RAM.
Conclusion: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. We have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, both in terms of dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.
△ Less
Submitted 30 November, 2010;
originally announced December 2010.
-
Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns
Authors:
J. Adam M. Cunha,
I-Chow Hsu,
Jean Pouliot
Abstract:
Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma.
Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penil…
▽ More
Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma.
Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. On CT data from ten previously-treated patients new catheters were digitized following three catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage.
Results: Thirty plans from ten patients were optimized. All non-standard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk.
Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.
△ Less
Submitted 15 April, 2009;
originally announced April 2009.