Interval change analysis to improve computer aided detection in mammography
- PMID: 15996893
- DOI: 10.1016/j.media.2005.03.007
Interval change analysis to improve computer aided detection in mammography
Abstract
We are developing computer aided diagnosis (CAD) techniques to study interval changes between two consecutive mammographic screening rounds. We have previously developed methods for the detection of malignant masses based on features extracted from single mammographic views. The goal of the present work was to improve our detection method by including temporal information in the CAD program. Toward this goal, we have developed a regional registration technique. This technique links a suspicious location on the current mammogram with a corresponding location on the prior mammogram. The novelty of our method is that the search for correspondence is done in feature space. This has the advantage that very small lesions and architectural distortions may be found as well. Following the linking process several features are calculated for the current and prior region. Temporal features are obtained by combining the feature values from both regions. We evaluated the detection performance with and without the use of temporal features on a data set containing 2873 temporal film pairs from 938 patients. There were 589 cases in which the current mammogram contained exactly one malignant mass. Cross validation was used to partition the data set into a train set and a test set. The train set was used for feature selection and classifier training, the test set for classifier evaluation. FROC (free response operating characteristic) analysis showed an improvement in detection performance with the use of temporal features.
Similar articles
-
Deep learning in mammography and breast histology, an overview and future trends.Med Image Anal. 2018 Jul;47:45-67. doi: 10.1016/j.media.2018.03.006. Epub 2018 Mar 26. Med Image Anal. 2018. PMID: 29679847 Review.
-
Bilateral analysis based false positive reduction for computer-aided mass detection.Med Phys. 2007 Aug;34(8):3334-44. doi: 10.1118/1.2756612. Med Phys. 2007. PMID: 17879797 Free PMC article.
-
Temporal change analysis for characterization of mass lesions in mammography.IEEE Trans Med Imaging. 2007 Jul;26(7):945-53. doi: 10.1109/TMI.2007.897392. IEEE Trans Med Imaging. 2007. PMID: 17649908
-
Combining two mammographic projections in a computer aided mass detection method.Med Phys. 2007 Mar;34(3):898-905. doi: 10.1118/1.2436974. Med Phys. 2007. PMID: 17441235
-
Computer-aided detection and diagnosis of breast cancer.Radiol Clin North Am. 2000 Jul;38(4):725-40. doi: 10.1016/s0033-8389(05)70197-4. Radiol Clin North Am. 2000. PMID: 10943274 Review.
Cited by
-
A Review of Computer-Aided Breast Cancer Diagnosis Using Sequential Mammograms.Tomography. 2022 Dec 6;8(6):2874-2892. doi: 10.3390/tomography8060241. Tomography. 2022. PMID: 36548533 Free PMC article. Review.
-
Classifying symmetrical differences and temporal change for the detection of malignant masses in mammography using deep neural networks.J Med Imaging (Bellingham). 2017 Oct;4(4):044501. doi: 10.1117/1.JMI.4.4.044501. Epub 2017 Oct 10. J Med Imaging (Bellingham). 2017. PMID: 29021992 Free PMC article.
-
Quality assurance and training procedures for computer-aided detection and diagnosis systems in clinical use.Med Phys. 2013 Jul;40(7):077001. doi: 10.1118/1.4807642. Med Phys. 2013. PMID: 23822459 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous