A Novel Portable and Wearable Broadband Near-Infrared Spectroscopy Device for In-Vivo Oxygenation and Metabolism Measurements
Authors:
Musa Talati,
Frederic Lange,
Dimitrios Airantzis,
Danial Chitnis,
Temisan Illukwe,
Darshana Gopal,
Paola Pinti,
Niccole Ranaei-Zamani,
Olayinka Kowobari,
Sara Hillman,
Dimitrios Siassakos,
Anna David,
Subhabrata Mitra,
Ilias Tachtsidis
Abstract:
Broadband NIRS (bNIRS) is an extension of fNIRS that provides the same assessment of oxygenation biomarkers along with a valuable marker for oxygen metabolism at a cellular level, the oxidation state of cytochrome-c-oxidase (oxCCO). bNIRS implements many (100s) NIR wavelengths in the full NIR spectrum to address this and provide insight to tissue energetics. To supply these many wavelengths of lig…
▽ More
Broadband NIRS (bNIRS) is an extension of fNIRS that provides the same assessment of oxygenation biomarkers along with a valuable marker for oxygen metabolism at a cellular level, the oxidation state of cytochrome-c-oxidase (oxCCO). bNIRS implements many (100s) NIR wavelengths in the full NIR spectrum to address this and provide insight to tissue energetics. To supply these many wavelengths of light, broadband sources are required, and spectrometers are employed to distinguish power per wavelength. Current multi-channel bNIRS instruments are bulky and only semi-portable due to technological limitations. We propose a design for a bNIRS device that has been miniaturized to allow for portable use. This design leverages the innovations in photonic devices that have created a new line of microspectrometers and broadband NIR high-power LEDs; the Hamamatsu SMD-type spectrometer C14384MA and the Ushio SMBBIR45-1100 LED. This first-of-itskind device, referred to as microCYRIL (after its two predecessors CYRIL and miniCYRIL), has been developed for oxygenation and metabolism measurements with dual channel operation. To verify functionality, concentration changes in oxygenated (HbO2) and deoxygenated (HHb) haemoglobin and oxCCO were successfully tracked during a cuff-induced venous and arterial occlusion.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 20 June, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (191 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 12 July, 2024; v1 submitted 23 May, 2024;
originally announced May 2024.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Physical modeling of ribosomes along messenger RNA: estimating kinetic parameters from ribosome profiling experiments using a ballistic model
Authors:
Carole Chevalier,
Jérôme Dorignac,
Yahaya Ibrahim,
Armelle Choquet,
Alexandre David,
Julie Ripoll,
Eric Rivals,
Frédéric Geniet,
Nils-Ole Walliser,
John Palmeri,
Andrea Parmeggiani,
Jean-Charles Walter
Abstract:
Gene expression consists in the synthesis of proteins from the information encoded on DNA. One of the two main steps of gene expression is the translation of messenger RNA (mRNA) into polypeptide sequences of amino acids. Here, by taking into account mRNA degradation, we model the motion of ribosomes along mRNA with a ballistic model where particles advance along a filament without excluded volume…
▽ More
Gene expression consists in the synthesis of proteins from the information encoded on DNA. One of the two main steps of gene expression is the translation of messenger RNA (mRNA) into polypeptide sequences of amino acids. Here, by taking into account mRNA degradation, we model the motion of ribosomes along mRNA with a ballistic model where particles advance along a filament without excluded volume interactions. Unidirectional models of transport have previously been used to fit the average density of ribosomes obtained by the experimental ribo-sequencing (Ribo-seq) technique. In this case an inverse fit gives access to the kinetic rates: the position-dependent speeds and the entry rate of ribosomes onto mRNA. The degradation rate is not, however, accounted for and experimental data from different experiments are needed to have enough parameters for the fit. Here, we propose an entirely novel experimental setup and theoretical framework consisting in splitting the mRNAs into categories depending on the number of ribosomes from one to four. We solve analytically the ballistic model for a fixed number of ribosomes per mRNA, study the different regimes of degradation, and propose a criteria for the quality of the inverse fit. The proposed method provides a high sensitivity to the mRNA degradation rate. The additional equations coming from using the monosome (single ribosome) and polysome (arbitrary number) ribo-seq profiles enable us to determine all the kinetic rates in terms of the experimentally accessible mRNA degradation rate.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Molecular origin of viscoelasticity in mineralized collagen fibrils
Authors:
Mario Milazzo,
Alessio David,
Gang Seob Jung,
Serena Danti,
Markus J. Buehler
Abstract:
Bone is mineralized tissue constituting the skeletal system, supporting and protecting body organs and tissues. At the molecular level, mineralized collagen fibril is the basic building block of bone tissue, and hence, understanding bone properties down to fundamental tissue structures enables to better identify the mechanisms of structural failures and damages. While efforts have focused on the s…
▽ More
Bone is mineralized tissue constituting the skeletal system, supporting and protecting body organs and tissues. At the molecular level, mineralized collagen fibril is the basic building block of bone tissue, and hence, understanding bone properties down to fundamental tissue structures enables to better identify the mechanisms of structural failures and damages. While efforts have focused on the study of the micro- and macro-scale viscoelasticity related to bone damage and healing based on creep, mineralized collagen has not been explored on a molecular level. We report a study that aims at systematically exploring the viscoelasticity of collagenous fibrils with different mineralization levels. We investigate the dynamic mechanical response upon cyclic and impulsive loads to observe the viscoelastic phenomena from either shear or extensional strains via molecular dynamics. We perform a sensitivity analysis with several key benchmarks: intrafibrillar mineralization percentage, hydration state, and external load amplitude. Our results show a growth of the dynamic moduli with an increase of mineral percentage, pronounced at low strains. When intrafibrillar water is present, the material softens the elastic component but considerably increases its viscosity, especially at high frequencies. This behaviour is confirmed from the material response upon impulsive loads, in which water drastically reduces the relaxation times throughout the input velocity range by one order of magnitude, with respect to the dehydrated counterparts. We find that upon transient loads, water has a major impact on the mechanics of mineralized fibrillar collagen, being able to improve the capability of the tissue to passively and effectively dissipate energy, especially after fast and high-amplitude external loads.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
Observation of long-range carrier diffusion in InGaN quantum wells, and implications from fundamentals to devices
Authors:
Aurelien David
Abstract:
Photoluminescence measurements on high-quality InGaN quantum wells reveal that carriers diffuse laterally to long distances at room temperature, up to tens of microns. This behavior, which shows a pronounced dependence on the excitation density, contrasts with the common expectation of a short diffusion length. The data is well explained by a diffusion model taking into account the full carrier re…
▽ More
Photoluminescence measurements on high-quality InGaN quantum wells reveal that carriers diffuse laterally to long distances at room temperature, up to tens of microns. This behavior, which shows a pronounced dependence on the excitation density, contrasts with the common expectation of a short diffusion length. The data is well explained by a diffusion model taking into account the full carrier recombination dynamics, obtained from time-resolved measurements. These observations have important implications for understanding the high efficiency of III-nitride emitters, but also to properly interpret photoluminescence experiments and to design efficient small-scale devices.
△ Less
Submitted 14 April, 2021;
originally announced April 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Charting the European Course to the High-Energy Frontier
Authors:
U. Amaldi,
E. Aslanides,
R. Barate,
C. Benvenuti,
P. Bloch,
T. Camporesi,
A. David,
D. Denegri,
M. Diemoz,
L. Di Lella,
G. Dissertori,
N. Doble,
J. Dumarchez,
J. Ellis,
J. Engelen,
C. Fabjan,
B. Fuks,
P. Gavillet,
A. Hoecker,
J. Iliopoulos,
P. Innocenti,
W. Kozanecki,
P. Lebrun,
C. Llewellyn Smith,
C. Lourenço
, et al. (28 additional authors not shown)
Abstract:
We review the capabilities of two projects that have been proposed as the next major European facility, for consideration in the upcoming update of the European Strategy for Particle Physics: CLIC and FCC. We focus on their physics potentials and emphasise the key differences between the linear or circular approaches. We stress the uniqueness of the FCC-ee programme for precision electroweak physi…
▽ More
We review the capabilities of two projects that have been proposed as the next major European facility, for consideration in the upcoming update of the European Strategy for Particle Physics: CLIC and FCC. We focus on their physics potentials and emphasise the key differences between the linear or circular approaches. We stress the uniqueness of the FCC-ee programme for precision electroweak physics at the $Z$ peak and the $WW$ threshold, as well as its unequalled statistics for Higgs physics and high accuracy for observing possible new phenomena in Higgs and $Z$ decays, whereas CLIC and FCC-ee offer similar capabilities near the $t \overline t$ threshold. Whilst CLIC offers the possibility of energy upgrades to 1500 and 3000 GeV, FCC-ee paves the way for FCC-hh. The latter offers unique capabilities for making direct or indirect discoveries in a new energy range, and has the highest sensitivity to the self-couplings of the Higgs boson and any anomalous couplings. We consider the FCC programme to be the best option to maintain Europe's place at the high-energy frontier during the coming decades.
