Computer-aided diagnosis with temporal analysis to improve radiologists' interpretation of mammographic mass lesions
- PMID: 20403792
- DOI: 10.1109/TITB.2010.2043296
Computer-aided diagnosis with temporal analysis to improve radiologists' interpretation of mammographic mass lesions
Abstract
The purpose of this study was to evaluate the effect of independent reading with computer-aided diagnosis (CAD) and independent double reading on radiologists' performance to characterize mass lesions on serial mammograms. Six radiologists rated 198 cases, 99 benign and 99 malignant. For each case, the mammograms from two consecutive screening rounds were available. The mass was visible on the prior view in 40% of the cases. Independently, a CAD programe also rated each mass lesion making use of information from prior and current views. The following reading situations were compared: single reading, independent reading with CAD, and independent double reading. Independent reading with CAD was implemented by averaging the scaled ratings from each radiologist and the scaled CAD scores. We implemented independent double reading by averaging the scaled scores from two radiologists. Results were evaluated using receiver-operating characteristic (ROC) methodology and multiple reader multiple case analysis. The average performance, measured as the area under the ROC curve (A(z) value), was 0.80 for the single-reading mode. For independent double reading, the average performance improved to 0.81. This improvement was not significant. For independent interpretation with CAD, the average performance significantly increased to 0.83 (P < 0.05). We conclude that CAD technology with temporal analysis has the potential to help radiologists with the task of discriminating between benign and malignant masses.
Similar articles
-
Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review.BMC Med Imaging. 2012 Jul 24;12:22. doi: 10.1186/1471-2342-12-22. BMC Med Imaging. 2012. PMID: 22827803 Free PMC article. Review.
-
Does the accuracy of single reading with CAD (computer-aided detection) compare with that of double reading?: A review of the literature.Clin Radiol. 2006 Dec;61(12):1023-8. doi: 10.1016/j.crad.2006.09.006. Clin Radiol. 2006. PMID: 17097423 Review.
-
Improvement in radiologists' characterization of malignant and benign breast masses on serial mammograms with computer-aided diagnosis: an ROC study.Radiology. 2004 Oct;233(1):255-65. doi: 10.1148/radiol.2331030432. Epub 2004 Aug 18. Radiology. 2004. PMID: 15317954
-
Computer-aided detection versus independent double reading of masses on mammograms.Radiology. 2003 Apr;227(1):192-200. doi: 10.1148/radiol.2271011962. Epub 2003 Feb 28. Radiology. 2003. PMID: 12616008
-
Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: an ROC study.Radiology. 1999 Sep;212(3):817-27. doi: 10.1148/radiology.212.3.r99au47817. Radiology. 1999. PMID: 10478252
Cited by
-
Deep learning of longitudinal mammogram examinations for breast cancer risk prediction.Pattern Recognit. 2022 Dec;132:108919. doi: 10.1016/j.patcog.2022.108919. Epub 2022 Jul 22. Pattern Recognit. 2022. PMID: 37089470 Free PMC article.
-
A Review of Computer-Aided Breast Cancer Diagnosis Using Sequential Mammograms.Tomography. 2022 Dec 6;8(6):2874-2892. doi: 10.3390/tomography8060241. Tomography. 2022. PMID: 36548533 Free PMC article. Review.
-
Digital subtraction of temporally sequential mammograms for improved detection and classification of microcalcifications.Eur Radiol Exp. 2021 Sep 14;5(1):40. doi: 10.1186/s41747-021-00238-w. Eur Radiol Exp. 2021. PMID: 34519867 Free PMC article.
-
Application of artificial intelligence to the diagnosis and therapy of colorectal cancer.Am J Cancer Res. 2020 Nov 1;10(11):3575-3598. eCollection 2020. Am J Cancer Res. 2020. PMID: 33294256 Free PMC article. Review.
-
Multi-reader multi-case studies using the area under the receiver operator characteristic curve as a measure of diagnostic accuracy: systematic review with a focus on quality of data reporting.PLoS One. 2014 Dec 26;9(12):e116018. doi: 10.1371/journal.pone.0116018. eCollection 2014. PLoS One. 2014. PMID: 25541977 Free PMC article. Review.