Skip to main content

Showing 1–19 of 19 results for author: Götz, M

  1. arXiv:2403.13938  [pdf, other

    physics.ins-det

    Systematic approach to measure the performance of microchannel-plate photomultipliers

    Authors: A. Lehmann, M. Böhm, M. Götz, K. Gumbert, S. Krauss, D. Miehling, M. Pfaffinger

    Abstract: In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other locations, the document is intended as a guide for comparable measurements with other types of MCP-PMTs. Measurements are shown for the following performance par… ▽ More

    Submitted 4 July, 2024; v1 submitted 20 March, 2024; originally announced March 2024.

  2. arXiv:2403.08280  [pdf

    eess.IV cs.CV physics.med-ph q-bio.QM

    Pre-examinations Improve Automated Metastases Detection on Cranial MRI

    Authors: Katerina Deike-Hofmann, Dorottya Dancs, Daniel Paech, Heinz-Peter Schlemmer, Klaus Maier-Hein, Philipp Bäumer, Alexander Radbruch, Michael Götz

    Abstract: Materials and methods: First, a dual-time approach was assessed, for which the CNN was provided sequences of the MRI that initially depicted new MM (diagnosis MRI) as well as of a prediagnosis MRI: inclusion of only contrast-enhanced T1-weighted images (CNNdual_ce) was compared with inclusion of also the native T1-weighted images, T2-weighted images, and FLAIR sequences of both time points (CNNdua… ▽ More

    Submitted 13 March, 2024; originally announced March 2024.

    Journal ref: Investigative Radiology 56(5):p 320-327, May 2021

  3. arXiv:2312.15830  [pdf, other

    eess.SY physics.app-ph

    Hairpin Motors for Electromobility: Twists and Bends of a Technological Breakthrough that Initially Arrived A Century Too Soon

    Authors: Stefan M. Goetz, Ricardo Lizana F., Sebastian Rivera

    Abstract: There is currently a major trend to hairpin-winding motors for small and medium drives with increased power, specifically more torque density in the automotive industry. Practically all large players in the field either already use this winding technology or have announced doing so soon. However, hairpins, bar windings, and other segmented winding techniques are not purely a material and productio… ▽ More

    Submitted 25 December, 2023; originally announced December 2023.

    Comments: 22 pages, 20 figures

  4. arXiv:2208.14924  [pdf, other

    physics.comp-ph cs.LG

    Learning Tree Structures from Leaves For Particle Decay Reconstruction

    Authors: James Kahn, Ilias Tsaklidis, Oskar Taubert, Lea Reuter, Giulio Dujany, Tobias Boeckh, Arthur Thaller, Pablo Goldenzweig, Florian Bernlochner, Achim Streit, Markus Götz

    Abstract: In this work, we present a neural approach to reconstructing rooted tree graphs describing hierarchical interactions, using a novel representation we term the Lowest Common Ancestor Generations (LCAG) matrix. This compact formulation is equivalent to the adjacency matrix, but enables learning a tree's structure from its leaves alone without the prior assumptions required if using the adjacency mat… ▽ More

    Submitted 1 September, 2022; v1 submitted 31 August, 2022; originally announced August 2022.

    Comments: 14 pages, 6 figures, accepted in Machine Learning: Science and Technology

  5. arXiv:2202.06530  [pdf

    physics.med-ph physics.ins-det

    Modular Pulse Synthesizer for Transcranial Magnetic Stimulation with Flexible User-Defined Pulse Shaping and Rapidly Changing Pulses in Sequences

    Authors: Z. Li, J. Zhang, A. V. Peterchev, S. M. Goetz

    Abstract: The temporal shape of a pulse in transcranial magnetic stimulation (TMS) influences which neuron populations are activated preferentially as well as the strength and even direction of neuromodulation effects. Furthermore, various pulse shapes differ in their efficiency, coil heating, sensory perception, and clicking sound. However, the available TMS pulse shape repertoire is still very limited to… ▽ More

    Submitted 14 February, 2022; originally announced February 2022.

    Comments: 32 pages, 18 figures

    MSC Class: 92C50

  6. arXiv:2111.05315  [pdf

    q-bio.QM cs.CV eess.IV physics.bio-ph

    Stain-free Detection of Embryo Polarization using Deep Learning

    Authors: Cheng Shen, Adiyant Lamba, Meng Zhu, Ray Zhang, Changhuei Yang, Magdalena Zernicka Goetz

    Abstract: Polarization of the mammalian embryo at the right developmental time is critical for its development to term and would be valuable in assessing the potential of human embryos. However, tracking polarization requires invasive fluorescence staining, impermissible in the in vitro fertilization clinic. Here, we report the use of artificial intelligence to detect polarization from unstained time-lapse… ▽ More

    Submitted 8 November, 2021; originally announced November 2021.

  7. arXiv:2106.05023  [pdf, other

    physics.ins-det cond-mat.mes-hall physics.app-ph

    Improvements of the programmable quantum current generator for better traceability of electrical current measurements

    Authors: Sophie Djordjevic, Ralf Behr, Dietmar Drung, Martin Götz, Wilfrid Poirier

    Abstract: A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improve… ▽ More

    Submitted 9 June, 2021; originally announced June 2021.

    Comments: Accepted in Metrologia

  8. arXiv:2007.00746  [pdf

    physics.med-ph

    Double-containment coil with enhanced winding mounting for transcranial magnetic stimulation with reduced acoustic noise

    Authors: Lari M. Koponen, Stefan M. Goetz, Angel V. Peterchev

    Abstract: Objective: This work aims to reduce the acoustic noise level of transcranial magnetic stimulation (TMS) coils. TMS requires high currents (several thousand amperes) to be pulsed through the coil, which generates a loud acoustic impulse whose peak sound pressure level (SPL) can exceed 130 dB(Z). This sound poses a risk to hearing and elicits unwanted neural activation of auditory brain circuits. Me… ▽ More

    Submitted 1 July, 2020; originally announced July 2020.

    Comments: 8 pages, 5 figures

  9. arXiv:1912.04975  [pdf

    eess.SP physics.bio-ph q-bio.NC

    Integration of Simultaneous Resting-State Electroencephalography, Functional Magnetic Resonance Imaging, and Eye-Tracker Methods to Determine and Verify Electroencephalography Vigilance Measure

    Authors: Ahmad Mayeli, Obada Al Zoubi, Masaya Misaki, Jennifer L. Stewart, Vadim Zotev, Qingfei Luo, Raquel Phillips, Stefan Fischer, Marcus Goetz, Martin P. Paulus, Hazem Refai, Jerzy Bodurka

    Abstract: Background/Introduction: Concurrent electroencephalography and resting-state functional magnetic resonance imaging (rsfMRI) have been widely used for studying the (presumably) awake and alert human brain with high temporal/spatial resolution. Although rsfMRI scans are typically collected while individuals are instructed to focus their eyes on a fixated cross, objective and verified experimental me… ▽ More

    Submitted 19 June, 2021; v1 submitted 10 December, 2019; originally announced December 2019.

    Journal ref: Brain Connectivity 10.10 (2020): 535-546

  10. Heterogeneities Shape Passive Intracellular Transport

    Authors: P. Witzel, M. Götz, Y. Lanoiselée, T. Franosch, D. S. Grebenkov, D. Heinrich

    Abstract: A living cell's interior is one of the most complex and intrinsically dynamic systems, providing an elaborate interplay between cytosolic crowding and ATP-driven motion, which controls cellular functionality. Here, we investigated two distinct fundamental features of the merely passive, not-bio-motor shuttled material transport within the cytoplasm of Dictyostelium discoideum cells: the anomalous… ▽ More

    Submitted 12 November, 2019; originally announced November 2019.

    Journal ref: Biophys. J. 117, 203-213 (2019)

  11. Inter-laboratory nanoamp current comparison with sub-part-per-million uncertainty

    Authors: Stephen Giblin, Dietmar Drung, Martin Goetz, Hansjoerg Scherer

    Abstract: An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$. This is a new bench-mark for inter-laboratory transfer of small current. We describe in detail the use of a cryogenic current comparator to calibrate the ULCA at… ▽ More

    Submitted 29 August, 2018; originally announced August 2018.

    Comments: 8 pages, 7 figures

    Journal ref: IEEE transactions in instrumentation and measurement, 2019

  12. arXiv:1808.08881  [pdf

    physics.ins-det

    Electrometer calibration with sub-part-per-million uncertainty

    Authors: Hansjörg Scherer, Dietmar Drung, Christian Krause, Martin Götz, Ulrich Becker

    Abstract: We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the comprehensive characterization of the devices under test regarding noise, settling and burden voltage behavior as well as stability of the gain factor, and con… ▽ More

    Submitted 22 November, 2018; v1 submitted 27 August, 2018; originally announced August 2018.

    Comments: 7 pages, 10 figures, 23 references

  13. arXiv:1806.07156  [pdf

    q-bio.QM physics.bio-ph q-bio.BM

    Conformational dynamics of a single protein monitored for 24 hours at video rate

    Authors: Weixiang Ye, Markus Götz, Sirin Celiksoy, Laura Tüting, Christoph Ratzke, Janak Prasad, Rubén Ahijado-Guzmán, Thorsten Hugel, Carsten Sönnichsen

    Abstract: We use plasmon rulers to follow the conformational dynamics of a single protein for up to 24 h at a video rate. The plasmon ruler consists of two gold nanospheres connected by a single protein linker. In our experiment, we follow the dynamics of the molecular chaperone heat shock protein 90, which is known to show open and closed conformations. Our measurements confirm the previously known conform… ▽ More

    Submitted 5 October, 2018; v1 submitted 19 June, 2018; originally announced June 2018.

    MSC Class: 92

  14. arXiv:1710.04090  [pdf

    cond-mat.mes-hall physics.ins-det

    Zero-field quantum anomalous Hall metrology as a step towards a universal quantum standard unit system

    Authors: Martin Goetz, Kajetan M. Fijalkowski, Eckart Pesel, Matthias Hartl, Steffen Schreyeck, Martin Winnerlein, Stefan Grauer, Hansjoerg Scherer, Karl Brunner, Charles Gould, Franz J. Ahlers, Laurens W. Molenkamp

    Abstract: In the quantum anomalous Hall effect, the edge states of a ferromagnetically doped topological insulator exhibit quantized Hall resistance and dissipationless transport at zero magnetic field. Up to now, however, the resistance was experimentally assessed with standard transport measurement techniques which are difficult to trace to the von-Klitzing constant R$_K$ with high precision. Here, we pre… ▽ More

    Submitted 11 October, 2017; originally announced October 2017.

    Journal ref: Appl. Phys. Lett. 112, 072102 (2018)

  15. arXiv:1710.03807  [pdf, other

    q-bio.QM physics.bio-ph

    Precision and accuracy of single-molecule FRET measurements - a worldwide benchmark study

    Authors: Björn Hellenkamp, Sonja Schmid, Olga Doroshenko, Oleg Opanasyuk, Ralf Kühnemuth, Soheila Rezaei Adariani, Anders Barth, Victoria Birkedal, Mark E. Bowen, Hongtao Chen, Thorben Cordes, Tobias Eilert, Carel Fijen, Markus Götz, Giorgos Gouridis, Enrico Gratton, Taekjip Ha, Christian A. Hanke, Andreas Hartmann, Jelle Hendrix, Lasse L. Hildebrandt, Johannes Hohlbein, Christian G. Hübner, Eleni Kallis, Achillefs N. Kapanidis , et al. (28 additional authors not shown)

    Abstract: Single-molecule Förster resonance energy transfer (smFRET) is increasingly being used to determine distances, structures, and dynamics of biomolecules in vitro and in vivo. However, generalized protocols and FRET standards ensuring both the reproducibility and accuracy of measuring FRET efficiencies are currently lacking. Here we report the results of a worldwide, comparative, blind study, in whic… ▽ More

    Submitted 29 December, 2017; v1 submitted 10 October, 2017; originally announced October 2017.

    Comments: 27 pages, 5 figures, supplementary material, corrections: p20 last sentence; eqn. 13 & 14

    Journal ref: Natue Methods, vol. 15, pages 669-676, 2018

  16. Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents

    Authors: Dietmar Drung, Christian Krause, Stephen P. Giblin, Sophie Djordjevic, Francois Piquemal, Olivier Séron, Florentin Rengnez, Martin Götz, Eckart Pesel, Hansjörg Scherer

    Abstract: An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one p… ▽ More

    Submitted 1 July, 2015; originally announced July 2015.

    Comments: 13 pages, 8 figures

  17. arXiv:1407.5508  [pdf

    physics.ins-det cond-mat.mes-hall

    Traceable precision pA direct current measurements with the ULCA

    Authors: Hansjörg Scherer, Gerd-Dietmar Willenberg, Dietmar Drung, Martin Götz, Eckart Pesel

    Abstract: A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its ampl… ▽ More

    Submitted 6 August, 2014; v1 submitted 21 July, 2014; originally announced July 2014.

    Comments: 8 pages, 3 figures

  18. arXiv:1406.4662  [pdf

    cond-mat.other physics.ins-det

    Traceable precision generation and measurement of pA direct currents

    Authors: Hansjörg Scherer, Gerd-Dietmar Willenberg, Dietmar Drung, Martin Götz, Eckart Pesel

    Abstract: We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity… ▽ More

    Submitted 18 June, 2014; originally announced June 2014.

    Comments: 2 pages, 1 figure. Contribution (summary paper, to appear in IEEE CPEM 2014 Conference Digest) accepted for presentation on the Conference on Precision Electromagnetic Measurements (CPEM) 2014 in Rio de Janeiro (Brazil), 24-29 August 2014

  19. arXiv:1106.3452  [pdf, other

    physics.med-ph

    Analysis and Optimisation of Pulse Dynamics for Magnetic Stimulation

    Authors: Stefan M. Goetz, Nam C. Truong, Manuel G. Gerhofer, Thomas Weyh, Hans-Georg Herzog

    Abstract: Magnetic stimulation is a standard tool in brain research and many fields of neurology, as well as psychiatry. From a physical perspective, one key aspect of this method is the inefficiency of available setups. Whereas the spatial field properties have been studied rather intensively with coil designs, the dynamics have been neglected almost completely for a long time. Instead, the devices and the… ▽ More

    Submitted 17 June, 2011; originally announced June 2011.

    Comments: 23 pages (including references and appendix), 7 figures