△ Less
Submitted 31 December, 2019;
originally announced December 2019.
-
Many-body effects in strongly-disordered III-nitride quantum wells: interplay between carrier localization and Coulomb interaction
Authors:
Aurelien David,
Nathan G. Young,
Michael D. Craven
Abstract:
The joint impact of Anderson localization and many-body interaction is observed in the optical properties of strongly-disordered III-nitride quantum wells, a system where the Coulomb interaction and the fluctuating potential are pronounced effects with similar magnitude. A numerical method is introduced to solve the 6-dimensional coupled Schrodinger equation in the presence of disorder and Coulomb…
▽ More
The joint impact of Anderson localization and many-body interaction is observed in the optical properties of strongly-disordered III-nitride quantum wells, a system where the Coulomb interaction and the fluctuating potential are pronounced effects with similar magnitude. A numerical method is introduced to solve the 6-dimensional coupled Schrodinger equation in the presence of disorder and Coulomb interaction, a challenging numerical task. It accurately reproduces the measured absorption and luminescence dynamics of InGaN quantum wells at room-temperature: absorption spectra reveal the existence of a broadened excitonic peak, and carrier lifetime measurements show that luminescence departs from a conventional bimolecular behavior. These results reveal that luminescence is governed by the interplay between localization and Coulomb interaction, and provide practical insight in the physics of modern light-emitting diodes.
△ Less
Submitted 10 June, 2019;
originally announced June 2019.
-
Quantum efficiency of III-Nitride emitters: evidence for defect-assisted non-radiative recombination and its effect on the green gap
Authors:
Aurelien David,
Nathan G. Young,
Christophe A. Hurni,
Michael D. Craven
Abstract:
Carrier lifetime measurements reveal that, contrary to common expectations, the high-current non-radiative recombination (droop) in III-Nitride light emitters is comprised of two contributions which scale with the cube of the carrier density: an intrinsic recombination --most likely standard Auger scattering-- and an extrinsic recombination which is proportional to the density of point defects. Th…
▽ More
Carrier lifetime measurements reveal that, contrary to common expectations, the high-current non-radiative recombination (droop) in III-Nitride light emitters is comprised of two contributions which scale with the cube of the carrier density: an intrinsic recombination --most likely standard Auger scattering-- and an extrinsic recombination which is proportional to the density of point defects. This second droop mechanism, which hasn't previously been observed, is likely caused by an impurity-assisted Auger process. Further, it is shown that longer-wavelength emitters suffer from higher point defect recombinations, in turn causing an increase in the extrinsic droop process. It is proposed that this effect leads to the green gap, and that point defect reduction is a strategy to both vanquish the green gap and more generally improve quantum efficiency at high current.
△ Less
Submitted 6 April, 2019; v1 submitted 20 November, 2018;
originally announced November 2018.
-
Searching for degenerate Higgs bosons - A profile likelihood ratio method to test for mass-degenerate states in the presence of incomplete data and uncertainties
Authors:
André David,
Jaana Heikkilä,
Giovanni Petrucciani
Abstract:
Using the likelihood ratio test statistic, we present a method which can be employed to test the hypothesis of a single Higgs boson using the matrix of measured signal strengths. This method can be applied in the presence of incomplete data and takes into account uncertainties on the measurements. The p-value against the hypothesis of a single Higgs boson is defined from the expected distribution…
▽ More
Using the likelihood ratio test statistic, we present a method which can be employed to test the hypothesis of a single Higgs boson using the matrix of measured signal strengths. This method can be applied in the presence of incomplete data and takes into account uncertainties on the measurements. The p-value against the hypothesis of a single Higgs boson is defined from the expected distribution of the test statistic, generated using pseudo-experiments. The applicability of the likelihood-based test is demonstrated using numerical examples with uncertainties and missing matrix elements.
