-
Quantum Electrodynamics in Strong Electromagnetic Fields: Substate Resolved K$α$ Transition Energies in Helium-like Uranium
Authors:
Philip Pfäfflein,
Günter Weber,
Steffen Allgeier,
Zoran Andelkovic,
Sonja Bernitt,
Andrey I. Bondarev,
Alexander Borovik,
Louis Duval,
Andreas Fleischmann,
Oliver Forstner,
Marvin Friedrich,
Jan Glorius,
Alexandre Gumberidze,
Christoph Hahn,
Daniel Hengstler,
Marc Oliver Herdrich,
Frank Herfurth,
Pierre-Michel Hillenbrand,
Anton Kalinin,
Markus Kiffer,
Felix Martin Kröger,
Maximilian Kubullek,
Patricia Kuntz,
Michael Lestinsky,
Yuri A. Litvinov
, et al. (12 additional authors not shown)
Abstract:
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED ca…
▽ More
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.
△ Less
Submitted 10 July, 2024; v1 submitted 4 July, 2024;
originally announced July 2024.
-
MMC Array to Study X-ray Transitions in Muonic Atoms
Authors:
Daniel Unger,
Andreas Abeln,
Thomas Elias Cocolios,
Ofir Eizenberg,
Christian Enss,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Paul Indelicato,
Ashish Jadhav,
Daniel Kreuzberger,
Klaus Kirch,
Andreas Knecht,
Jorge Machado,
Ben Ohayon,
Nancy Paul,
Randolf Pohl,
Katharina von Schoeler,
Stergiani Marina Vogiatzi,
Frederik Wauters
Abstract:
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We di…
▽ More
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.
△ Less
Submitted 6 April, 2024; v1 submitted 20 November, 2023;
originally announced November 2023.
-
Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
Authors:
Ben Ohayon,
Andreas Abeln,
Silvia Bara,
Thomas Elias Cocolios,
Ofir Eizenberg,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Guillaume Hupin,
Paul Indelicato,
Klaus Kirch,
Andreas Knecht,
Daniel Kreuzberger,
Jorge Machado,
Petr Navratil,
Nancy Paul,
Randolf Pohl,
Daniel Unger,
Stella Vogiatzi,
Katharina von Schoeler,
Frederik Wauters
Abstract:
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyon…
▽ More
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
△ Less
Submitted 17 February, 2024; v1 submitted 5 October, 2023;
originally announced October 2023.
-
Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRING@ESR electron cooler
Authors:
Ph. Pfäfflein,
S. Bernitt,
Ch. Hahn,
M. O. Herdrich,
F. M. Kröger,
E. B. Menz,
T. Over,
B. Zhu,
Th. Stöhlker,
G. Weber,
S. Allgeier,
M. Friedrich,
D. Hengstler,
P. Kuntz,
A. Fleischmann,
Ch. Enss,
A. Kalinin,
M. Lestinsky,
B. Löher,
U. Spillmann
Abstract:
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to…
▽ More
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors' time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
△ Less
Submitted 1 February, 2022;
originally announced February 2022.
-
Multichannel read-out for arrays of metallic magnetic calorimeters
Authors:
F. Mantegazzini,
S. Allgeier,
A. Barth,
C. Enss,
A. Ferring-Siebert,
A. Fleischmann,
L. Gastaldo,
R. Hammann,
D. Hengstler,
S. Kempf,
D. Richter,
D. Schulz,
D. Unger,
C. Velte,
M. Wegner
Abstract:
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stopping power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MM…
▽ More
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stopping power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MMC arrays read out by 32 two-stage SQUID read-out channels. In contrast to the design of the detector array and consequently the design of the front-end SQUIDs, which need to be optimised for the physics case and the particles to be detected in a given experiment, the read-out chain can be standardised. We present our new standardised 32-channel parallel read-out for the operation of MMC arrays to be operated in a dilution refrigerator. The read-out system consists of a detector module, whose design depends on the particular application, an amplifier module, ribbon cables from room temperature to the millikelvin platform and a data acquisition system. In particular, we describe the realisation of the read-out system prepared for the ECHo-1k experiment for the operation of two 64-pixel arrays. The same read-out concept is also used for the maXs detector systems, developed for the study of the de-excitation of highly charged heavy ions by X-rays, as well as for the MOCCA system, developed for the energy and position sensitive detection of neutral molecular fragments for the study of fragmentation when molecular ions recombine with electrons. The choice of standard modular components for the operation of 32-channel MMC arrays offer the flexibility to upgrade detector modules without the need of any changes in the read-out system and the possibility to individually exchange parts in case of damages or failures.
△ Less
Submitted 13 October, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
High-resolution for IAXO: MMC-based X-ray Detectors
Authors:
D. Unger,
A. Abeln,
C. Enss,
A. Fleischmann,
D. Hengstler,
S. Kempf,
L. Gastaldo
Abstract:
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low ene…
▽ More
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low energy threshold would allow for investigating the ALP properties by studying the X-ray spectrum after its discovery. We propose to use low temperature metallic magnetic calorimeters (MMCs). Here we present the first detector system based on MMCs developed for IAXO and discuss the results of the characterization. The detector consists of a two-dimensional 64-pixel array covering an active area of 16 mm$^2$ with a fill factor of 93 %. We achieve an average energy resolution of 6.1 eV FWHM allowing for energy thresholds below 100 eV. This detector is the first step towards a larger 1 cm$^2$ array matching the IAXO X-ray optics. We determine the background rate for an unshielded detector system in the energy range between 1 keV and 10 keV to be $3.2(1) \times 10^{-4}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ from events acquired over 30 days. In the future, active and passive shields will significantly reduce the background induced by cosmic muons and natural radioactivity. Our results demonstrate that MMCs are a promising technology for helioscopes to discover and study ALPs.
△ Less
Submitted 8 June, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter
Authors:
Tomas Sikorsky,
Jeschua Geist,
Daniel Hengstler,
Sebastian Kempf,
Loredana Gastaldo,
Christian Enss,
Christoph Mokry,
Jörg Runke,
Christoph E. Düllmann,
Peter Wobrauschek,
Kjeld Beeks,
Veronika Rosecker,
Johannes H. Sterba,
Georgy Kazakov,
Thorsten Schumm,
Andreas Fleischmann
Abstract:
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme…
▽ More
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $γ$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be $b_{29}=9.3(6)\%$ and $b_{42}=0.3(3)\%$.
△ Less
Submitted 27 May, 2020;
originally announced May 2020.
-
Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments
Authors:
O. Novotný,
S. Allgeier,
C. Enss,
A. Fleischmann,
L. Gamer,
D. Hengstler,
S. Kempf,
C. Krantz,
A. Pabinger,
C. Pies,
D. W. Savin,
D. Schwalm,
A. Wolf
Abstract:
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecula…
▽ More
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.
△ Less
Submitted 12 June, 2015; v1 submitted 27 May, 2015;
originally announced May 2015.