[The visibility of a central venous catheter using digital luminescence radiography in intensive care radiology]
- PMID: 1733477
- DOI: 10.1055/s-2008-1032838
[The visibility of a central venous catheter using digital luminescence radiography in intensive care radiology]
Abstract
The aim of the following study was to assess the impact of dose alterations on the detection of catheters. We compared the performance of well-exposed conventional and digital portable chest radiographs in the detection of thin catheters and tested the influences of dose alterations. Portable chest radiographs of 20 patients were obtained with conventional film/screen (FR) and with storage phosphors at 50% (SRL), 100% (SRN), and 250% (SRH) of the conventionally required exposure dose. The region of the mediastinum was subdivided into an average of 18 fields, 50% of which were superimposed with thin catheter segments. ROC analysis of 11,600 observations by 8 readers found only SRH equivalent to FR in catheter visualisation. Performance decreased significantly with SRN and SRL. Detection of low contrast catheters was found to be significantly decreased in storage phosphor radiographs obtained with standard exposure dose. A dose reduction is not feasible with current equipment if performance equivalent to conventional radiography is to be achieved.
Similar articles
-
Detection of monitoring materials on bedside chest radiographs with the most recent generation of storage phosphor plates: dose increase does not improve detection performance.Radiology. 2003 Apr;227(1):216-21. doi: 10.1148/radiol.2271020045. Radiology. 2003. PMID: 12668747 Clinical Trial.
-
[Digital chest x-rays with a selenium detector: a prospective comparison with a conventional film-screen combination].Rofo. 1997 Feb;166(2):101-7. doi: 10.1055/s-2007-1015390. Rofo. 1997. PMID: 9116250 German.
-
[New analog and digital imaging techniques for chest diagnosis--principles--clinical value--economics].Aktuelle Radiol. 1993 Jan;3(1):6-13. Aktuelle Radiol. 1993. PMID: 8448232 Review. German.
-
[Can digital luminescent radiography substitute for conventional x-ray technics in chest radiography?].Rofo. 1990 May;152(5):501-9. doi: 10.1055/s-2008-1046912. Rofo. 1990. PMID: 2160680 Review. German.
-
[Experiences with digital luminescence radiography (DLR) in pediatric radiology].Rofo. 1992 Feb;156(2):107-11. doi: 10.1055/s-2008-1032847. Rofo. 1992. PMID: 1739766 German.
Cited by
-
Support line and tube visibility in chest examinations using computed radiography.J Digit Imaging. 1997 Aug;10(3):126-31. doi: 10.1007/BF03168600. J Digit Imaging. 1997. PMID: 9268908 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous