Compression paddle tilt correction in full-field digital mammograms
- PMID: 22241616
- DOI: 10.1088/0031-9155/57/3/703
Compression paddle tilt correction in full-field digital mammograms
Abstract
During the acquisition of a mammogram the breast is compressed between the compression paddle and the support table. When compression is applied, the upper plate is tilted which results in variation in breast thickness from the chest wall to the breast margin. Variation in breast thickness influences the grey-level values of the image and hampers image analysis, such as volumetric breast density estimation. In this paper, we present and compare two methods that estimate and correct image tilt. The first method estimates tilt from fatty tissue regions. The second method is based on the entropy of the grey-level distribution of the image. Both methods use a classifier that distinguishes fatty areas from dense tissue based on texture features independent of tilt. The tilt correction methods are evaluated by assessing their accuracies in estimating artificial tilts that are added to images that are known to have only a small tilt. On average, both methods are able to estimate the artificial tilt. To the best of our knowledge, this is the first paper that presents and validates tilt correction methods on individual mammograms.
Similar articles
-
Breast image analysis for risk assessment, detection, diagnosis, and treatment of cancer.Annu Rev Biomed Eng. 2013;15:327-57. doi: 10.1146/annurev-bioeng-071812-152416. Epub 2013 May 13. Annu Rev Biomed Eng. 2013. PMID: 23683087 Review.
-
Effect of compression paddle tilt correction on volumetric breast density estimation.Phys Med Biol. 2012 Aug 21;57(16):5155-68. doi: 10.1088/0031-9155/57/16/5155. Epub 2012 Jul 27. Phys Med Biol. 2012. PMID: 22842727
-
Full-field digital mammography compared with screen-film mammography in the detection of breast cancer: rays of light through DMIST or more fog?Breast Cancer Res Treat. 2008 Jan;107(2):157-65. doi: 10.1007/s10549-007-9545-4. Epub 2007 Mar 22. Breast Cancer Res Treat. 2008. PMID: 17377840 Review. No abstract available.
-
Volumetric breast density estimation from full-field digital mammograms.IEEE Trans Med Imaging. 2006 Mar;25(3):273-82. doi: 10.1109/TMI.2005.862741. IEEE Trans Med Imaging. 2006. PMID: 16524084 Clinical Trial.
-
Thickness correction of mammographic images by means of a global parameter model of the compressed breast.IEEE Trans Med Imaging. 2004 Jul;23(7):799-806. doi: 10.1109/TMI.2004.827477. IEEE Trans Med Imaging. 2004. PMID: 15250632
Cited by
-
Technical challenges in generalizing calibration techniques for breast density measurements.Med Phys. 2019 Feb;46(2):679-688. doi: 10.1002/mp.13325. Epub 2019 Jan 11. Med Phys. 2019. PMID: 30525207 Free PMC article.
-
The compressed breast during mammography and breast tomosynthesis: in vivo shape characterization and modeling.Phys Med Biol. 2017 Aug 7;62(17):6920-6937. doi: 10.1088/1361-6560/aa7cd0. Phys Med Biol. 2017. PMID: 28665291 Free PMC article.
-
Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality.Eur Radiol. 2015 Mar;25(3):821-9. doi: 10.1007/s00330-014-3422-4. Epub 2014 Dec 11. Eur Radiol. 2015. PMID: 25504427 Free PMC article. Clinical Trial.
-
Measurement of breast tissue composition with dual energy cone-beam computed tomography: a postmortem study.Med Phys. 2013 Jun;40(6):061902. doi: 10.1118/1.4802734. Med Phys. 2013. PMID: 23718593 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical