Precision and accuracy of acoustospectrographic parameters
- PMID: 8923705
- DOI: 10.1016/0301-5629(96)00105-6
Precision and accuracy of acoustospectrographic parameters
Abstract
Theoretical estimates of the standard deviation (STD) of four acoustospectrographic parameters (the intercept and slope of attenuation and backscatter coefficient) are derived. This derivation expands and corrects existing derivations, and is confirmed using simulations based on the adopted theoretical model. A robust parameter estimation method is applied to various phantom measurements, and to in vivo liver scans of healthy human subjects. The measured STD is higher than the theoretically predicted value, and we investigated four possible factors which explain this discrepancy. First, it is shown that the STD and bias after spectrogram calculation are rather insensitive to changes in windowing function, type, length and overlap. Second, we observed that a diffraction correction spectrogram calibrated on a medium different from the one being measured insufficiently corrects the depth-dependency of the parameters, which affects both precision as well as accuracy. We therefore propose a method that constructs an organ-specific diffraction correction spectrogram from the averaged spectrogram of a set of normal organs. We show that the organ-specific correction does not affect STD even in case of previously unseen acquisitions. Third, we introduce local inhomogeneity, which predicts excess STD due to local variations of the physical parameters within an organ (i.e., intrasubject), and global inhomogeneity, which predicts variations between organs (i.e., intersubject). We conclude that our method of estimating STD predicts normal, in vivo data very well, and propose that the deviation from these estimates is a potential tissue characterization parameter.
Similar articles
-
Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.Ultrason Imaging. 2017 May;39(3):151-171. doi: 10.1177/0161734616674329. Epub 2016 Oct 20. Ultrason Imaging. 2017. PMID: 28425388 Free PMC article.
-
Time domain attenuation estimation method from ultrasonic backscattered signals.J Acoust Soc Am. 2012 Jul;132(1):533-43. doi: 10.1121/1.4728195. J Acoust Soc Am. 2012. PMID: 22779499 Free PMC article.
-
Hybrid spectral domain method for attenuation slope estimation.Ultrasound Med Biol. 2008 Nov;34(11):1808-19. doi: 10.1016/j.ultrasmedbio.2008.04.011. Epub 2008 Jul 14. Ultrasound Med Biol. 2008. PMID: 18621468
-
On the statistics of ultrasonic spectral parameters.Ultrasound Med Biol. 2006 Nov;32(11):1671-85. doi: 10.1016/j.ultrasmedbio.2006.09.002. Ultrasound Med Biol. 2006. PMID: 17112954
-
Statistical framework for ultrasonic spectral parameter imaging.Ultrasound Med Biol. 1997;23(9):1371-82. doi: 10.1016/s0301-5629(97)00200-7. Ultrasound Med Biol. 1997. PMID: 9428136
Cited by
-
Quantitative Ultrasound: Experimental Implementation.Adv Exp Med Biol. 2023;1403:29-42. doi: 10.1007/978-3-031-21987-0_3. Adv Exp Med Biol. 2023. PMID: 37495913
-
Basic concept and clinical applications of quantitative ultrasound (QUS) technologies.J Med Ultrason (2001). 2021 Oct;48(4):391-402. doi: 10.1007/s10396-021-01139-6. Epub 2021 Oct 20. J Med Ultrason (2001). 2021. PMID: 34669072 Free PMC article. Review.
-
Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound.IEEE Trans Ultrason Ferroelectr Freq Control. 2016 Feb;63(2):336-51. doi: 10.1109/TUFFC.2015.2513958. Epub 2016 Jan 8. IEEE Trans Ultrason Ferroelectr Freq Control. 2016. PMID: 26761606 Free PMC article. Review.
-
Task-oriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method.Ultrason Imaging. 2013 Jul;35(3):214-34. doi: 10.1177/0161734613495524. Ultrason Imaging. 2013. PMID: 23858055 Free PMC article.
-
Improved scatterer property estimates from ultrasound backscatter using gate-edge correction and a pseudo-Welch technique.IEEE Trans Ultrason Ferroelectr Freq Control. 2010 Dec;57(12):2828-32. doi: 10.1109/TUFFC.2010.1756. IEEE Trans Ultrason Ferroelectr Freq Control. 2010. PMID: 21156378 Free PMC article.