Multicenter Study
. 2012 Jun;85(1014):758-64.
doi: 10.1259/bjr/26769569. Epub 2011 Dec 13.

Stand-alone performance of a computer-assisted detection prototype for detection of acute pulmonary embolism: a multi-institutional comparison

Affiliations
Multicenter Study

Stand-alone performance of a computer-assisted detection prototype for detection of acute pulmonary embolism: a multi-institutional comparison

R Wittenberg et al. Br J Radiol. 2012 Jun.

Abstract

Objective: To assess whether the performance of a computer-assisted detection (CAD) algorithm for acute pulmonary embolism (PE) differs in pulmonary CT angiographies acquired at various institutions.

Methods: In this retrospective study, we included 40 consecutive scans with and 40 without PE from 3 institutions (n = 240) using 64-slice scanners made by different manufacturers (General Electric; Philips; Siemens). CAD markers were classified as true or false positive (FP) using independent evaluation by two readers and consultation of a third chest radiologist in discordant cases. Image quality parameters were subjectively scored using 4/5-point scales. Image noise and vascular enhancement were measured. Statistical analysis was done to correlate image quality of the three institutions with CAD stand-alone performance.

Results: Patient groups were comparable with respect to age (p = 0.22), accompanying lung disease (p = 0.12) and inpatient/outpatient ratio (p = 0.67). The sensitivity was 100% (34/34), 97% (37/38) and 92% (33/36), and the specificity was 18% (8/44), 15% (6/41) and 13% (5/39). Neither significantly differed between the institutions (p = 0.21 and p = 0.820, respectively). The mean number of FP findings (4.5, 6.2 and 3.7) significantly varied (p = 0.02 and p = 0.03), but median numbers (2, 3 and 3) were comparable. Image quality parameters were significantly associated with the number of FP findings (p<0.05) but not with sensitivity. After correcting for noise and vascular enhancement, the number of FPs did not significantly differ between the three institutions (p = 0.43).

Conclusions: CAD stand-alone performance is independent of scanner type but strongly related to image quality and thus scanning protocols.

PubMed Disclaimer

Figures

Figure 1
Figure 1
False-positive finding found by computer-assisted detection located in a vein.
Figure 2
Figure 2
False-positive finding found by computer-assisted detection due to low vascular enhancement.

Similar articles

Cited by

References

    1. British Thoracic Society guidelines for the management of suspected acute pulmonary embolism. Thorax 2003;58:470–83 - PMC - PubMed
    1. Cronin P, Weg JG, Kazerooni EA. The role of multidetector computed tomography angiography for the diagnosis of pulmonary embolism. Semin Nucl Med 2008;38:418–31 - PubMed
    1. Remy-Jardin M, Pistolesi M, Goodman LR, Gefter WB, Gottschalk A, Mayo JR, et al. Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 2007;245:315–29 - PubMed
    1. Schaefer-Prokop C, Prokop M. MDCT for the diagnosis of acute pulmonary embolism. Eur Radiol 2005;15(Suppl 4):D37–41 - PubMed
    1. Brunot S, Corneloup O, Latrabe V, Montaudon M, Laurent F. Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 2005;15:2057–63 - PubMed

Publication types