△ Less
Submitted 4 February, 2015; v1 submitted 22 September, 2014;
originally announced September 2014.
-
Linearly Dichroic Plasmonic Lens and Hetero-Chiral Structures
Authors:
Grisha Spektor,
Asaf David,
Bergin Gjonaj,
Lior Gal,
Meir Orenstein
Abstract:
We present theoretical and experimental study of plasmonic Hetero-Chiral structures, comprised of constituents with opposite chirality. We devise, simulate and experimentally demonstrate different schemes featuring selective surface plasmon polariton focusing of orthogonal polarization states and standing plasmonic vortex fields.
We present theoretical and experimental study of plasmonic Hetero-Chiral structures, comprised of constituents with opposite chirality. We devise, simulate and experimentally demonstrate different schemes featuring selective surface plasmon polariton focusing of orthogonal polarization states and standing plasmonic vortex fields.
△ Less
Submitted 31 May, 2014;
originally announced June 2014.
-
Structural characterization of PrVO3 epitaxial thin films
Authors:
O. Copie,
H. Rotella,
P. Boullay,
M. Morales,
A. Pautrat,
A David,
B. Mercey,
D. Pravarthana,
I. C. Infante,
P. -E. Janolin,
W. Prellier
Abstract:
Rare earth perovskite oxides constitute a wide family of materials presenting functional proper- ties strongly coupled to their crystalline structure. Here, we report on the experimental results on epitaxial PrVO3 deposited on SrTiO3 single crystal substrates by pulsed laser deposition. By com- bining advanced structural characterization tools, we have observed that the PVO unrelaxed film structur…
▽ More
Rare earth perovskite oxides constitute a wide family of materials presenting functional proper- ties strongly coupled to their crystalline structure. Here, we report on the experimental results on epitaxial PrVO3 deposited on SrTiO3 single crystal substrates by pulsed laser deposition. By com- bining advanced structural characterization tools, we have observed that the PVO unrelaxed film structure grown on STO, is characterized by two kinds of oriented domains whose epitaxial relations are: (i) PrVO3[110]o//SrTiO3[001]c and PrVO3[001]o//SrTiO3[100]c, (ii) PrVO3[110]o//SrTiO3[001]c and PrVO3[001]o//SrTiO3[010]c. We have also measured reciprocal space maps. From these results, we have determined that the PVO film epitaxy on STO imposes a lowering of the PVO structure symmetry from orthorhombic (Pbnm) to monoclinic (P21/m). We show, the nominal strain induced by the substrate being constant, that the obtained film structure depends on both growth oxygen and temperature. Thus, by finely controlling the deposition conditions, we could tune the strain experienced by PrVO3 thin film. These results show an alternative to substrate mismatch as a path to control the strain and structure of PVO films.
△ Less
Submitted 28 March, 2014;
originally announced March 2014.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Study of GEM-like detectors with resistive electrodes for RICH applications
Authors:
A. G. Agocs,
A. Di Mauro,
A. Ben David,
B. Clark,
P. Martinengo,
E. Nappi,
V. Peskov
Abstract:
We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to operate at high gain (~10E5) in many gases including poorly quenched ones, allowing for the adoption of windowless configurations in which the radiator gas is…
▽ More
We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to operate at high gain (~10E5) in many gases including poorly quenched ones, allowing for the adoption of windowless configurations in which the radiator gas is also used in the chamber. Results of systematic studies of the resistive GEMs combined with CsI photocathodes are presented: its quantum efficiency, rate characteristics, long-term stability, etc. On the basis of the obtained results, we believe that the new detector will be a promising candidate for upgrading the ALICE RICH detector
△ Less
Submitted 13 December, 2007;
originally announced December 2007.