Improved parameters for unsharp mask filtering of digital chest radiographs
- PMID: 8475301
- DOI: 10.1148/radiology.187.2.8475301
Improved parameters for unsharp mask filtering of digital chest radiographs
Abstract
Observer performance with four unsharp mask filtering algorithms for storage phosphor chest radiographs was compared with that with conventional screen-film radiographs in the detection of three types of simulated lung disease: nodules, fine lines, and micronodule clusters. Previously studied parameter sets (small [1.4-mm] and medium [5-mm] filter masks) and two new parameter sets (large [2.5-cm] and ultralarge [7-cm] masks) were compared by means of receiver operating characteristic analysis. With medium and small masks, nodule detection was inferior to that achieved with other modes. Use of ultralarge masks decreased the detection of lines compared with detection with conventional screen-film radiographs. Although detection of micronodule clusters was worse with digital images than with conventional screen-film radiographs, results with large and ultralarge masks were better than with small masks. Overall, filtering with large masks was best suited for simultaneously matching linear, nodular, and micronodular structures. These results suggest that lesion-specific processing of digital chest images is not necessary.
Similar articles
-
Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology. 1996 Oct;201(1):45-50. doi: 10.1148/radiology.201.1.8816519. Radiology. 1996. PMID: 8816519
-
Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.AJR Am J Roentgenol. 1995 Aug;165(2):269-73. doi: 10.2214/ajr.165.2.7618538. AJR Am J Roentgenol. 1995. PMID: 7618538
-
High frequency edge enhancement in the detection of fine pulmonary lines. Parity between storage phosphor digital images and conventional chest radiography.Invest Radiol. 1989 Sep;24(9):643-6. doi: 10.1097/00004424-198909000-00001. Invest Radiol. 1989. PMID: 2807816
-
Storage phosphor versus screen-film radiography: effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects.Radiology. 1990 Oct;177(1):109-13. doi: 10.1148/radiology.177.1.2399307. Radiology. 1990. PMID: 2399307
-
[Evaluation of an automated adaptive unsharp masking technique in digital chest radiographs].Nihon Igaku Hoshasen Gakkai Zasshi. 1992 Feb 25;52(2):164-71. Nihon Igaku Hoshasen Gakkai Zasshi. 1992. PMID: 1561056 Japanese.
Cited by
-
Quantitative measurement method for possible rib fractures in chest radiographs.Healthc Inform Res. 2013 Sep;19(3):196-204. doi: 10.4258/hir.2013.19.3.196. Epub 2013 Sep 30. Healthc Inform Res. 2013. PMID: 24175118 Free PMC article.
-
Effect of multiscale processing in digital chest radiography on automated detection of lung nodule with a computer assistance system.J Digit Imaging. 2008 Oct;21 Suppl 1(Suppl 1):S164-70. doi: 10.1007/s10278-007-9094-8. Epub 2008 Feb 1. J Digit Imaging. 2008. PMID: 18239963 Free PMC article.
-
Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.Eur Radiol. 2007 Nov;17(11):2934-40. doi: 10.1007/s00330-007-0650-x. Epub 2007 May 10. Eur Radiol. 2007. PMID: 17492289
-
Interactive image enhancement of CR and DR images.J Digit Imaging. 2004 Sep;17(3):189-95. doi: 10.1007/s10278-004-1000-z. Epub 2004 Jun 4. J Digit Imaging. 2004. PMID: 15175930 Free PMC article.
-
Fast adaptive unsharp masking with programmable mediaprocessors.J Digit Imaging. 2003 Jun;16(2):230-9. doi: 10.1007/s10278-003-1650-2. Epub 2003 Oct 20. J Digit Imaging. 2003. PMID: 14564661 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources