Parameter sensitivity visualization for DTI fiber tracking
- PMID: 19834219
- DOI: 10.1109/TVCG.2009.170
Parameter sensitivity visualization for DTI fiber tracking
Abstract
Fiber tracking of Diffusion Tensor Imaging (DTI) data offers a unique insight into the three-dimensional organisation of white matter structures in the living brain. However, fiber tracking algorithms require a number of user-defined input parameters that strongly affect the output results. Usually the fiber tracking parameters are set once and are then re-used for several patient datasets. However, the stability of the chosen parameters is not evaluated and a small change in the parameter values can give very different results. The user remains completely unaware of such effects. Furthermore, it is difficult to reproduce output results between different users. We propose a visualization tool that allows the user to visually explore how small variations in parameter values affect the output of fiber tracking. With this knowledge the user cannot only assess the stability of commonly used parameter values but also evaluate in a more reliable way the output results between different patients. Existing tools do not provide such information. A small user evaluation of our tool has been done to show the potential of the technique.
Similar articles
-
A Monte Carlo simulation of image misalignment effects in diffusion tensor imaging.Magn Reson Imaging. 2010 Jul;28(6):834-41. doi: 10.1016/j.mri.2010.03.030. Epub 2010 Apr 21. Magn Reson Imaging. 2010. PMID: 20409661
-
A novel interface for interactive exploration of DTI fibers.IEEE Trans Vis Comput Graph. 2009 Nov-Dec;15(6):1433-40. doi: 10.1109/TVCG.2009.112. IEEE Trans Vis Comput Graph. 2009. PMID: 19834218
-
Intersubject variability in the analysis of diffusion tensor images at the group level: fractional anisotropy mapping and fiber tracking techniques.Magn Reson Imaging. 2009 Apr;27(3):324-34. doi: 10.1016/j.mri.2008.07.003. Epub 2008 Aug 12. Magn Reson Imaging. 2009. PMID: 18701228
-
[Visualization of neuronal fiber tracts in white matter based on diffusion tensor].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2006 Aug;23(4):899-902. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2006. PMID: 17002134 Review. Chinese.
-
[Fiber tracking by means of magnetic resonance diffusion tensor imaging].Nihon Rinsho. 2004 Apr;62(4):707-14. Nihon Rinsho. 2004. PMID: 15106343 Review. Japanese.
Cited by
-
A Survey of Colormaps in Visualization.IEEE Trans Vis Comput Graph. 2016 Aug;22(8):2051-69. doi: 10.1109/TVCG.2015.2489649. Epub 2015 Oct 26. IEEE Trans Vis Comput Graph. 2016. PMID: 26513793 Free PMC article.
-
From Quantification to Visualization: A Taxonomy of Uncertainty Visualization Approaches.IFIP Adv Inf Commun Technol. 2012;377:226-249. doi: 10.1007/978-3-642-32677-6_15. IFIP Adv Inf Commun Technol. 2012. PMID: 25663949 Free PMC article.
-
An improved fiber tracking algorithm based on fiber assignment using the continuous tracking algorithm and two-tensor model.Neural Regen Res. 2012 Jul 25;7(21):1667-74. doi: 10.3969/j.issn.1673-5374.2012.21.010. Neural Regen Res. 2012. PMID: 25657708 Free PMC article.
-
Evaluation of the female pelvic floor in pelvic organ prolapse using 3.0-Tesla diffusion tensor imaging and fibre tractography.Eur Radiol. 2012 Dec;22(12):2806-13. doi: 10.1007/s00330-012-2548-5. Epub 2012 Jul 14. Eur Radiol. 2012. PMID: 22797954 Free PMC article.
-
Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor.Eur Radiol. 2011 Jun;21(6):1243-9. doi: 10.1007/s00330-010-2044-8. Epub 2011 Jan 1. Eur Radiol. 2011. PMID: 21197534 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources