Color-map recommendation for MR relaxometry maps
Authors:
Miha Fuderer,
Barbara Wichtmann,
Fabio Crameri,
Nandita M. deSouza,
Bettina Baeßler,
Vikas Gulani,
Meiyun Wang,
Dirk Poot,
Ruud de Boer,
Matt Cashmore,
Wolter de Graaf,
Kathryn E. Keenan,
Dan Ma,
Carolin Pirkl,
Nico Sollmann,
Sebastian Weingärtner,
Stefano Mandija,
Xavier Golay
Abstract:
Purpose: To harmonize the use of color for MR relaxometry maps and therefore recommend the use of specific color-maps for representing T1 and T2 maps. Methods: Perceptually linearized color-maps were chosen to have similar color settings as those proposed by Griswold et al. in 2018. A Delphi process, polling the opinion of a panel of 81 experts, was used to generate consensus on the suitability of…
▽ More
Purpose: To harmonize the use of color for MR relaxometry maps and therefore recommend the use of specific color-maps for representing T1 and T2 maps. Methods: Perceptually linearized color-maps were chosen to have similar color settings as those proposed by Griswold et al. in 2018. A Delphi process, polling the opinion of a panel of 81 experts, was used to generate consensus on the suitability of these maps. Results: Consensus was reached on the suitability of the logarithm-processed Lipari color-map for T1 and the logarithm-processed Navia color-map for T2. There was consensus on color bars being mandatory and on the use of a specific value indicating invalidity. There was no consensus on whether the ranges should be fixed per anatomy. Conclusion: The authors recommend the use of the logarithm-processed Lipari color map for displaying quantitative T1 maps and R1 maps; likewise, the authors recommend the logarithm-processed Navia color-map for displaying T2, T2*, R2 and R2* maps.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
Time-efficient, high-resolution 3T whole-brain relaxometry using Cartesian 3D MR-STAT with CSF suppression
Authors:
Hongyan Liu,
Edwin Versteeg,
Miha Fuderer,
Oscar van der Heide,
Martin B. Schilder,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Purpose: Current 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain. This study aims at developing a 3D MR-STAT protocol for whole-brain relaxometry that overcomes the challenges posed by CSF-induced ghosting artifacts. Method…
▽ More
Purpose: Current 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain. This study aims at developing a 3D MR-STAT protocol for whole-brain relaxometry that overcomes the challenges posed by CSF-induced ghosting artifacts. Method: We optimized the flip-angle train within the Cartesian 3D MR-STAT framework to achieve two objectives: (1) minimization of the noise level in the reconstructed quantitative maps, and (2) reduction of the CSF-to-white-matter signal ratio to suppress CSF signal and the associated pulsation artifacts. The optimized new sequence was tested on a gel/water-phantom to evaluate the accuracy of the quantitative maps, and on healthy volunteers to explore the effectiveness of the CSF artifact suppression and robustness of the new protocol. Results: A new optimized sequence with both high parameter encoding capability and low CSF intensity was proposed and initially validated in the gel/water-phantom experiment. From in-vivo experiments with five volunteers, the proposed CSF-suppressed sequence shows no CSF ghosting artifacts and overall greatly improved image quality for all quantitative maps compared to the baseline sequence. Statistical analysis indicated low inter-subject and inter-scan variability for quantitative parameters in gray matter and white matter (1.6%-2.4% for T1 and 2.0%-4.6% for T2), demonstrating the robustness of the new sequence. Conclusion: We presented a new 3D MR-STAT sequence with CSF suppression that effectively eliminates CSF pulsation artifacts. The new sequence ensures consistently high-quality, 1mm^3 whole-brain relaxometry within a rapid 5.5-minute scan time.
△ Less
Submitted 22 March, 2024;
originally announced March 2024.
-
A three-dimensional MR-STAT protocol for high-resolution multi-parametric quantitative MRI
Authors:
Hongyan Liu,
Oscar van der Heide,
Edwin Versteeg,
Martijn Froeling,
Miha Fuderer,
Fei Xu,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Magnetic Resonance Spin Tomography in Time-Domain (MR-STAT) is a multiparametric quantitative MR framework, which allows for simultaneously acquiring quantitative tissue parameters such as T1, T2 and proton density from one single short scan. A typical 2D MR-STAT acquisition uses a gradient-spoiled, gradient-echo sequence with a slowly varying RF flip-angle train and Cartesian readouts, and the qu…
▽ More
Magnetic Resonance Spin Tomography in Time-Domain (MR-STAT) is a multiparametric quantitative MR framework, which allows for simultaneously acquiring quantitative tissue parameters such as T1, T2 and proton density from one single short scan. A typical 2D MR-STAT acquisition uses a gradient-spoiled, gradient-echo sequence with a slowly varying RF flip-angle train and Cartesian readouts, and the quantitative tissue maps are reconstructed by an iterative, model-based optimization algorithm. In this work, we design a 3D MR-STAT framework based on previous 2D work, in order to achieve better image SNR, higher though-plan resolution and better tissue characterization. Specifically, we design a 7-minute, high-resolution 3D MR-STAT sequence, and the corresponding two-step reconstruction algorithm for the large-scale dataset. To reduce the long acquisition time, Cartesian undersampling strategies such as SENSE are adopted in our transient-state quantitative framework. To reduce the computational burden, a data splitting scheme is designed for decoupling the 3D reconstruction problem into independent 2D reconstructions. The proposed 3D framework is validated by numerical simulations, phantom experiments and in-vivo experiments. High-quality knee quantitative maps with 0.8 x 0.8 x 1.5mm3 resolution and bilateral lower leg maps with 1.6mm isotropic resolution can be acquired using the proposed 7-minute acquisition sequence and the 3-minute-per-slice decoupled reconstruction algorithm. The proposed 3D MR-STAT framework could have wide clinical applications in the future.
△ Less
Submitted 22 May, 2023;
originally announced May 2023.