Single- and multi-slice spiral computed tomography of the paediatric kidney
- PMID: 12127211
- DOI: 10.1016/s0720-048x(02)00116-x
Single- and multi-slice spiral computed tomography of the paediatric kidney
Abstract
Single- and multi-slice computed tomography (CT) is regarded as the primary imaging tool in traumatology, both in adults and children. For complicated infectious disease and renal tumours, these techniques are recommended only as secondary diagnostic tools. Specifically, multi-slice CT (MSCT) provides excellent spatial resolution, which is a particular advantage for the evaluation of small structures as they are typical in children. However, MSCT offers more information than is required for diagnosis. Therefore, low-dose protocols are necessary for paediatric examinations. The CT dose-index (CTDI(vol)) should not exceed 2 mGy for newborns, 4 mGy for toddlers, 5 mGy for elementary school children, and 8 mGy for adolescents.
Similar articles
-
Computed tomography imaging in children with congenital heart disease: Indications and radiation dose optimization.Arch Cardiovasc Dis. 2016 Feb;109(2):150-7. doi: 10.1016/j.acvd.2015.11.003. Epub 2016 Jan 15. Arch Cardiovasc Dis. 2016. PMID: 26782623 Review.
-
The establishment of computed tomography diagnostic reference levels in Portugal.Radiat Prot Dosimetry. 2014;158(3):307-17. doi: 10.1093/rpd/nct226. Epub 2013 Sep 15. Radiat Prot Dosimetry. 2014. PMID: 24043875
-
Effect of tube current on diagnostic image quality in paediatric cerebral multidetector CT images.Br J Radiol. 2009 Apr;82(976):313-20. doi: 10.1259/bjr/24404354. Epub 2009 Feb 2. Br J Radiol. 2009. PMID: 19188246
-
Low-dose spiral CT: applicability to paediatric chest imaging.Pediatr Radiol. 1999 Aug;29(8):565-9. doi: 10.1007/s002470050648. Pediatr Radiol. 1999. PMID: 10415177
-
[Diagnosis of kidney diseases in children].Vestn Rentgenol Radiol. 1995 Jul-Aug;(4):32-5. Vestn Rentgenol Radiol. 1995. PMID: 8571532 Review. Russian. No abstract available.
Cited by
-
Discordant findings on dimercaptosuccinic acid scintigraphy in children with multi-detector row computed tomography-proven acute pyelonephritis.Korean J Pediatr. 2011 May;54(5):212-8. doi: 10.3345/kjp.2011.54.5.212. Epub 2011 May 31. Korean J Pediatr. 2011. PMID: 21829413 Free PMC article.
-
Multidetector CT of the kidney.Eur Radiol. 2006 Nov;16(11):2603-11. doi: 10.1007/s00330-006-0212-7. Epub 2006 Mar 28. Eur Radiol. 2006. PMID: 16568265 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical