Impact of hard-copy size on observer performance in digital chest radiography
- PMID: 1609106
- DOI: 10.1148/radiology.184.1.1609106
Impact of hard-copy size on observer performance in digital chest radiography
Abstract
To determine the impact of reduced hard-copy size on diagnostic performance of digital radiography, screen-film chest radiographs were compared with isodose digital storage phosphor radiographs in the detection of simulated nodules, fine pulmonary lines, and micronodular opacities superimposed on the chests of 10 healthy volunteers. Digital radiographs were laser-printed in a full-size conventional format and in image lengths of two-thirds, one-half, and five-elevenths of the conventional format. Eighteen thousand observations by eight radiologists were analyzed by use of receiver operating characteristics. The detectability of lines and micronodular opacities decreased with declining image format size. In the detection of micronodular opacities, only the nearly full-size digital images were equivalent to conventional images. In the detection of linear opacities, reduction of image length by one-half or more reduced performance (analysis of variance, P less than .05). Only for the detection of nodules was no major difference found.
Similar articles
-
Hard Digital Nodules.Skin Appendage Disord. 2017 Jan;2(3-4):100-101. doi: 10.1159/000448252. Epub 2016 Sep 14. Skin Appendage Disord. 2017. PMID: 28232915 Free PMC article. Review. No abstract available.
-
[A systematic review of digital radiography for the screening and recognition of pneumoconiosis].Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2014 May;32(5):327-34. Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2014. PMID: 25169085 Review. Chinese.
-
Digital chest radiography with a solid-state flat-panel x-ray detector: contrast-detail evaluation with processed images printed on film hard copy.Radiology. 2001 Mar;218(3):679-82. doi: 10.1148/radiology.218.3.r01mr27679. Radiology. 2001. PMID: 11230639
-
Digital storage phosphor chest radiography: an ROC study of the effect of 2K versus 4K matrix size on observer performance.Radiology. 2001 Feb;218(2):527-32. doi: 10.1148/radiology.218.2.r01fe26527. Radiology. 2001. PMID: 11161174
-
Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology. 1996 Oct;201(1):45-50. doi: 10.1148/radiology.201.1.8816519. Radiology. 1996. PMID: 8816519
Cited by
-
Does preference influence performance when reading different sizes of cranial computed tomography?J Med Imaging (Bellingham). 2014 Oct;1(3):035503. doi: 10.1117/1.JMI.1.3.035503. Epub 2014 Dec 22. J Med Imaging (Bellingham). 2014. PMID: 26158074 Free PMC article.
-
Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed tomography with cine-mode display.Radiol Phys Technol. 2011 Jan;4(1):13-8. doi: 10.1007/s12194-010-0099-5. Epub 2010 Aug 19. Radiol Phys Technol. 2011. PMID: 20820964
-
Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.Eur Radiol. 2007 Nov;17(11):2934-40. doi: 10.1007/s00330-007-0650-x. Epub 2007 May 10. Eur Radiol. 2007. PMID: 17492289
-
Support line and tube visibility in chest examinations using computed radiography.J Digit Imaging. 1997 Aug;10(3):126-31. doi: 10.1007/BF03168600. J Digit Imaging. 1997. PMID: 9268908 Free PMC article.
-
A digital imaging and communications in medicine (DICOM) print service for chest imaging.J Digit Imaging. 1997 Aug;10(3):120-5. doi: 10.1007/BF03168599. J Digit Imaging. 1997. PMID: 9268907 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources