Comparison of digital and conventional mammography: a ROC study of 270 mammograms
- PMID: 1405832
- DOI: 10.3109/14639239209085015
Comparison of digital and conventional mammography: a ROC study of 270 mammograms
Abstract
Observer performance tests were conducted to study the visibility of malignancies in digital mammography. Detectabilities of tumours and of microcalcifications were studied separately. For this purpose two sets of images were used, one for tumours consisting of 150 mammograms and one for microcalcifications containing 120 mammograms. Images were digitized at a resolution of 2048 x 2048 pixels using a 12-bit CCD camera. Conventional film mammograms were read on a lightbox, whereas digital mammograms were viewed on a high-resolution monitor. Two experienced radiologists read both sets independently, and ranked their judgements about the presence or absence of tumours or microcalcifications on a confidence-rating scale. Results were evaluated using receiver operating characteristic (ROC) analysis. No statistical differences were found between judgements based on conventional and digitized mammography.
Similar articles
-
Comparison of diagnostic accuracy of breast masses using digitized images versus screen-film mammography.Acta Radiol. 2008 Jul;49(6):618-22. doi: 10.1080/02841850802014610. Acta Radiol. 2008. PMID: 18568552
-
Advanced digital mammography.J Digit Imaging. 1998 Aug;11(3 Suppl 1):163-5. doi: 10.1007/BF03168292. J Digit Imaging. 1998. PMID: 9735459 Free PMC article. Review.
-
Interpretation of calcifications in screen/film, digitized, and wavelet-enhanced monitor-displayed mammograms: a receiver operating characteristic study.Acad Radiol. 1996 Apr;3(4):285-93. doi: 10.1016/s1076-6332(96)80240-6. Acad Radiol. 1996. PMID: 8796676
-
Digital mammography. ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications.Invest Radiol. 1987 Jul;22(7):581-9. Invest Radiol. 1987. PMID: 3623862
-
Detecting clustered microcalcifications in the female breast: secondary digitized images versus mammograms.J Belge Radiol. 1992 Jun;75(3):173-8. J Belge Radiol. 1992. PMID: 1400145
Cited by
-
Should previous mammograms be digitised in the transition to digital mammography?Eur Radiol. 2009 Aug;19(8):1890-6. doi: 10.1007/s00330-009-1366-x. Epub 2009 Mar 18. Eur Radiol. 2009. PMID: 19294388
-
Improved sensitivity and specificity of mammograms by producing uniform luminance from viewboxes.J Digit Imaging. 1998 Aug;11(3 Suppl 1):189-91. doi: 10.1007/BF03168301. J Digit Imaging. 1998. PMID: 9735466 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical