Gray scale registration of mammograms using a model of image acquisition
- PMID: 15344475
- DOI: 10.1007/978-3-540-45087-0_34
Gray scale registration of mammograms using a model of image acquisition
Abstract
A parametric technique is proposed to match the pixel-value distributions of two mammograms of the same woman. It can be applied to mammograms of the left and the right breast, or, more effectively, to temporal mammograms, e.g., from two screening rounds. The main reason to match mammograms is to lessen irrelevant differences between images due to acquisition: by varying breast compression, different film types, et cetera. Firstly, a technique like this might reduce the radiologist's efforts to detect relevant differences like abnormal growth in breast tissue that signals breast cancer. Secondly, though not the aim of this study, applications might be found in subtraction radiology or in the computer aided detection of abnormalities in temporal mammograms. Instead of arbitrarily shifting and/or scaling the pixel-values of one image to match the other or directly mapping one histogram to the other, the proposed method is based on general aspects of acquisition. This encompasses (1) breast compression; (2) exposure time; (3) incident radiation intensity; and, (4a) film properties and digitization for screen-film mammograms, or (4b) detector response for unprocessed digital mammograms. The method does not require a priori knowledge about specific settings of acquisition to match histograms; the degrees of freedom are estimated from the pixel-value distributions of the two mammograms themselves. By the method it is possible to match digitized screen-film mammograms (in the next also referred to as analog mammograms) as well as unprocessed digital mammograms in any of the four possible combinations: analog to analog, analog to digital, digital to analog, and digital to digital.
Similar articles
-
Computing mammographic density from a multiple regression model constructed with image-acquisition parameters from a full-field digital mammographic unit.Phys Med Biol. 2007 Aug 21;52(16):4905-21. doi: 10.1088/0031-9155/52/16/013. Epub 2007 Jul 30. Phys Med Biol. 2007. PMID: 17671343 Free PMC article.
-
Linearization of mammograms using parameters derived from noise characteristics.Inf Process Med Imaging. 2005;19:258-69. doi: 10.1007/11505730_22. Inf Process Med Imaging. 2005. PMID: 17354701
-
Effect of computer-aided detection on independent double reading of paired screen-film and full-field digital screening mammograms.AJR Am J Roentgenol. 2007 Feb;188(2):377-84. doi: 10.2214/AJR.05.2207. AJR Am J Roentgenol. 2007. PMID: 17242245
-
Gray-scale and geometric registration of full-field digital and film-screen mammograms.Med Image Anal. 2007 Apr;11(2):146-56. doi: 10.1016/j.media.2006.11.003. Epub 2007 Jan 8. Med Image Anal. 2007. PMID: 17208511
-
Computerized nipple identification for multiple image analysis in computer-aided diagnosis.Med Phys. 2004 Oct;31(10):2871-82. doi: 10.1118/1.1800713. Med Phys. 2004. PMID: 15543797 Free PMC article. Clinical Trial.
Cited by
-
Effect of soft-copy display supported by CAD on mammography screening performance.Eur Radiol. 2006 Jan;16(1):45-52. doi: 10.1007/s00330-005-2878-7. Epub 2005 Aug 25. Eur Radiol. 2006. PMID: 16132926
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical