Detection of simulated chest lesions: comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography
- PMID: 7892482
- DOI: 10.1148/radiology.195.1.7892482
Detection of simulated chest lesions: comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography
Abstract
Purpose: To compare a high-contrast asymmetric screen-film system with a conventional screen-film combination and storage phosphor radiographs for detection of simulated chest lesions.
Materials and methods: To test the diagnostic performance of these three systems, the authors used three types of simulated lesions that were superimposed over the chests of 10 patients and an anthropomorphic phantom. In the patient and phantom study, a total of 1,350 observations by each of the eight radiologists were analyzed by means of receiver operating characteristics.
Results: In the patient study, mediastinal nodules were better visualized with high-contrast asymmetric screen-film and storage phosphor radiographs compared with the conventional screen-film system. For visualization of pulmonary nodules, the high-contrast asymmetric screen-film system was best. Micronodules were poorly visualized on high-contrast asymmetric screen-film and storage phosphor radiographs, but only in the phantom study.
Conclusion: The high-contrast asymmetric screen-film system combines the advantages of conventional screen-film radiographs with improved visualization of the mediastinum.
Similar articles
-
Phantom study of chest radiography with storage phosphor, selenium, and film-screen systems.Acta Radiol. 1996 May;37(3 Pt 1):332-6. doi: 10.1177/02841851960371P170. Acta Radiol. 1996. PMID: 8845264
-
Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology. 1996 Oct;201(1):45-50. doi: 10.1148/radiology.201.1.8816519. Radiology. 1996. PMID: 8816519
-
[New analog and digital imaging techniques for chest diagnosis--principles--clinical value--economics].Aktuelle Radiol. 1993 Jan;3(1):6-13. Aktuelle Radiol. 1993. PMID: 8448232 Review. German.
-
Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.AJR Am J Roentgenol. 1995 Aug;165(2):269-73. doi: 10.2214/ajr.165.2.7618538. AJR Am J Roentgenol. 1995. PMID: 7618538
-
Chest imaging within the radiology department by means of photostimulable phosphor computed radiography: a review.J Digit Imaging. 1992 May;5(2):67-78. doi: 10.1007/BF03167829. J Digit Imaging. 1992. PMID: 1623042 Review.
Cited by
-
Computed radiography dual energy subtraction: performance evaluation when detecting low-contrast lung nodules in an anthropomorphic phantom.J Digit Imaging. 1999 Feb;12(1):29-33. doi: 10.1007/BF03168624. J Digit Imaging. 1999. PMID: 10036665 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources