An anatomically shaped lower body model for CT scanning of cadaver femurs
- PMID: 20023325
- DOI: 10.1088/0031-9155/55/2/N03
An anatomically shaped lower body model for CT scanning of cadaver femurs
Abstract
Bone specific, CT-based finite element (FE) analyses have great potential to accurately predict the fracture risk of deteriorated bones. However, it has been shown that differences exist between FE-models of femora scanned in a water basin or scanned in situ within the human body, as caused by differences in measured bone mineral densities (BMD). In this study we hypothesized that these differences can be reduced by re-creating the patient CT-conditions by using an anatomically shaped physical model of the lower body. BMD distributions were obtained from four different femora that were scanned under three conditions: (1) in situ within the cadaver body, (2) in a water basin and (3) in the body model. The BMD of the three scanning protocols were compared at two locations: proximally, in the trabecular bone of the femoral head, and in the cortical bone of the femoral shaft. Proximally, no significant differences in BMD were found between the in situ scans and the scans in the body model, whereas the densities from the water basin scans were on average 10.8% lower than in situ. In the femoral shaft the differences between the three scanning protocols were insignificant. In conclusion, the body model better approached the in situ situation than a water basin. Future studies can use this body model to mimic patient situations and to develop protocols to improve the performance of the FE-models in actual patients.
Similar articles
-
Calibration with or without phantom for fracture risk prediction in cancer patients with femoral bone metastases using CT-based finite element models.PLoS One. 2019 Jul 30;14(7):e0220564. doi: 10.1371/journal.pone.0220564. eCollection 2019. PLoS One. 2019. PMID: 31361790 Free PMC article.
-
Cortical bone finite element models in the estimation of experimentally measured failure loads in the proximal femur.Bone. 2012 Oct;51(4):737-40. doi: 10.1016/j.bone.2012.06.026. Epub 2012 Jul 14. Bone. 2012. PMID: 22796418
-
Determination of vertebral and femoral trabecular morphology and stiffness using a flat-panel C-arm-based CT approach.Bone. 2012 Jan;50(1):200-8. doi: 10.1016/j.bone.2011.10.020. Epub 2011 Oct 26. Bone. 2012. PMID: 22057082
-
[Prediction of bone strength using a CT based finite element method].Clin Calcium. 2006 Dec;16(12):2043-51. Clin Calcium. 2006. PMID: 17142936 Review. Japanese.
-
Prediction of strength and strain of the proximal femur by a CT-based finite element method.J Biomech. 2007;40(8):1745-53. doi: 10.1016/j.jbiomech.2006.08.003. Epub 2006 Oct 10. J Biomech. 2007. PMID: 17034798
Cited by
-
Effect of different CT scanners and settings on femoral failure loads calculated by finite element models.J Orthop Res. 2018 Mar 6;36(8):2288-95. doi: 10.1002/jor.23890. Online ahead of print. J Orthop Res. 2018. PMID: 29508905 Free PMC article.
-
In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.Med Eng Phys. 2011 Mar;33(2):164-73. doi: 10.1016/j.medengphy.2010.09.018. Epub 2010 Oct 27. Med Eng Phys. 2011. PMID: 21030287 Free PMC article.
Publication types
MeSH terms