Skip to main content

Showing 1–11 of 11 results for author: Camsonne, A

  1. arXiv:2402.00947  [pdf, other

    physics.ins-det

    Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

    Authors: J. Xie, C. Peng, S. Joosten, Z. -E. Meziani, A. Camsonne, M. Jones, S. Malace, E. Kaczanowicz, M. Rehfuss, N. Sparveris, M. Paolone, M. Foley, M. Minot, M. Popecki, Z. W. Zhao

    Abstract: The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Ph… ▽ More

    Submitted 3 July, 2024; v1 submitted 1 February, 2024; originally announced February 2024.

    Comments: 11 pages, 8 figures

  2. arXiv:2210.09048  [pdf, other

    physics.ins-det hep-ex nucl-ex

    ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider

    Authors: ATHENA Collaboration, J. Adam, L. Adamczyk, N. Agrawal, C. Aidala, W. Akers, M. Alekseev, M. M. Allen, F. Ameli, A. Angerami, P. Antonioli, N. J. Apadula, A. Aprahamian, W. Armstrong, M. Arratia, J. R. Arrington, A. Asaturyan, E. C. Aschenauer, K. Augsten, S. Aune, K. Bailey, C. Baldanza, M. Bansal, F. Barbosa, L. Barion , et al. (415 additional authors not shown)

    Abstract: ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e… ▽ More

    Submitted 13 October, 2022; originally announced October 2022.

    Journal ref: JINST 17 (2022) 10, P10019

  3. arXiv:2209.13357  [pdf, other

    nucl-ex hep-ph physics.ins-det

    The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV

    Authors: John Arrington, Jay Benesch, Alexandre Camsonne, Jimmy Caylor, Jian-Ping Chen, Silviu Covrig Dusa, Alexander Emmert, George Evans, Haiyan Gao, J. Ole Hansen, Garth M. Huber, Sylvester Joosten, Vladimir Khachatryan, Nilanga Liyanage, Zein-Eddine Meziani, Michael Nycz, Chao Peng, Michael Paolone, Whit Seay, Paul A. Souder, Nikos Sparveris, Hubert Spiesberger, Ye Tian, Eric Voutier, Junqi Xie , et al. (6 additional authors not shown)

    Abstract: The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit… ▽ More

    Submitted 12 February, 2023; v1 submitted 18 September, 2022; originally announced September 2022.

    Comments: This white paper for the SoLID program at Jefferson Lab was prepared in part as an input to the 2023 NSAC Long Range Planning exercise. To be submitted to J. Phys. G

  4. arXiv:2103.05419  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex nucl-th

    Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report

    Authors: R. Abdul Khalek, A. Accardi, J. Adam, D. Adamiak, W. Akers, M. Albaladejo, A. Al-bataineh, M. G. Alexeev, F. Ameli, P. Antonioli, N. Armesto, W. R. Armstrong, M. Arratia, J. Arrington, A. Asaturyan, M. Asai, E. C. Aschenauer, S. Aune, H. Avagyan, C. Ayerbe Gayoso, B. Azmoun, A. Bacchetta, M. D. Baker, F. Barbosa, L. Barion , et al. (390 additional authors not shown)

    Abstract: This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon… ▽ More

    Submitted 26 October, 2021; v1 submitted 8 March, 2021; originally announced March 2021.

    Comments: 902 pages, 415 authors, 151 institutions

    Report number: BNL-220990-2021-FORE, JLAB-PHY-21-3198, LA-UR-21-20953

    Journal ref: Nucl. Phys. A 1026 (2022) 122447

  5. arXiv:2011.11769  [pdf, other

    physics.ins-det nucl-ex

    Performance of photosensors in a high-rate environment for gas Cherenkov detectors

    Authors: Chao Peng, Junqi Xie, Sylvester Joosten, Zein-Eddine Meziani, Alexandre Camsonne, Mark Jones, Edward Kaczanowicz, Melanie Rehfuss, Nikolaos Sparveris, Michael Paolone, Michael Foley, Michael Minot, Mark Popecki

    Abstract: The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the… ▽ More

    Submitted 3 May, 2022; v1 submitted 23 November, 2020; originally announced November 2020.

