Effect of compression paddle tilt correction on volumetric breast density estimation
- PMID: 22842727
- DOI: 10.1088/0031-9155/57/16/5155
Effect of compression paddle tilt correction on volumetric breast density estimation
Abstract
For the acquisition of a mammogram, a breast is compressed between a compression paddle and a support table. When compression is applied with a flexible compression paddle, the upper plate may be tilted, which results in variation in breast thickness from the chest wall to the breast margin. Paddle tilt has been recognized as a major problem in volumetric breast density estimation methods. In previous work, we developed a fully automatic method to correct the image for the effect of compression paddle tilt. In this study, we investigated in three experiments the effect of paddle tilt and its correction on volumetric breast density estimation. Results showed that paddle tilt considerably affected accuracy of volumetric breast density estimation, but that effect could be reduced by tilt correction. By applying tilt correction, a significant increase in correspondence between mammographic density estimates and measurements on MRI was established. We argue that in volumetric breast density estimation, tilt correction is both feasible and essential when mammographic images are acquired with a flexible compression paddle.
Similar articles
-
Technical challenges in generalizing calibration techniques for breast density measurements.Med Phys. 2019 Feb;46(2):679-688. doi: 10.1002/mp.13325. Epub 2019 Jan 11. Med Phys. 2019. PMID: 30525207 Free PMC article.
-
Technical Note: Validation of two methods to determine contact area between breast and compression paddle in mammography.Med Phys. 2017 Aug;44(8):4040-4044. doi: 10.1002/mp.12392. Epub 2017 Jul 10. Med Phys. 2017. PMID: 28569996
-
Volumetric breast density characteristics as determined from digital mammograms.Phys Med Biol. 2012 Nov 21;57(22):7443-57. doi: 10.1088/0031-9155/57/22/7443. Epub 2012 Oct 24. Phys Med Biol. 2012. PMID: 23093428
-
Compression paddle tilt correction in full-field digital mammograms.Phys Med Biol. 2012 Feb 7;57(3):703-15. doi: 10.1088/0031-9155/57/3/703. Epub 2012 Jan 13. Phys Med Biol. 2012. PMID: 22241616
-
Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume.Med Phys. 2009 Dec;36(12):5525-36. doi: 10.1118/1.3253972. Med Phys. 2009. PMID: 20095265 Free PMC article.
Cited by
-
To what extent are objectively measured mammographic imaging techniques associated with compression outcomes.Br J Radiol. 2023 Jun 1;96(1146):20230089. doi: 10.1259/bjr.20230089. Epub 2023 Apr 22. Br J Radiol. 2023. PMID: 37086069 Free PMC article.
-
Technical challenges in generalizing calibration techniques for breast density measurements.Med Phys. 2019 Feb;46(2):679-688. doi: 10.1002/mp.13325. Epub 2019 Jan 11. Med Phys. 2019. PMID: 30525207 Free PMC article.
-
Common genetic variation and novel loci associated with volumetric mammographic density.Breast Cancer Res. 2018 Apr 17;20(1):30. doi: 10.1186/s13058-018-0954-6. Breast Cancer Res. 2018. PMID: 29665850 Free PMC article.
-
Automatic Estimation of Volumetric Breast Density Using Artificial Neural Network-Based Calibration of Full-Field Digital Mammography: Feasibility on Japanese Women With and Without Breast Cancer.J Digit Imaging. 2017 Apr;30(2):215-227. doi: 10.1007/s10278-016-9922-9. J Digit Imaging. 2017. PMID: 27832519 Free PMC article.
-
The Short-Term Effect of Weight Loss Surgery on Volumetric Breast Density and Fibroglandular Volume.Obes Surg. 2017 Apr;27(4):1013-1023. doi: 10.1007/s11695-016-2415-6. Obes Surg. 2017. PMID: 27783370 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical