-
Metrology requirements for the integrated luminosity measurement at ILC
Authors:
Ivan Smiljanić,
Ivanka Božović,
Goran Kačarević,
Mirko Radulović,
Jasna Stevanović
Abstract:
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review a feasibility of the targeted pr…
▽ More
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review a feasibility of the targeted precision of $\mathcal{L}$ at foreseen ILC center-of-mass energies: 91.2 GeV, 250 GeV, 500 GeV and 1 TeV.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Probing CPV mixing in the Higgs sector in VBF at 1 TeV ILC
Authors:
N. Vukašinović,
I. Božović-Jelisavčić,
G. Kačarević,
I. Smiljanić,
I. Vidaković
Abstract:
With the current precision of measurements by the ATLAS and CMS experiments, it cannot be excluded that a SM-like Higgs boson is a CP violating mixture of CP-even and CP-odd states. We explore this possibility here, assuming Higgs boson production in ZZ-fusion, at 1 TeV ILC, with unpolarized beams. The full simulation of SM background and fast simulation of the signal is performed, simulating 8 ab…
▽ More
With the current precision of measurements by the ATLAS and CMS experiments, it cannot be excluded that a SM-like Higgs boson is a CP violating mixture of CP-even and CP-odd states. We explore this possibility here, assuming Higgs boson production in ZZ-fusion, at 1 TeV ILC, with unpolarized beams. The full simulation of SM background and fast simulation of the signal is performed, simulating 8 ab$^{-1}$ of data collected with the ILD detector. We demonstrate that the CP mixing angle $Ψ_{\mathrm{CP}}$ between scalar and pseudoscalar states can be measured with the statistical uncertainty of 3.8 mrad at 68% CL, corresponding to 1.44 $\cdot 10^{-5}$ for the CP parameter $f_\mathrm{CP}$, for the pure scalar state. This is the first result on sensitivity of an $e^{+}e^{-}$ collider to measure $f_\mathrm{CP}$ in the Higgs production vertex in vector boson fusion.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic,
Goran Kacarevic
Abstract:
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accele…
▽ More
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.
△ Less
Submitted 3 July, 2024; v1 submitted 29 April, 2024;
originally announced April 2024.
-
Very forward calorimeters for future electron-positron colliders
Authors:
Ivan Smiljanic
Abstract:
Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. In our concept, two compact calorimeters are foreseen, LumiCal and BeamCal. Both are designed as sandwich calorimeters with very thin sensor planes…
▽ More
Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. In our concept, two compact calorimeters are foreseen, LumiCal and BeamCal. Both are designed as sandwich calorimeters with very thin sensor planes to keep the Molière radius small, facilitating such the measurement of electron showers in the presence of background. Silicon sensor prototypes and dedicated FE ASICs have been developed and produced. The ASICs match the timing and dynamic range requirements. In the recent beam tests, a multi-plane compact prototype was equipped with thin sensor planes fully assembled with the new readout electronics and installed in 1 mm gaps between tungsten plates of one radiation length thickness. The latest status of the calorimeter prototype development will be presented, including selected performance results, obtained in a 5 GeV electron beam at DESY, as well as the expected performance obtained from simulation.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
Measurement of the H to ZZ branching fraction at 350 GeV and 3 TeV CLIC
Authors:
N. Vukašinović,
I. Božović-Jelisavčić,
G. Kačarević,
M. Radulović,
J. Stevanović,
G. Milutinović-Dumbelović,
T. Agatonović-Jovin,
I. Smiljanić
Abstract:
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. I…
▽ More
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. It is shown that the product of the Higgs production cross-section and the branching fraction BR(${H\rightarrow\thinspace ZZ^\ast}$) can be measured with a relative statistical uncertainty of 20% (3.0%) at a centre-of-mass energy of 350 GeV (3 TeV) using semileptonic final states, assuming an integrated luminosity of 1 ab$^{-1}$ (5 ab$^{-1}$).
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
MEASUREMENT OF THE HIGGS BRANCHING RATIO BR($H\rightarrowγγ$) AT 3 TeV CLIC
Authors:
G. Kacarevic,
I. Bozovic Jelisavcic,
N. Vukasinovic,
I. Smiljanic,
M. Radulovic,
J. Stevanovic,
T. Agatonovic Jovin,
G. Milutinovic Dumbelovic
Abstract:
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the meas…
▽ More
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the measured BR($H\rightarrowγγ$), and consequently of the Higgs coupling $g_{Hγγ}$ from the predictions of the Standard Model, may indicate New Physics. The Higgs decay to two photons is thus an interesting probe of the Higgs sector.
This study is performed using simulation of the detector for CLIC and by considering all relevant physics and beam-induced processes in a full reconstruction chain. It is shown that the product of the Higgs production cross-section in $W^+W^-$ fusion and BR($H\rightarrowγγ$) can be measured with a relative statistical uncertainty of 5.5\%, assuming the integrated luminosity of 5 ab$^{-1}$ and unpolarized beams.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Measurement of the Higgs Branching Ration BR($H\rightarrowγγ$) at 3 TeV CLIC
Authors:
G. Kačarević,
Ivanka Božović-Jelisavčić,
Nataša Vukašinović,
Gordana Milutinović-Dumbelović,
Mirko Radulović,
Jasna Stevanović,
Ivan Smiljanić,
Tatjana Agatonović-Jovin
Abstract:
In this paper we address the potential of a 3 TeV center-of-mass energy Compact Linear Collider (CLIC) to measure the Standard Model (SM) Higgs boson decay to two photons. Since photons are massless, they are not coupled to the Higgs boson at the tree level, but they are created in a loop exchange of heavy particles either from the Standard Model or beyond. Any deviation of the effective…
▽ More
In this paper we address the potential of a 3 TeV center-of-mass energy Compact Linear Collider (CLIC) to measure the Standard Model (SM) Higgs boson decay to two photons. Since photons are massless, they are not coupled to the Higgs boson at the tree level, but they are created in a loop exchange of heavy particles either from the Standard Model or beyond. Any deviation of the effective $H\rightarrowγγ$ branching ratio and consequently of the Higgs to photon coupling may indicate New Physics. The Higgs decay to two photons is thus an interesting probe of the Higgs sector, both at the running and future experiments. A similar study has been performed by C. Grefe at 1.4 TeV CLIC, where the statistical uncertainty is determined to be 15\% for an integrated luminosity of 1.5 $ab^{-1}$ with unpolarized beams. \noindent This study is performed using a full simulation of the detector for CLIC and by considering all relevant physics and beam-induced processes in a full reconstruction chain. The measurement is simulated on 5000 samples of pseudo-experiments and the relative statistical uncertainty is extracted from the pull distribution. It is shown that the Higgs production cross-section in $W^+W^-$ fusion times the branching ratio BR($H\rightarrowγγ$) can be measured with a relative statistical accuracy of 8.2\%, assuming an integrated luminosity of 5 $ab^{-1}$ with unpolarized beams.
△ Less
Submitted 18 June, 2021; v1 submitted 14 May, 2021;
originally announced May 2021.
-
Measurement of the H to ZZ branching fraction at 350 GeV and 3 TeV CLIC
Authors:
N. Vukašinović,
I. Božović-Jelisavčić,
I. Smiljanić,
G. Kačarević,
G. Milutinović-Dumbelović,
T. Agatonović-Jovin,
M. Radulović,
J. Stevanović
Abstract:
In this paper we present results of determination of the statistical precision of Higgs branching fraction measurement, for Higgs decay to ZZ$^\ast$ pairs at 3 TeV and 350 GeV CLIC. Measurements are simulated with the CLIC_ILD detector model, taking into consideration all relevant physics and beam-induced background processes. It is shown that the product of the branching fraction BR(…
▽ More
In this paper we present results of determination of the statistical precision of Higgs branching fraction measurement, for Higgs decay to ZZ$^\ast$ pairs at 3 TeV and 350 GeV CLIC. Measurements are simulated with the CLIC_ILD detector model, taking into consideration all relevant physics and beam-induced background processes. It is shown that the product of the branching fraction BR(${H\rightarrow\thinspace ZZ^\ast}$) and the Higgs production cross-section can be measured with a relative statistical uncertainty of 3% (18%) at 3 TeV (350 GeV) center-of-mass energy, using semileptonic final states and assuming integrated luminosity of 5 (1) ab$^{-1}$.
△ Less
Submitted 24 May, 2021; v1 submitted 14 May, 2021;
originally announced May 2021.
-
Probing the CP properties of the Higgs sector at ILC
Authors:
T. Agatonovic Jovin,
I. Bozovic Jelisavcic,
I. Smiljanic,
G. Kacarevic,
N. Vukasinovic,
G. Milutinovic Dumbelovic,
J. Stevanovic,
M. Radulovic,
D. Jeans
Abstract:
The violation of CP symmetry is one of Sakharov's conditions for the matter-antimatter asymmetry of the Universe. Currently known sources of CP violation in the quark and neutrino sectors are insufficient to account for this. Is CP also violated in the Higgs sector? Could the SM-like Higgs boson be a mixture of even and odd CP states of an extended Higgs sector? With what precision could such effe…
▽ More
The violation of CP symmetry is one of Sakharov's conditions for the matter-antimatter asymmetry of the Universe. Currently known sources of CP violation in the quark and neutrino sectors are insufficient to account for this. Is CP also violated in the Higgs sector? Could the SM-like Higgs boson be a mixture of even and odd CP states of an extended Higgs sector? With what precision could such effects be measured at future electron-positron colliders? These questions will be discussed in the light of the latest and ongoing studies at ILC.
△ Less
Submitted 17 May, 2021; v1 submitted 13 May, 2021;
originally announced May 2021.
-
Integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanić,
Ivanka Božović-Jelisavčić,
Goran Kačarević,
Nataša Vukašinović,
Tatjana Agatonović-Jovin,
Gordana Milutinović-Dumbelović,
Jasna Stevanović,
Mirko Radulović
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning, beam-related requirements and physics background.A method of the effective center-of-mass determination from $e^+e^- \to μ^+μ^-$, initially proposed for FCC, is also discussed for the CEPC beams.
△ Less
Submitted 31 January, 2022; v1 submitted 13 May, 2021;
originally announced May 2021.
-
Systematic uncertainties in integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic Jelisavcic,
Goran Kacarevic,
Natasa Vukasinovic,
Ivana Vidakovic,
Vladimir Rekovic
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechani…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams.
△ Less
Submitted 23 November, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
Beam-spread determination for luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic-Jelisavcic,
Goran Kacarevic
Abstract:
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in o…
▽ More
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in order to control the uncertainty of Bhabha count at the level of 0.01%. Here we discuss the method, initially proposed for FCCee, to determine variation of the beam-spread from the measurement of the effective center-of-mass energy in $e^+e^- \to μ^+μ^-$ collisions.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Physics potential for the measurement of ${σ(Hν\barν)\times \text{BR}(H\rightarrowμ^+μ^-)}$ at the 1.4 TeV CLIC collider
Authors:
G. Milutinović-Dumbelović,
I. Božović-Jelisavčić,
C. Grefe,
G. Kačarević,
S. Lukić,
M. Pandurović,
P. Roloff,
I. Smiljanić
Abstract:
The future Compact Linear Collider (CLIC) offers a possibility for a rich precision physics programme, in particular in the Higgs sector through the energy staging. This is the first paper addressing the measurement of the Standard Model Higgs boson decay into two muons at 1.4 TeV CLIC. With respect to similar studies at future linear colliders, this paper includes several novel contributions to t…
▽ More
The future Compact Linear Collider (CLIC) offers a possibility for a rich precision physics programme, in particular in the Higgs sector through the energy staging. This is the first paper addressing the measurement of the Standard Model Higgs boson decay into two muons at 1.4 TeV CLIC. With respect to similar studies at future linear colliders, this paper includes several novel contributions to the statistical uncertainty of the measurement. The later includes the Equivalent Photon Approximation and realistic forward electron tagging based on energy deposition maps in the forward calorimeters, as well as several processes with the Beamstrahlung photons that results in irreducible contribution to the signal. In addition, coincidence of the Bhabha scattering with the signal and background processes is considered, altering the signal selection efficiency. The study is performed using a fully simulated CLIC_ILD detector model. It is shown that the branching ratio for the Higgs decay into a pair of muons BR(${H\rightarrowμ^+μ^-}$) times the Higgs production cross-section in $WW$-fusion $σ(Hν\barν)$ can be measured with 38% statistical accuracy at ${\sqrt{s} =\text{1.4 TeV}}$, assuming an integrated luminosity of 1.5 ab$^{-1}$ with unpolarised beams. If 80% electron beam polarisation is considered, the statistical uncertainty of the measurement is reduced to 25%. Systematic uncertainties are negligible in comparison to the statistical uncertainty.
△ Less
Submitted 21 July, 2015; v1 submitted 16 July, 2015;
originally announced July 2015.
-
Luminosity measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
G. Milutinovic Dumbelovic,
M. Pandurovic,
I. Smiljanic
Abstract:
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced…
▽ More
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.
△ Less
Submitted 21 August, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Correction of beam-beam effects in luminosity measurement at ILC
Authors:
Strahinja Lukić,
Ivan Smiljanić
Abstract:
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently p…
▽ More
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently proposed, collision-frame method relies on the reconstruction of the collision-frame velocity to define the selection function in the collision frame both in experiment and in theory. Thus the luminosity expression is insensitive to the difference between the CM frame of the collision and the lab frame. The collision-frame method is independent of the knowledge of the beam parameters, and it allows an accurate reconstruction of the luminosity spectrum above 80 % of the nominal CM energy. However, it gives no precise infromation about luminosity below 80 % of the nominal CM energy. The compatibility of diverse selection cuts for background reduction with the collision-frame method is addressed.
△ Less
Submitted 4 March, 2013; v1 submitted 29 November, 2012;
originally announced November 2012.
-
Luminosity Measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
H. Abramowicz,
P. Bambade,
T. Jovin,
M. Pandurovic,
B. Pawlik,
C. Rimbault,
I. Sadeh,
I. Smiljanic
Abstract:
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its in…
▽ More
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its integration in the forward region are presented. The impact of several effects contributing to the systematic uncertainty of luminosity measurement is given.
△ Less
Submitted 13 June, 2010;
originally announced June 2010.