    Comments: 16 pages, 11 figures

  6. arXiv:1606.08877  [pdf, ps, other

    physics.acc-ph hep-ex nucl-ex

    Production of highly-polarized positrons using polarized electrons at MeV energies

    Authors: D. Abbott, P. Adderley, A. Adeyemi, P. Aguilera, M. Ali, H. Areti, M. Baylac, J. Benesch, G. Bosson, B. Cade, A. Camsonne, L. S. Cardman, J. Clark, P. Cole, S. Covert, C. Cuevas, O. Dadoun, D. Dale, H. Dong, J. Dumas, E. Fanchini, T. Forest, E. Forman, A. Freyberger, E. Froidefond , et al. (40 additional authors not shown)

    Abstract: The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an… ▽ More

    Submitted 28 June, 2016; originally announced June 2016.

    Comments: 5 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 116 (2016) 214801

  7. arXiv:1601.00251  [pdf, other

    physics.ins-det nucl-ex

    A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

    Authors: A. Rakhman, M. Hafez, S. Nanda, F. Benmokhtar, A. Camsonne, G. D. Cates, M. M. Dalton, G. B. Franklin, M. Friend, R. W. Michaels, V. Nelyubin, D. S. Parno, K. D. Paschke, B. P. Quinn, P. A. Souder, W. A. Tobias

    Abstract: A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi… ▽ More

    Submitted 29 March, 2016; v1 submitted 3 January, 2016; originally announced January 2016.

    Comments: 20 pages, 22 figures, revised version of arXiv:1601.00251v1, submitted to NIMA

  8. Beam Position Reconstruction for the g2p Experiment in Hall A at Jefferson Lab

    Authors: Pengjia Zhu, Kalyan Allada, Trent Allison, Toby Badman, Alexandre Camsonne, Jian-ping Chen, Melissa Cummings, Chao Gu, Min Huang, Jie Liu, John Musson, Karl Slifer, Vincent Sulkosky, Yunxiu Ye, Jixie Zhang, Ryan Zielinski

    Abstract: Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast r… ▽ More

    Submitted 11 September, 2015; originally announced September 2015.

  9. arXiv:1504.07961  [pdf

    physics.acc-ph

    MEIC Design Summary

    Authors: S. Abeyratne, D. Barber, A. Bogacz, P. Brindza, Y. Cai, A. Camsonne, A. Castilla, P. Chevtsov, E. Daly, Y. S. Derbenev, D. Douglas, V. Dudnikov, R. Ent, B. Erdelyi, Y. Filatov, D. Gaskell, J. Grames, J. Guo, L. Harwood, A. Hutton, C. Hyde, K. Jordan, A. Kimber, G. A. Krafft, A. Kondratenko , et al. (30 additional authors not shown)

    Abstract: This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current infor… ▽ More

    Submitted 29 April, 2015; originally announced April 2015.

  10. Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector

    Authors: D. S. Parno, M. Friend, V. Mamyan, F. Benmokhtar, A. Camsonne, G. B. Franklin, K. Paschke, B. Quinn

    Abstract: We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the… ▽ More

    Submitted 24 May, 2013; v1 submitted 15 November, 2012; originally announced November 2012.

    Comments: 6 pages, 7 figures

  11. Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

    Authors: M. Friend, D. Parno, F. Benmokhtar, A. Camsonne, M. Dalton, G. B. Franklin, V. Mamyan, R. Michaels, S. Nanda, V. Nelyubin, K. Paschke, B. Quinn, A. Rakhman, P. Souder, A. Tobias

    Abstract: The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta… ▽ More

    Submitted 24 August, 2011; v1 submitted 15 August, 2011; originally announced August 2011.

    Comments: 16 pages, 15 figures